메뉴 건너뛰기




Volumn 32, Issue 1, 2009, Pages 26-29

Evaluation of effective energy for QA and QC: Measurement of half-value layer using radiochromic film density

Author keywords

Effective energy; Half value layer; Quality assurance; Quality control; Radiochromic film

Indexed keywords

ABSORBED DOSE; CALIBRATION CURVES; COEFFICIENT OF DETERMINATIONS; EFFECTIVE ENERGY; FILM DENSITIES; HALF-VALUE LAYER; RADIOCHROMIC FILM; SINGLE STRIPS;

EID: 65349111235     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03178625     Document Type: Article
Times cited : (19)

References (10)
  • 2
    • 18144411652 scopus 로고    scopus 로고
    • Reflection spectrometry analysis of irradiated GAFCHROMIC XR type R radiochromic films
    • Cheung, T., Butson, M.J. and Yu, P.K.N., Reflection spectrometry analysis of irradiated GAFCHROMIC XR type R radiochromic films, Appl. Radiat. Isot., 63(1):127-9, 2005.
    • (2005) Appl. Radiat. Isot , vol.63 , Issue.1 , pp. 127-129
    • Cheung, T.1    Butson, M.J.2    Yu, P.K.N.3
  • 3
    • 65349190867 scopus 로고    scopus 로고
    • International Specialty Products website. Available at:, 2006
    • International Specialty Products website. Available at: www.ispcorp.com (2006).
  • 4
    • 85024949992 scopus 로고    scopus 로고
    • Dosimetric evaluation of GAFCHROMIC XR type T and XR type R films
    • Dini, S.A., Koona, R.A., Ashburn, J.R. and Ali, S.M., Dosimetric evaluation of GAFCHROMIC XR type T and XR type R films, Am. Coll. Med. Phys., 6(1):114-134, 2005.
    • (2005) Am. Coll. Med. Phys , vol.6 , Issue.1 , pp. 114-134
    • Dini, S.A.1    Koona, R.A.2    Ashburn, J.R.3    Ali, S.M.4
  • 5
    • 22544486853 scopus 로고    scopus 로고
    • XR type-R radiochromic film X-ray energy response
    • Butson, M.J., Cheung, T. and Yu, P.K.N., XR type-R radiochromic film X-ray energy response, Phys. Med. Biol., 50(15):195-199, 2005.
    • (2005) Phys. Med. Biol , vol.50 , Issue.15 , pp. 195-199
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.N.3
  • 6
    • 27644471150 scopus 로고    scopus 로고
    • Weak energy dependence of EBT GAFCHROMIC film dose response in the 50 kVp-10 MVp X-ray range
    • Butson, M.J., Cheung, T. and Yu, P.K.N., Weak energy dependence of EBT GAFCHROMIC film dose response in the 50 kVp-10 MVp X-ray range, Appl. Radiat. Isot., 64(1):60-2, 2006.
    • (2006) Appl. Radiat. Isot , vol.64 , Issue.1 , pp. 60-62
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.N.3
  • 7
    • 26244462962 scopus 로고    scopus 로고
    • Post-irradiation colouration of GAFCHROMIC EBT radiochromic film
    • Cheung, T., Butson, M.J. and Yu, P.K.N., Post-irradiation colouration of GAFCHROMIC EBT radiochromic film, Phys. Med. Biol., 50:281-5, 2005.
    • (2005) Phys. Med. Biol , vol.50 , pp. 281-285
    • Cheung, T.1    Butson, M.J.2    Yu, P.K.N.3
  • 8
    • 17844380569 scopus 로고    scopus 로고
    • A study of GAFCHROMIC XR type R film response with reflective-type densitometers and economical flatbed scanners
    • Thomas, G., Chu, R.Y. and Rabe, F., A study of GAFCHROMIC XR type R film response with reflective-type densitometers and economical flatbed scanners, J. Appl. Clin. Med. Phys., 4:307-14, 2003.
    • (2003) J. Appl. Clin. Med. Phys , vol.4 , pp. 307-314
    • Thomas, G.1    Chu, R.Y.2    Rabe, F.3
  • 9
    • 33750197979 scopus 로고    scopus 로고
    • Scanning orientation effects on GAFCHROMIC EBT film dosimetry
    • Butson, M.J., Cheung, T. and Yu, P.K.N., Scanning orientation effects on GAFCHROMIC EBT film dosimetry, Australas. Phys. Eng. Sci. Med., 29(3):281-4, 2006.
    • (2006) Australas. Phys. Eng. Sci. Med , vol.29 , Issue.3 , pp. 281-284
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.