메뉴 건너뛰기




Volumn 113, Issue 10, 2009, Pages 3080-3087

Water confined in cement pastes as a probe of cement microstructure evolution

Author keywords

[No Author keywords available]

Indexed keywords

CALCIUM; DIFFERENTIAL SCANNING CALORIMETRY; GELATION; HYDRATES; HYDRATION; INFRARED DEVICES; INFRARED SPECTROSCOPY; LIQUIDS; MICROSTRUCTURE; OIL WELL CEMENTING; SILICATE MINERALS; SPECTROSCOPIC ANALYSIS; TEMPERATURE MEASURING INSTRUMENTS; THERMOGRAPHY (TEMPERATURE MEASUREMENT); ZEOLITES;

EID: 65249165498     PISSN: 15206106     EISSN: None     Source Type: Journal    
DOI: 10.1021/jp808754t     Document Type: Article
Times cited : (54)

References (57)
  • 3
    • 84906411006 scopus 로고    scopus 로고
    • We adopt the well-accepted cement chemistry notation where: C ) C3S, S ) SiO2 and H H2O. Within this notation the tricalcium silicate is abbreviated as CaO, dicalcium silicate is C2S, and the calcium silicate hydrated phase becomes C-S-H.
    • We adopt the well-accepted cement chemistry notation where: C ) C3S, S ) SiO2 and H ) H2O. Within this notation the tricalcium silicate is abbreviated as CaO, dicalcium silicate is C2S, and the calcium silicate hydrated phase becomes C-S-H.
  • 18
  • 20
    • 84906367733 scopus 로고    scopus 로고
    • The very small feature present at -5 ?C in the cooling thermogram registered after 1 day is probably due to the well-known bleeding phenomenon.
    • The very small feature present at -5 ?C in the cooling thermogram registered after 1 day is probably due to the well-known bleeding phenomenon.
  • 41
    • 84906411007 scopus 로고    scopus 로고
    • The standard deviation on each value is about 1, so values below 1% are meaningless and can be considered zero
    • The standard deviation on each value is about (1%, so values below 1% are meaningless and can be considered zero.
  • 45
    • 84906396521 scopus 로고    scopus 로고
    • It is important to note that the hexagonal ice spectrum (C) significantly differs from that of the liquid water, especially at low temperature. For this reason, apart from the curve, due to the Ca(OH)2, the wavenumbers of the Gaussian curves describing it do not correspond to those of the R, and γ curves.
    • It is important to note that the hexagonal ice spectrum (C) significantly differs from that of the liquid water, especially at low temperature. For this reason, apart from the curve, due to the Ca(OH)2, the wavenumbers of the Gaussian curves describing it do not correspond to those of the R, and γ curves.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.