메뉴 건너뛰기




Volumn , Issue , 2008, Pages

On-line fault diagnostics in operating three-phase induction motors by the active and reactive power media

Author keywords

[No Author keywords available]

Indexed keywords

AIR-GAP ECCENTRICITIES; FAULT CONDITIONS; FAULT DIAGNOSTICS; POWER SIGNATURES; THREE-PHASE INDUCTION MOTORS;

EID: 65249128647     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICELMACH.2008.4800063     Document Type: Conference Paper
Times cited : (14)

References (10)
  • 1
    • 0035388083 scopus 로고    scopus 로고
    • Squirrel-cage rotor options for ac induction motors
    • July/Aug
    • A. H. Bonnett, et al, "Squirrel-cage rotor options for ac induction motors," IEEE Trans. on Ind. Applicat., vol. 37, July/Aug. 2001, pp. 1197-1209.
    • (2001) IEEE Trans. on Ind. Applicat , vol.37 , pp. 1197-1209
    • Bonnett, A.H.1
  • 2
    • 0022910464 scopus 로고
    • Rotor failures in squirrel-cage induction motors
    • Nov/Dec
    • A. H. Bonnett, et al, "Rotor failures in squirrel-cage induction motors," IEEE Trans. on Ind. Applicat., vol. 22, Nov/Dec. 1986, pp. 1165-1173.
    • (1986) IEEE Trans. on Ind. Applicat , vol.22 , pp. 1165-1173
    • Bonnett, A.H.1
  • 3
    • 29244467991 scopus 로고    scopus 로고
    • Condition monitoring and fault diagnosis of electrical motors - A review
    • Sept
    • S. Nandi, H. A. Toliyat, and X. Li, "Condition monitoring and fault diagnosis of electrical motors - A review," IEEE Trans. on Energy Conver., vol. 20, no 4, Sept. 2005, pp. 719-729.
    • (2005) IEEE Trans. on Energy Conver , vol.20 , Issue.4 , pp. 719-729
    • Nandi, S.1    Toliyat, H.A.2    Li, X.3
  • 4
    • 0029478162 scopus 로고
    • Analysis of airgap flux, current and vibration signals as a function of the combination of static and dynamic airgap eccentricity in 3-phase induction machines
    • D. Dorrell, W. Thomson and S. Roach, "Analysis of airgap flux, current and vibration signals as a function of the combination of static and dynamic airgap eccentricity in 3-phase induction machines", Conf. Rec. IEEE-IAS Annu. Meeting, 1995.
    • (1995) Conf. Rec. IEEE-IAS Annu. Meeting
    • Dorrell, D.1    Thomson, W.2    Roach, S.3
  • 5
    • 0034297416 scopus 로고    scopus 로고
    • A review of induction motors signature analysis as medium for fault detection
    • October
    • M. E. H. Benbouzid, "A review of induction motors signature analysis as medium for fault detection," IEEE Trans. on Ind. Elec., vol. 47, October 2000, pp.984-993.
    • (2000) IEEE Trans. on Ind. Elec , vol.47 , pp. 984-993
    • Benbouzid, M.E.H.1
  • 6
    • 0026370158 scopus 로고
    • On-line detection of airgap eccentricity in 3- phase induction motors, by Park's vector approach
    • Public, Sept
    • A. J. M. Cardoso et al., "On-line detection of airgap eccentricity in 3- phase induction motors, by Park's vector approach," IEE 5th Int. Conf. Elect. Mach. Drives, London, UK, IEE Conf. Public. no 341, Sept. 1991.
    • (1991) IEE 5th Int. Conf. Elect. Mach. Drives, London, UK, IEE Conf , Issue.341
    • Cardoso, A.J.M.1
  • 7
    • 65249143684 scopus 로고    scopus 로고
    • M. Drif, and A. J. M. Cardoso, Instantaneous real power signature analysis as a tool for airgap eccentricity diagnostics in three-phase induction motors, ICEM 2006, Chania, Greece, 2-5 Sept. 2006, 6p.
    • M. Drif, and A. J. M. Cardoso, "Instantaneous real power signature analysis as a tool for airgap eccentricity diagnostics in three-phase induction motors," ICEM 2006, Chania, Greece, 2-5 Sept. 2006, 6p.
  • 8
    • 50049119461 scopus 로고    scopus 로고
    • Rotor cage fault diagnostics in threephase induction motors, by the instantaneous non-active power signature analysis
    • Vigo, Spain, 4-7 June, 6p
    • M. Drif and A. J. M. Cardoso, "Rotor cage fault diagnostics in threephase induction motors, by the instantaneous non-active power signature analysis," ISIE 2007, Vigo, Spain, 4-7 June 2007, 6p.
    • (2007) ISIE 2007
    • Drif, M.1    Cardoso, A.J.M.2
  • 9
    • 0031273217 scopus 로고    scopus 로고
    • Evaluation and implementation of a system to eliminate arbitrary load effects in current-based monitoring of induction machines
    • Nov/Dec
    • R. Schoen and T. Habetler, "Evaluation and implementation of a system to eliminate arbitrary load effects in current-based monitoring of induction machines IEEE Trans. on Ind. Applicat., vol. 33, Nov/Dec. 1997, pp. 1571-1577.
    • (1997) IEEE Trans. on Ind. Applicat , vol.33 , pp. 1571-1577
    • Schoen, R.1    Habetler, T.2
  • 10
    • 0036747148 scopus 로고    scopus 로고
    • Performance analysis of a three phase induction motor under mixed eccentricity
    • Sept
    • S. Nandi, R. M. Bharadwaj, and H. A. Toliyat, "Performance analysis of a three phase induction motor under mixed eccentricity", IEEE Trans. on Energy Conver., vol. 17, no 3, pp. 392-399, Sept. 2002.
    • (2002) IEEE Trans. on Energy Conver , vol.17 , Issue.3 , pp. 392-399
    • Nandi, S.1    Bharadwaj, R.M.2    Toliyat, H.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.