메뉴 건너뛰기




Volumn 119, Issue 4, 2009, Pages 740-745

Disturbance of vestibular function attributable to cochlear implantation in children

Author keywords

Cochlear implant (CI); Vestibular evoked myogenic potential (VEMP); Vestibuleocular reflex (vor)

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BODY POSTURE; CHILD; CLINICAL ARTICLE; COCHLEA PROSTHESIS; COHORT ANALYSIS; CORNEA REFLEX; DISEASE SEVERITY; FEMALE; HEARING LOSS; HUMAN; INNER EAR; MALE; OUTCOME ASSESSMENT; PEDIATRICS; PRESCHOOL CHILD; PREVALENCE; PRIORITY JOURNAL; REFLEX; SCHOOL CHILD; STABILOGRAPHY; SURGICAL TECHNIQUE; TERTIARY HEALTH CARE; VESTIBULAR DISORDER; VESTIBULAR EVOKED MYOGENIC POTENTIAL; VESTIBULAR FUNCTION; VESTIBULE OCULAR REFLEX; WEAKNESS; IMPLANTATION; VESTIBULAR TEST; VESTIBULOOCULAR REFLEX;

EID: 65249117647     PISSN: 0023852X     EISSN: None     Source Type: Journal    
DOI: 10.1002/lary.20121     Document Type: Article
Times cited : (89)

References (27)
  • 1
    • 0023876994 scopus 로고
    • The biologic safety of the Cochlear Corporation multipleelectrode intracochlear implant
    • Webb RL, Clark GM, Shepherd RK, Franz BK, Pyman BC. The biologic safety of the Cochlear Corporation multipleelectrode intracochlear implant. Am J Otol 1988; 9:8-13.
    • (1988) Am J Otol , vol.9 , pp. 8-13
    • Webb, R.L.1    Clark, G.M.2    Shepherd, R.K.3    Franz, B.K.4    Pyman, B.C.5
  • 2
    • 0029081795 scopus 로고
    • Success of children with cochlear implants in mainstream educational settings
    • Nevins ME, Chute PM. Success of children with cochlear implants in mainstream educational settings. Ann Otol Rhinol Laryngol Suppl 1995; 166:100-102.
    • (1995) Ann Otol Rhinol Laryngol Suppl , vol.166 , pp. 100-102
    • Nevins, M.E.1    Chute, P.M.2
  • 3
    • 0028970961 scopus 로고
    • The risk of vestibular function loss after intracochlear implantation
    • Huygen PL, Hinderink JB, van den Broek P., et al. The risk of vestibular function loss after intracochlear implantation. Acta Otolaryngol Suppl 1995; 520 (Pt 2) :270-272.
    • (1995) Acta Otolaryngol Suppl , vol.520 , Issue.PART 2 , pp. 270-272
    • Huygen, P.L.1    Hinderink, J.B.2    van den Broek, P.3
  • 4
    • 0029061290 scopus 로고
    • Vestibular effects associated with implantation of a multiple channel cochlear prosthesis
    • Brey RH, Facer GW, Trine MB, Lynn SG, Peterson AM, Suman VJ. Vestibular effects associated with implantation of a multiple channel cochlear prosthesis. Am J Otol 1995; 16:424-430.
    • (1995) Am J Otol , vol.16 , pp. 424-430
    • Brey, R.H.1    Facer, G.W.2    Trine, M.B.3    Lynn, S.G.4    Peterson, A.M.5    Suman, V.J.6
  • 10
    • 0036782405 scopus 로고    scopus 로고
    • Histopathologic changes in the vestibule after cochlear implantation
    • Tien HC, Linthicum FH Jr. Histopathologic changes in the vestibule after cochlear implantation. Otolaryngol Head Neck Surg 2002; 127:260-264.
    • (2002) Otolaryngol Head Neck Surg , vol.127 , pp. 260-264
    • Tien, H.C.1    Linthicum Jr., F.H.2
  • 11
    • 29444443812 scopus 로고    scopus 로고
    • Histopathology of the peripheral vestibular system after cochlear implantation in the human
    • Handzel O., Burgess BJ, Nadol JB Jr. Histopathology of the peripheral vestibular system after cochlear implantation in the human. Otol Neurotol 2006; 27:57-64.
    • (2006) Otol Neurotol , vol.27 , pp. 57-64
    • Handzel, O.1    Burgess, B.J.2    Nadol Jr., J.B.3
  • 15
    • 31544482194 scopus 로고    scopus 로고
    • Vestibular-evoked myogenic potentials in cochlear implant children
    • Jin Y., Nakamura M., Shinjo Y., Kaga K. Vestibular-evoked myogenic potentials in cochlear implant children. Acta Otolaryngol 2006; 126:164-169.
    • (2006) Acta Otolaryngol , vol.126 , pp. 164-169
    • Jin, Y.1    Nakamura, M.2    Shinjo, Y.3    Kaga, K.4
  • 16
    • 42049123895 scopus 로고    scopus 로고
    • Loss of saccular function after cochlear implantation: The diagnostic impact of intracochlear electrically elicited vestibular evoked myogenic potentials
    • Basta D., Todt I., Goepel F., Ernst A. Loss of saccular function after cochlear implantation: the diagnostic impact of intracochlear electrically elicited vestibular evoked myogenic potentials. Audiol Neurootol 2008; 13:187-192.
    • (2008) Audiol Neurootol , vol.13 , pp. 187-192
    • Basta, D.1    Todt, I.2    Goepel, F.3    Ernst, A.4
  • 21
    • 40349091579 scopus 로고    scopus 로고
    • Scala tympani cochleostomy I: Results of a survey
    • Adunka OF, Buchman CA. Scala tympani cochleostomy I: results of a survey. Laryngoscope 2007; 117:2187-2194.
    • (2007) Laryngoscope , vol.117 , pp. 2187-2194
    • Adunka, O.F.1    Buchman, C.A.2
  • 23
    • 34547733379 scopus 로고    scopus 로고
    • Anatomy of the round window and hook region of the cochlea with implications for cochlear implantation and other endocochlear surgical procedures
    • Li PM, Wang H., Northrop C., Merchant SN, Nadol JB Jr. Anatomy of the round window and hook region of the cochlea with implications for cochlear implantation and other endocochlear surgical procedures. Otol Neurotol 2007; 28:641-648.
    • (2007) Otol Neurotol , vol.28 , pp. 641-648
    • Li, P.M.1    Wang, H.2    Northrop, C.3    Merchant, S.N.4    Nadol Jr, J.B.5
  • 24
    • 38649123749 scopus 로고    scopus 로고
    • A true minimally invasive approach for cochlear implantation: High accuracy in cranial base navigation through flat-panel-based volume computed tomography
    • Majdani O., Bartling SH, Leinung M., et al. A true minimally invasive approach for cochlear implantation: high accuracy in cranial base navigation through flat-panel-based volume computed tomography. Otol Neurotol 2008; 29:120-123.
    • (2008) Otol Neurotol , vol.29 , pp. 120-123
    • Majdani, O.1    Bartling, S.H.2    Leinung, M.3
  • 25
    • 0027248538 scopus 로고
    • Intracochlear placement of cochlear implant electrodes in soft surgery technique]
    • Lehnhardt E. [Intracochlear placement of cochlear implant electrodes in soft surgery technique]. Hno 1993; 41:356-359.
    • (1993) Hno , vol.41 , pp. 356-359
    • Lehnhardt, E.1
  • 26
    • 0030754832 scopus 로고    scopus 로고
    • Cochlear implant soft surgery: Fact or fantasy?
    • Cohen NL. Cochlear implant soft surgery: fact or fantasy? Otolaryngol Head Neck Surg 1997; 117:214-216.
    • (1997) Otolaryngol Head Neck Surg , vol.117 , pp. 214-216
    • Cohen, N.L.1
  • 27
    • 27144448107 scopus 로고    scopus 로고
    • Displacement of electrodes of a cochlear implant into the vestibular system: Intra-and postoperative electrophysiological analyses
    • Pau H., Parker A., Sanli H., Gibson WP. Displacement of electrodes of a cochlear implant into the vestibular system: intra-and postoperative electrophysiological analyses. Acta Otolaryngol 2005; 125:1116-1118.
    • (2005) Acta Otolaryngol , vol.125 , pp. 1116-1118
    • Pau, H.1    Parker, A.2    Sanli, H.3    Gibson, W.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.