메뉴 건너뛰기




Volumn 46, Issue 4, 2009, Pages 643-658

Spatial resolution of the Stereo PIV technique

Author keywords

[No Author keywords available]

Indexed keywords

MISALIGNMENT ERRORS; MODULATION TRANSFER FUNCTIONS; PERFORMANCE ASSESSMENTS; REAL IMAGES; SPATIAL RESOLUTIONS; STEREO PIV; THREE-DIMENSIONAL DISPLACEMENTS;

EID: 65049090305     PISSN: 07234864     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00348-008-0589-y     Document Type: Article
Times cited : (28)

References (18)
  • 1
    • 33746829113 scopus 로고    scopus 로고
    • Analysis of interpolation schemes for image deformation methods in PIV: Effect of noise on the accuracy and spatial resolution
    • T Astarita 2006 Analysis of interpolation schemes for image deformation methods in PIV: effect of noise on the accuracy and spatial resolution Exp Fluids 40 977 987
    • (2006) Exp Fluids , vol.40 , pp. 977-987
    • Astarita, T.1
  • 2
    • 0035446917 scopus 로고    scopus 로고
    • Back-projection algorithm with misalignment corrections for 2D3C stereoscopic PIV
    • S Coudert JP Schon 2001 Back-projection algorithm with misalignment corrections for 2D3C stereoscopic PIV Meas Sci Technol 12 1371 1381
    • (2001) Meas Sci Technol , vol.12 , pp. 1371-1381
    • Coudert, S.1    Schon, J.P.2
  • 3
    • 0003716008 scopus 로고    scopus 로고
    • Comparison between warping and mapping methods on a Stereoscopic 2D3C DPIV system with scheimpflug conditions
    • Rouen, 29-31 May 2000
    • Coudert S, Westerweel J (2000) Comparison between warping and mapping methods on a Stereoscopic 2D3C DPIV system with Scheimpflug conditions. In: EuroMech 411 colloquium, Rouen, 29-31 May 2000
    • (2000) EuroMech 411 Colloquium
    • Coudert, S.1    Westerweel, J.2
  • 4
    • 7044239436 scopus 로고    scopus 로고
    • Investigation of the measurement accuracy of stereo particle image velocimetry
    • R Fei W Merzkirch 2004 Investigation of the measurement accuracy of stereo particle image velocimetry Exp Fluids 37 559 565
    • (2004) Exp Fluids , vol.37 , pp. 559-565
    • Fei, R.1    Merzkirch, W.2
  • 5
    • 2942670271 scopus 로고    scopus 로고
    • PIV optimization for the study of turbulent flow using spectral analysis
    • JM Foucaut J Carlier M Stanislas 2004 PIV optimization for the study of turbulent flow using spectral analysis Meas Sci Technol 15 1046 1058
    • (2004) Meas Sci Technol , vol.15 , pp. 1046-1058
    • Foucaut, J.M.1    Carlier, J.2    Stanislas, M.3
  • 6
    • 0031366643 scopus 로고    scopus 로고
    • Three-dimensional particle image velocimetry: Experimental error analysis of digital angular stereoscopic system
    • N Lawson J Wu 1997 Three-dimensional particle image velocimetry: experimental error analysis of digital angular stereoscopic system Meas Sci Technol 8 1455 1464
    • (1997) Meas Sci Technol , vol.8 , pp. 1455-1464
    • Lawson, N.1    Wu, J.2
  • 8
    • 0000152525 scopus 로고    scopus 로고
    • Stereoscopic particle image velocimetry
    • A Prasad 2000 Stereoscopic particle image velocimetry Exp Fluids 29 103 116
    • (2000) Exp Fluids , vol.29 , pp. 103-116
    • Prasad, A.1
  • 9
    • 0000946197 scopus 로고
    • Scheimpflug stereocamera for particle image velocimetry in liquid flows
    • A Prasad K Jensen 1995 Scheimpflug stereocamera for particle image velocimetry in liquid flows Appl Opt 34 7092 7099
    • (1995) Appl Opt , vol.34 , pp. 7092-7099
    • Prasad, A.1    Jensen, K.2
  • 11
    • 24144473677 scopus 로고    scopus 로고
    • S-PIV comparative assessment: Image dewarping + misalignment correction and pinhole + geometric projection
    • F Scarano L David M Bsibsi D Calluaud 2005 S-PIV comparative assessment: image dewarping + misalignment correction and pinhole + geometric projection Exp Fluids 39 257 266
    • (2005) Exp Fluids , vol.39 , pp. 257-266
    • Scarano, F.1    David, L.2    Bsibsi, M.3    Calluaud, D.4
  • 12
    • 0031386326 scopus 로고    scopus 로고
    • Distortion compensation for generalized stereoscopic particle image velocimetry
    • S Soloff R Adrian Z Liu 1997 Distortion compensation for generalized stereoscopic particle image velocimetry Meas Sci Technol 8 1441 1454
    • (1997) Meas Sci Technol , vol.8 , pp. 1441-1454
    • Soloff, S.1    Adrian, R.2    Liu, Z.3
  • 14
    • 0023397578 scopus 로고
    • A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses
    • Tsai RY (1987) A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE J Rob Autom 4:RA-3
    • (1987) IEEE J Rob Autom , vol.4
    • Tsai, R.Y.1
  • 16
    • 24144452497 scopus 로고    scopus 로고
    • Stereo-PIV using self-calibration on particle images
    • B Wieneke 2005 Stereo-PIV using self-calibration on particle images Exp Fluids 39 267 280
    • (2005) Exp Fluids , vol.39 , pp. 267-280
    • Wieneke, B.1
  • 17
    • 0031354164 scopus 로고    scopus 로고
    • Stereoscopic digital particle image velocimetry for application in wind tunnel flows
    • C Willert 1997 Stereoscopic digital particle image velocimetry for application in wind tunnel flows Meas Sci Technol 8 1465 1479
    • (1997) Meas Sci Technol , vol.8 , pp. 1465-1479
    • Willert, C.1
  • 18
    • 33745478445 scopus 로고    scopus 로고
    • Assessment of camera models for use in planar velocimetry calibration
    • C Willert 2006 Assessment of camera models for use in planar velocimetry calibration Exp Fluids 41 135 143
    • (2006) Exp Fluids , vol.41 , pp. 135-143
    • Willert, C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.