-
1
-
-
0036829409
-
PET diagnostic accuracy: Improvement with in-line PET-CT system-initial results
-
Hany TF, Steinert HC, Goerres GW, et al. PET diagnostic accuracy: improvement with in-line PET-CT system-initial results. Radiology 2002; 225:575-81.
-
(2002)
Radiology
, vol.225
, pp. 575-581
-
-
Hany, T.F.1
Steinert, H.C.2
Goerres, G.W.3
-
2
-
-
34547510320
-
Pitfalls in PET/CT interpretation. Q
-
Cook GJ. Pitfalls in PET/CT interpretation. Q J Nucl Med Mol Imaging 2007; 51:235-43.
-
(2007)
J Nucl Med Mol Imaging
, vol.51
, pp. 235-243
-
-
Cook, G.J.1
-
3
-
-
0032616268
-
Pitfalls in oncologic diagnosis with FDG PET imaging: Physiologic and benign variants
-
Shreve PD, Anzai Y, Wahl RL. Pitfalls in oncologic diagnosis with FDG PET imaging: physiologic and benign variants. Radiographics 1999; 19:61-77.
-
(1999)
Radiographics
, vol.19
, pp. 61-77
-
-
Shreve, P.D.1
Anzai, Y.2
Wahl, R.L.3
-
4
-
-
42549127476
-
-
Quirce PR, Banzo MI, Jimenez-Bonilla JF, et al. Potential sources of diagnostic pitfall and variants in FDG-PET/CT. Rev Esp Med Nucl 2008; 27:130-59. 5 Sureshbabu W, Mawlawi O. PET/CT imaging artifacts. J Nucl Med Technol 2005; 33:156-61.
-
Quirce PR, Banzo MI, Jimenez-Bonilla JF, et al. Potential sources of diagnostic pitfall and variants in FDG-PET/CT. Rev Esp Med Nucl 2008; 27:130-59. 5 Sureshbabu W, Mawlawi O. PET/CT imaging artifacts. J Nucl Med Technol 2005; 33:156-61.
-
-
-
-
5
-
-
64949115175
-
-
Shanghai: Shanghai Medical College Publishing House;
-
Zhou KR, Chen ZW. MRI imaging of body. Shanghai: Shanghai Medical College Publishing House; 2000.p. 113-25.
-
(2000)
MRI imaging of body
, pp. 113-125
-
-
Zhou, K.R.1
Chen, Z.W.2
-
6
-
-
34250170177
-
The reduction of artifacts due to metal hip implants in CT-attenuation corrected PET images from hybrid PET/CT scanners
-
Kennedy JA, Israel O, Frenkel A, et al. The reduction of artifacts due to metal hip implants in CT-attenuation corrected PET images from hybrid PET/CT scanners. Med Biol Eng Comput 2007; 45:553-62.
-
(2007)
Med Biol Eng Comput
, vol.45
, pp. 553-562
-
-
Kennedy, J.A.1
Israel, O.2
Frenkel, A.3
-
7
-
-
0037294323
-
Artifacts at PET and PET/CT caused by metallic hip prosthetic material
-
Gerhard W, Goerres MD, Sibylle I, et al. Artifacts at PET and PET/CT caused by metallic hip prosthetic material. Radiology 2003; 226:577.
-
(2003)
Radiology
, vol.226
, pp. 577
-
-
Gerhard, W.1
Goerres, M.D.2
Sibylle, I.3
-
8
-
-
0037361752
-
Initial experience with oral contrast in PET/CT: Phantom and clinical studies
-
Cohade C, Osman M, Nakamoto Y, et al. Initial experience with oral contrast in PET/CT: phantom and clinical studies. J Nucl Med 2003; 44:412-6.
-
(2003)
J Nucl Med
, vol.44
, pp. 412-416
-
-
Cohade, C.1
Osman, M.2
Nakamoto, Y.3
-
9
-
-
0037655094
-
Dual-modality PET/CT imaging: The effect of respiratory motion on combined image quality in clinical oncology
-
Beyer T, Antoch G, Blodgett T, et al. Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology. Eur J Nucl Med 2003; 30:588-96.
-
(2003)
Eur J Nucl Med
, vol.30
, pp. 588-596
-
-
Beyer, T.1
Antoch, G.2
Blodgett, T.3
-
10
-
-
4544221611
-
The CT motion quantitation of lung lesions and its impact on PET-measured SUVs
-
Yusuf E, Erdi YE, Sadek A, et al. The CT motion quantitation of lung lesions and its impact on PET-measured SUVs. J Nucl Med 2004; 45:1287-92.
-
(2004)
J Nucl Med
, vol.45
, pp. 1287-1292
-
-
Yusuf, E.1
Erdi, Y.E.2
Sadek, A.3
-
11
-
-
0037884881
-
Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT
-
Osman MM, Cohade C, Nakamoto Y, et al. Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT. Eur J Nucl Med Mol Imaging 2003; 30:603-6.
-
(2003)
Eur J Nucl Med Mol Imaging
, vol.30
, pp. 603-606
-
-
Osman, M.M.1
Cohade, C.2
Nakamoto, Y.3
-
13
-
-
34250688790
-
-
Bacharach SL. PET/CT attenuation correction: breathing lessons. J Nucl Med 2007; 48: 677-9.
-
Bacharach SL. PET/CT attenuation correction: breathing lessons. J Nucl Med 2007; 48: 677-9.
-
-
-
-
14
-
-
0002952451
-
CT-based attenuation correction: The effects of imaging with the arms in the field of view
-
P
-
Carney J, Townsend DW, Kinahan PE, et al. CT-based attenuation correction: the effects of imaging with the arms in the field of view. J Nucl Med 2001; 42(suppl): 56-7P.
-
(2001)
J Nucl Med
, vol.42
, Issue.SUPPL.
, pp. 56-57
-
-
Carney, J.1
Townsend, D.W.2
Kinahan, P.E.3
-
15
-
-
33750683776
-
Evaluation of a new CT truncation correction algorithm for accurate quantification of PET/CT images
-
413P
-
Mawlawi O, Pan T, Cody DD, et al. Evaluation of a new CT truncation correction algorithm for accurate quantification of PET/CT images. J Nucl Med 2004; 45(suppl):413P.
-
(2004)
J Nucl Med
, vol.45
, Issue.SUPPL.
-
-
Mawlawi, O.1
Pan, T.2
Cody, D.D.3
-
16
-
-
0036835805
-
Glucose uptake, glucose trasporter GLUT4, and glycolytic enzymes in brown adipose tissue from rats adapted to a high protein diet
-
Kawashita N, Brito M, Brito S, et al. Glucose uptake, glucose trasporter GLUT4, and glycolytic enzymes in brown adipose tissue from rats adapted to a high protein diet. Metabolism 2002; 51:1501-5.
-
(2002)
Metabolism
, vol.51
, pp. 1501-1505
-
-
Kawashita, N.1
Brito, M.2
Brito, S.3
-
17
-
-
0036384894
-
Brown adipose tissue: A factor to consider in symmetrical tracer uptake in the neck and upper chest region
-
Hany TF, Gharehpapagh E, Kamel EM, et al. Brown adipose tissue: a factor to consider in symmetrical tracer uptake in the neck and upper chest region. Eur J Nucl Med Mol Imaging 2002; 29:1393-8.
-
(2002)
Eur J Nucl Med Mol Imaging
, vol.29
, pp. 1393-1398
-
-
Hany, T.F.1
Gharehpapagh, E.2
Kamel, E.M.3
|