-
1
-
-
0000471837
-
Vibrations of partially filled cylindrical tanks with ring-stiffeners and flexible bottom
-
Amabili M., Païdoussis M.P., and Lakis A.A. Vibrations of partially filled cylindrical tanks with ring-stiffeners and flexible bottom. Journal of Sound and Vibration 213 (1998) 259-299
-
(1998)
Journal of Sound and Vibration
, vol.213
, pp. 259-299
-
-
Amabili, M.1
Païdoussis, M.P.2
Lakis, A.A.3
-
3
-
-
0025450307
-
Shake table test of cylindrical water tanks in base-isolated structures
-
Chalhoub M.S., and Kelly J.M. Shake table test of cylindrical water tanks in base-isolated structures. ASCE Journal of Engineering Mechanics 116 (1990) 1451-1472
-
(1990)
ASCE Journal of Engineering Mechanics
, vol.116
, pp. 1451-1472
-
-
Chalhoub, M.S.1
Kelly, J.M.2
-
4
-
-
8644286736
-
Seismic response of base-isolated liquid storage tanks considering fluid-structure-soil interaction in time domain
-
Cho K.H., Kim M.K., Lim Y.M., and Cho S.Y. Seismic response of base-isolated liquid storage tanks considering fluid-structure-soil interaction in time domain. Soil Dynamics and Earthquake Engineering 24 (2004) 839-852
-
(2004)
Soil Dynamics and Earthquake Engineering
, vol.24
, pp. 839-852
-
-
Cho, K.H.1
Kim, M.K.2
Lim, Y.M.3
Cho, S.Y.4
-
11
-
-
1242343815
-
Response of base-isolated liquid storage tanks
-
Jadhav M.B., and Jangid R.S. Response of base-isolated liquid storage tanks. Shock and Vibration 11 (2004) 33-45
-
(2004)
Shock and Vibration
, vol.11
, pp. 33-45
-
-
Jadhav, M.B.1
Jangid, R.S.2
-
12
-
-
33745960571
-
Response of base-isolated liquid storage tanks to near-fault motions
-
Jadhav M.B., and Jangid R.S. Response of base-isolated liquid storage tanks to near-fault motions. Structural Engineering and Mechanics 23 (2006) 615-634
-
(2006)
Structural Engineering and Mechanics
, vol.23
, pp. 615-634
-
-
Jadhav, M.B.1
Jangid, R.S.2
-
14
-
-
0029412995
-
Pseudodynamic test for evaluation of seismic performance of base-isolated liquid storage tanks
-
Kim N.S., and Lee D.G. Pseudodynamic test for evaluation of seismic performance of base-isolated liquid storage tanks. Engineering Structures 17 (1995) 198-208
-
(1995)
Engineering Structures
, vol.17
, pp. 198-208
-
-
Kim, N.S.1
Lee, D.G.2
-
15
-
-
0036817730
-
Seismic analysis of base-isolated liquid storage tanks using the BE-FE-BE coupling technique
-
Kim M.K., Lim Y.M., Cho S.Y., Cho K.H., and Lee K.W. Seismic analysis of base-isolated liquid storage tanks using the BE-FE-BE coupling technique. Soil Dynamics and Earthquake Engineering 22 (2002) 1151-1158
-
(2002)
Soil Dynamics and Earthquake Engineering
, vol.22
, pp. 1151-1158
-
-
Kim, M.K.1
Lim, Y.M.2
Cho, S.Y.3
Cho, K.H.4
Lee, K.W.5
-
16
-
-
0027448274
-
Seismic coupled modeling of axisymmetric tanks containing liquid
-
Lay K.S. Seismic coupled modeling of axisymmetric tanks containing liquid. ASCE Journal of Engineering Mechanics 119 (1993) 1747-1761
-
(1993)
ASCE Journal of Engineering Mechanics
, vol.119
, pp. 1747-1761
-
-
Lay, K.S.1
-
17
-
-
0028763004
-
Vibration studies of base-isolated liquid storage tanks
-
Liang B., and Tang J.-X. Vibration studies of base-isolated liquid storage tanks. Computers and Structures 52 (1994) 1051-1059
-
(1994)
Computers and Structures
, vol.52
, pp. 1051-1059
-
-
Liang, B.1
Tang, J.-X.2
-
18
-
-
33645778761
-
Simplified seismic analysis procedures for elevated tanks considering fluid-structure-soil interaction
-
Livaoǧlu R., and Doganǧün A. Simplified seismic analysis procedures for elevated tanks considering fluid-structure-soil interaction. Journal of Fluids and Structures 22 (2006) 421-439
-
(2006)
Journal of Fluids and Structures
, vol.22
, pp. 421-439
-
-
Livaoǧlu, R.1
Doganǧün, A.2
-
19
-
-
0030954235
-
Method for seismic base-isolation of liquid-storage tanks
-
Malhotra P.K. Method for seismic base-isolation of liquid-storage tanks. ASCE Journal of Structural Engineering 123 (1997) 113-116
-
(1997)
ASCE Journal of Structural Engineering
, vol.123
, pp. 113-116
-
-
Malhotra, P.K.1
-
26
-
-
0036642426
-
Seismic response of liquid storage tanks isolated by sliding bearings
-
Shrimali M.K., and Jangid R.S. Seismic response of liquid storage tanks isolated by sliding bearings. Engineering Structures 24 (2002) 909-921
-
(2002)
Engineering Structures
, vol.24
, pp. 909-921
-
-
Shrimali, M.K.1
Jangid, R.S.2
-
28
-
-
64949155264
-
Mechanical models for tanks containing two liquids. Argonne National Laboratory
-
Report No. ANL/RE/CP-80722, pp
-
Tang, Y., 1994. Mechanical models for tanks containing two liquids. Argonne National Laboratory, Report No. ANL/RE/CP-80722, pp. 1-13.
-
(1994)
, pp. 1-13
-
-
Tang, Y.1
-
31
-
-
0012104321
-
Seismic response and design of liquid storage tanks: guidelines for the seismic design of oil and gas pipeline systems
-
Veletsos A.S., and Tang Y. Seismic response and design of liquid storage tanks: guidelines for the seismic design of oil and gas pipeline systems. ASCE Technical Council on Lifeline Earthquake Engineering (1984) 443-461
-
(1984)
ASCE Technical Council on Lifeline Earthquake Engineering
, pp. 443-461
-
-
Veletsos, A.S.1
Tang, Y.2
|