-
1
-
-
24644485953
-
Impaired forearm rotation after tension-band-wiring fixation of olecranon fractures
-
Candal-Couto J.J., Williams J.R., and Sanderson P.L. Impaired forearm rotation after tension-band-wiring fixation of olecranon fractures. J Orthop Trauma 19 (2005) 480-482
-
(2005)
J Orthop Trauma
, vol.19
, pp. 480-482
-
-
Candal-Couto, J.J.1
Williams, J.R.2
Sanderson, P.L.3
-
2
-
-
0016540242
-
Tension band wiring: a method to prevent "backing out" of the Kirschner wire
-
Chaplin D.M. Tension band wiring: a method to prevent "backing out" of the Kirschner wire. Injury 7 (1975) 57-59
-
(1975)
Injury
, vol.7
, pp. 57-59
-
-
Chaplin, D.M.1
-
3
-
-
0015686712
-
Fractures of the olecranon in adults: classification and management
-
Coton C.L. Fractures of the olecranon in adults: classification and management. Injury 5 (1973) 121-129
-
(1973)
Injury
, vol.5
, pp. 121-129
-
-
Coton, C.L.1
-
4
-
-
0026437990
-
Operative treatment of olecranon nonunion
-
Danziger M.B., and Healy W.L. Operative treatment of olecranon nonunion. J Orthop Trauma 6 (1992) 290-293
-
(1992)
J Orthop Trauma
, vol.6
, pp. 290-293
-
-
Danziger, M.B.1
Healy, W.L.2
-
5
-
-
0024444583
-
Post-traumatic proximal radio-ulnar synostosis
-
Failla J., Amadio O., and Morrey B. Post-traumatic proximal radio-ulnar synostosis. J Bone Joint Surg Am 71A (1989) 1208-1213
-
(1989)
J Bone Joint Surg Am
, vol.71 A
, pp. 1208-1213
-
-
Failla, J.1
Amadio, O.2
Morrey, B.3
-
6
-
-
0033770378
-
AO tension-band osteosynthesis of displaced olecranon frectures
-
Finsen V., Lingaas P.S., and Storro S. AO tension-band osteosynthesis of displaced olecranon frectures. Orthopedics 23 (2000) 1069-1072
-
(2000)
Orthopedics
, vol.23
, pp. 1069-1072
-
-
Finsen, V.1
Lingaas, P.S.2
Storro, S.3
-
7
-
-
0033957222
-
Operative treatment of nonunion about the elbow
-
Gallay S.H., and McKee M.D. Operative treatment of nonunion about the elbow. Clin Orthop 370 (2000) 87-101
-
(2000)
Clin Orthop
, vol.370
, pp. 87-101
-
-
Gallay, S.H.1
McKee, M.D.2
-
8
-
-
0034222840
-
Olecranon fractures: Treatment options
-
Hak D.J., and Golladay G.J. Olecranon fractures: Treatment options. J Am Acad Orthop Surg 8 (2000) 266-275
-
(2000)
J Am Acad Orthop Surg
, vol.8
, pp. 266-275
-
-
Hak, D.J.1
Golladay, G.J.2
-
9
-
-
0021690434
-
Elbow function following tension band fixation of displaced fractures of the olecranon
-
Holdsworth B.J., and Mossad M.M. Elbow function following tension band fixation of displaced fractures of the olecranon. Injury 16 (1984) 182-187
-
(1984)
Injury
, vol.16
, pp. 182-187
-
-
Holdsworth, B.J.1
Mossad, M.M.2
-
10
-
-
0019431055
-
Olecranon fractures: A review of 100 cases
-
Horne J.G., and Tanzer T.L. Olecranon fractures: A review of 100 cases. J Trauma 21 (1981) 469-472
-
(1981)
J Trauma
, vol.21
, pp. 469-472
-
-
Horne, J.G.1
Tanzer, T.L.2
-
11
-
-
0031894533
-
Posttraumatic heterotopic ossification about the elbow
-
Ilahi O.A., Strausser D.W., and Gabel G.T. Posttraumatic heterotopic ossification about the elbow. Orthopedics 21 (1998) 263-268
-
(1998)
Orthopedics
, vol.21
, pp. 263-268
-
-
Ilahi, O.A.1
Strausser, D.W.2
Gabel, G.T.3
-
12
-
-
0022497793
-
Drawbacks of traction-absorbing wiring (TAW) in displaced fractures of the olecranon
-
Jensen C.M., and Olsen B.B. Drawbacks of traction-absorbing wiring (TAW) in displaced fractures of the olecranon. Injury 17 (1986) 174-175
-
(1986)
Injury
, vol.17
, pp. 174-175
-
-
Jensen, C.M.1
Olsen, B.B.2
-
13
-
-
0022631661
-
Olecranon fractures treated with AO screw and tension bands
-
Johnson R.P., Roetker A., and Schab J.P. Olecranon fractures treated with AO screw and tension bands. Orthopedics 9 (1986) 66-68
-
(1986)
Orthopedics
, vol.9
, pp. 66-68
-
-
Johnson, R.P.1
Roetker, A.2
Schab, J.P.3
-
14
-
-
0015396262
-
Muscle pedicle bone grafting of long bones by osteoperiosteal decortication
-
Judet P.R. Muscle pedicle bone grafting of long bones by osteoperiosteal decortication. Clin Orthop Relat Res 87 (1972) 74-80
-
(1972)
Clin Orthop Relat Res
, vol.87
, pp. 74-80
-
-
Judet, P.R.1
-
15
-
-
0038560248
-
Internal fixation for fractures about the elbow
-
Jupiter J.B. Internal fixation for fractures about the elbow. Oper Tech Orthop 4 (1994) 31-48
-
(1994)
Oper Tech Orthop
, vol.4
, pp. 31-48
-
-
Jupiter, J.B.1
-
16
-
-
0036780086
-
Fratcures of the olecranon: a 15- to 25-year follow-up of 73 patients
-
Karlsson M.K., Hasserius R., Karlsson C., Besjakov J., and Josefsson P.O. Fratcures of the olecranon: a 15- to 25-year follow-up of 73 patients. Clin Orthop 403 (2002) 205-212
-
(2002)
Clin Orthop
, vol.403
, pp. 205-212
-
-
Karlsson, M.K.1
Hasserius, R.2
Karlsson, C.3
Besjakov, J.4
Josefsson, P.O.5
-
17
-
-
0042849085
-
Comparison of tension-band and figure-of-eight wiring techniques for treatment of olecranon fractures
-
Karlsson M.K., Hasserius R., Besjakov J., Karlsson C., and Josefsson P.O. Comparison of tension-band and figure-of-eight wiring techniques for treatment of olecranon fractures. J Shoulder Elbow Surg 11 (2002) 377-382
-
(2002)
J Shoulder Elbow Surg
, vol.11
, pp. 377-382
-
-
Karlsson, M.K.1
Hasserius, R.2
Besjakov, J.3
Karlsson, C.4
Josefsson, P.O.5
-
18
-
-
0018192748
-
Fractures of the olecranon: Analysis of 37 consecutive cases
-
Kivilouto O., and Santavirta S. Fractures of the olecranon: Analysis of 37 consecutive cases. Acta Orthop Scand 49 (1978) 28-31
-
(1978)
Acta Orthop Scand
, vol.49
, pp. 28-31
-
-
Kivilouto, O.1
Santavirta, S.2
-
19
-
-
0025741050
-
Tension-band wiring of olecranon fractures with nonsliding pins. Report of 20 cases
-
Larsen E., and Jensen C.M. Tension-band wiring of olecranon fractures with nonsliding pins. Report of 20 cases. Acta Orthop Scand 62 (1991) 360-362
-
(1991)
Acta Orthop Scand
, vol.62
, pp. 360-362
-
-
Larsen, E.1
Jensen, C.M.2
-
20
-
-
0022308950
-
Complications of tension-band wiring of olecranon fractures
-
Macko D., and Szabo R.M. Complications of tension-band wiring of olecranon fractures. J Bone Joint Surg Am 67A (1985) 1396-1401
-
(1985)
J Bone Joint Surg Am
, vol.67 A
, pp. 1396-1401
-
-
Macko, D.1
Szabo, R.M.2
-
21
-
-
33847687388
-
Protrusion of hardware impairs forearm rotation after olecranon fixation
-
Matthews F., Trentz O., Jacob A.L., Kikinis R., Jupiter J.B., and Messmer P. Protrusion of hardware impairs forearm rotation after olecranon fixation. J Bone Joint Surg Am 89A (2007) 638-642
-
(2007)
J Bone Joint Surg Am
, vol.89 A
, pp. 638-642
-
-
Matthews, F.1
Trentz, O.2
Jacob, A.L.3
Kikinis, R.4
Jupiter, J.B.5
Messmer, P.6
-
22
-
-
64849086116
-
Nonunion, delayed union, malunion and avascular necrosis
-
Epps Jr. C.H. (Ed), JB Lippincott, Philadelphia
-
Mayer P.J., and Evarts C.M. Nonunion, delayed union, malunion and avascular necrosis. In: Epps Jr. C.H. (Ed). Complications in orthopaedic surgery Vol 1 (1978), JB Lippincott, Philadelphia 159-175
-
(1978)
Complications in orthopaedic surgery
, vol.1
, pp. 159-175
-
-
Mayer, P.J.1
Evarts, C.M.2
-
23
-
-
0034237449
-
K-wire position in tension band wiring of the olecranon: a comparison of two techniques
-
Mullett J.H., Shannon F., Noel J., Lawlor G., Lee T.C., and ÓRourke S.K. K-wire position in tension band wiring of the olecranon: a comparison of two techniques. Injury 31 (2000) 427-431
-
(2000)
Injury
, vol.31
, pp. 427-431
-
-
Mullett, J.H.1
Shannon, F.2
Noel, J.3
Lawlor, G.4
Lee, T.C.5
ÓRourke, S.K.6
-
25
-
-
0004254111
-
-
Springer-Verlag, New York
-
Müller M.E., Allgöwer M., Schneider R., and Willenegger H. Manual of internal fixation: Techniques recommended by the AO group (1970), Springer-Verlag, New York
-
(1970)
Manual of internal fixation: Techniques recommended by the AO group
-
-
Müller, M.E.1
Allgöwer, M.2
Schneider, R.3
Willenegger, H.4
-
26
-
-
0019948173
-
Non-sliding pins in traction absorbing wiring of fractures: a modified technique
-
Netz P., and Stromberg L. Non-sliding pins in traction absorbing wiring of fractures: a modified technique. Acta Orthop Scand 53 (1982) 355-360
-
(1982)
Acta Orthop Scand
, vol.53
, pp. 355-360
-
-
Netz, P.1
Stromberg, L.2
-
27
-
-
0035403706
-
Surgical treatment of olecranon fractures
-
Nork S.E., Jones C.B., and Henley M.B. Surgical treatment of olecranon fractures. Am J Orthop 30 (2001) 577-586
-
(2001)
Am J Orthop
, vol.30
, pp. 577-586
-
-
Nork, S.E.1
Jones, C.B.2
Henley, M.B.3
-
29
-
-
0031267131
-
Biomechanical comparison of fixation methods in transverse olecranon fractures: A cadaveric study
-
Prayson M.J., Williams J.L., Marshall M.P., Scilaris T.A., and Lingenfelter E.J. Biomechanical comparison of fixation methods in transverse olecranon fractures: A cadaveric study. J Orthop Trauma 11 (1997) 565-572
-
(1997)
J Orthop Trauma
, vol.11
, pp. 565-572
-
-
Prayson, M.J.1
Williams, J.L.2
Marshall, M.P.3
Scilaris, T.A.4
Lingenfelter, E.J.5
-
30
-
-
0018346616
-
Fracture of the olecranon: A problem of management
-
Rettig A.C., Waugh T.R., and Evansky P.M. Fracture of the olecranon: A problem of management. J Trauma 19 (1979) 23-28
-
(1979)
J Trauma
, vol.19
, pp. 23-28
-
-
Rettig, A.C.1
Waugh, T.R.2
Evansky, P.M.3
-
31
-
-
0026572229
-
Tension band wiring of olecranon fractures. A modification of the AO technique
-
Rowland S.A., and Burkhart S.S. Tension band wiring of olecranon fractures. A modification of the AO technique. Clin Orthop 277 (1992) 238-242
-
(1992)
Clin Orthop
, vol.277
, pp. 238-242
-
-
Rowland, S.A.1
Burkhart, S.S.2
-
33
-
-
0030198892
-
Contoured LCDC plating of the proximal ulna
-
Simpson N.S., Goodman L.A., and Jupiter J.B. Contoured LCDC plating of the proximal ulna. Injury 27 (1996) 411-417
-
(1996)
Injury
, vol.27
, pp. 411-417
-
-
Simpson, N.S.1
Goodman, L.A.2
Jupiter, J.B.3
-
34
-
-
26444468910
-
Proximal radio-ulnar synostosis complicating tension band wiring of the fractured olecranon
-
Velkes S., Tytiun Y., and Salai M. Proximal radio-ulnar synostosis complicating tension band wiring of the fractured olecranon. Injury 36 (2005) 1254-1256
-
(2005)
Injury
, vol.36
, pp. 1254-1256
-
-
Velkes, S.1
Tytiun, Y.2
Salai, M.3
-
35
-
-
0023472436
-
Surgical treatment of displaced olecranon fractures by tension band wiring technique
-
Wolfgang G., Burke F., Bush D., Parenti J., Perry J., LaFollette B., et al. Surgical treatment of displaced olecranon fractures by tension band wiring technique. Clin Orthop 224 (1987) 192-204
-
(1987)
Clin Orthop
, vol.224
, pp. 192-204
-
-
Wolfgang, G.1
Burke, F.2
Bush, D.3
Parenti, J.4
Perry, J.5
LaFollette, B.6
|