Volumn 93, Issue 4, 2009, Pages 518-525

Fundus autofluorescence and Fourier-domain optical coherence tomography imaging of 10 and 20 millisecond Pascal retinal photocoagulation treatment

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; AUTOFLUORESCENCE IMAGING; BURN; CLINICAL ARTICLE; DIABETIC MACULAR EDEMA; DIABETIC RETINOPATHY; FEMALE; FOLLOW UP; FOURIER DOMAIN OPTICAL COHERENCE TOMOGRAPHY; FUNDUS AUTOFLUORESCENCE; HUMAN; IMAGING; LASER COAGULATION; MALE; NEODYMIUM LASER; OPHTHALMOSCOPY; OPTICAL COHERENCE TOMOGRAPHY; PATTERN SCANNING LASER PHOTOCOAGULATION; PIGMENT EPITHELIUM; PRIORITY JOURNAL; RETINA;

EID: 64849115652     PISSN: 00071161     EISSN: 14682079     Source Type: Journal    
DOI: 10.1136/bjo.2008.148833     Document Type: Article
Times cited : (50)

References (20)
  • 1
    • 0022347471 scopus 로고
    • Photocoagulation for diabetic macular edema. Early Treatment Diabetic Retinopathy Study
    • Early Treatment Diabetic Retinopathy Study Research Group
    • Early Treatment Diabetic Retinopathy Study Research Group. Photocoagulation for diabetic macular edema. Early Treatment Diabetic Retinopathy Study report number 1. Arch Ophthalmol 1985;103:1796- 806.
    • (1985) Arch Ophthalmol , vol.103 , pp. 1796-1806
  • 2
    • 34247164981 scopus 로고    scopus 로고
    • Comparison of the modified early treatment diabetic retinopathy study and mild macular grid laser photcoagulation strategies for diabetic macular edema
    • Writing Committee for the Diabetic Retinopathy Clinical Research Network
    • Writing Committee for the Diabetic Retinopathy Clinical Research Network, Fong DS, Strauber SF, et al. Comparison of the modified early treatment diabetic retinopathy study and mild macular grid laser photcoagulation strategies for diabetic macular edema. Arch Ophthalmol 2007;125:469-80.
    • (2007) Arch Ophthalmol , vol.125 , pp. 469-480
    • Fong, D.S.1    Strauber, S.F.2
  • 3
    • 1842534208 scopus 로고    scopus 로고
    • Influence of pulse duration and pulse number in selective RPE laser treatment
    • Framme C, Schuele G, Roider J, et al. Influence of pulse duration and pulse number in selective RPE laser treatment. Lasers Surg Med 2004;34:206-15.
    • (2004) Lasers Surg Med , vol.34 , pp. 206-215
    • Framme, C.1    Schuele, G.2    Roider, J.3
  • 4
    • 11144300139 scopus 로고    scopus 로고
    • Subthreshold diode micropulse photocoagulation for the treatment of clinically significant macular oedema
    • Luttrul JK, Musch DC, Mainster MA. Subthreshold diode micropulse photocoagulation for the treatment of clinically significant macular oedema. Br J Ophthalmol 2005;89:74-80.
    • (2005) Br J Ophthalmol , vol.89 , pp. 74-80
    • Luttrul, J.K.1    Musch, D.C.2    Mainster, M.A.3
  • 5
    • 0031768344 scopus 로고    scopus 로고
    • Influence of laser photocoagulation for clinically significant macular oedema (DMO) on short-wavelength and conventional automated perimetry
    • Hudson C, Flanagan JG, Turner GS, et al. Influence of laser photocoagulation for clinically significant macular oedema (DMO) on short-wavelength and conventional automated perimetry. Diabetologica 1998;41:1283-92.
    • (1998) Diabetologica , vol.41 , pp. 1283-1292
    • Hudson, C.1    Flanagan, J.G.2    Turner, G.S.3
  • 6
    • 0032898544 scopus 로고    scopus 로고
    • Clinical applications of the micropulse diode laser
    • Moorman CM, Hamilton AM. Clinical applications of the micropulse diode laser. Eye 1999;13:145-50.
    • (1999) Eye , vol.13 , pp. 145-150
    • Moorman, C.M.1    Hamilton, A.M.2
  • 7
    • 33646462793 scopus 로고    scopus 로고
    • New instrument: Semiautomated patterned scanning laser for retinal photocoagulation
    • Blumenkranz MS, Yellachich D, Anderson DE, et al. New instrument: semiautomated patterned scanning laser for retinal photocoagulation. Retina 2006;26:370-5.
    • (2006) Retina , vol.26 , pp. 370-375
    • Blumenkranz, M.S.1    Yellachich, D.2    Anderson, D.E.3
  • 8
    • 38349073488 scopus 로고    scopus 로고
    • Effect of pulse duration on size and character of the lesion in retinal photocoagulation
    • Jain A, Blumenkranz MS, Paulus Y, et al. Effect of pulse duration on size and character of the lesion in retinal photocoagulation. Arch Ophthalmol 2008;126:78-85.
    • (2008) Arch Ophthalmol , vol.126 , pp. 78-85
    • Jain, A.1    Blumenkranz, M.S.2    Paulus, Y.3
  • 9
    • 49049106746 scopus 로고    scopus 로고
    • Initial experience with the Pascal photocoagulator: A pilot study of 75 procedures
    • Sanghvi C, McLauchlan R, Delgado C, et al. Initial experience with the Pascal photocoagulator: a pilot study of 75 procedures. Br J Ophthalmol 2008;92:1061-4.
    • (2008) Br J Ophthalmol , vol.92 , pp. 1061-1064
    • Sanghvi, C.1    McLauchlan, R.2    Delgado, C.3
  • 10
    • 0028953831 scopus 로고
    • In vivo fluorescence of the ocular fundus exhibits retinal pigment epithelium lipofuscin characteristics
    • Delori FC, Dorey CK, Staurenghi G, et al. In vivo fluorescence of the ocular fundus exhibits retinal pigment epithelium lipofuscin characteristics. Invest Ophthalmol Vis Sci 1995;36:718-29.
    • (1995) Invest Ophthalmol Vis Sci , vol.36 , pp. 718-729
    • Delori, F.C.1    Dorey, C.K.2    Staurenghi, G.3
  • 11
    • 40449094820 scopus 로고    scopus 로고
    • Fundus autofluorescence imaging:review and perspectives
    • Schmitz-Valckenberg S, Holz FG, Bird AC, et al. Fundus autofluorescence imaging:review and perspectives. Retina 2008;28:385-409.
    • (2008) Retina , vol.28 , pp. 385-409
    • Schmitz-Valckenberg, S.1    Holz, F.G.2    Bird, A.C.3
  • 12
    • 0038618462 scopus 로고    scopus 로고
    • Performance of Fourier domain vs. time domain optical coherence tomography
    • Leitgeb R, Hitzenberger CK, Fercher AF. Performance of Fourier domain vs. time domain optical coherence tomography. Opt Express 2003;11:889-94.
    • (2003) Opt Express , vol.11 , pp. 889-894
    • Leitgeb, R.1    Hitzenberger, C.K.2    Fercher, A.F.3
  • 13
    • 33646875756 scopus 로고    scopus 로고
    • Retinal assessment using optical coherence tomography
    • Costa RA, Skaf M, Melo LA Jr, et al. Retinal assessment using optical coherence tomography. Prog Retin Eye Res 2006;25:325-53.
    • (2006) Prog Retin Eye Res , vol.25 , pp. 325-353
    • Costa, R.A.1    Skaf, M.2    Melo Jr, L.A.3
  • 14
    • 0036348881 scopus 로고    scopus 로고
    • Retinal pigment epithelium translocation after choroidal neovascular membrane removal in age-related macular degeneration
    • Stanga PE, Kychenthal A, Fitzke FW, et al. Retinal pigment epithelium translocation after choroidal neovascular membrane removal in age-related macular degeneration. phthalmology 2002;109:1492-8.
    • (2002) phthalmology , vol.109 , pp. 1492-1498
    • Stanga, P.E.1    Kychenthal, A.2    Fitzke, F.W.3
  • 15
    • 0032820712 scopus 로고    scopus 로고
    • The interpretation of optical coherence images of the retina
    • Chauhan DS, Marshall J. The interpretation of optical coherence images of the retina. Invest Ophthalmol Vis Sci 1999;40:2332-42.
    • (1999) Invest Ophthalmol Vis Sci , vol.40 , pp. 2332-2342
    • Chauhan, D.S.1    Marshall, J.2
  • 16
    • 0032997035 scopus 로고    scopus 로고
    • Patterns of diabetic macular edema with optical coherence tomography
    • Otani T, Kishi S, Maruyama Y. Patterns of diabetic macular edema with optical coherence tomography. Am J Ophthalmol 1999;127:688- 93.
    • (1999) Am J Ophthalmol , vol.127 , pp. 688-693
    • Otani, T.1    Kishi, S.2    Maruyama, Y.3
  • 17
    • 0023270843 scopus 로고
    • Interferometric technique for investigation of laser thermal retinal damage
    • Krauss JM, Puliafito CA, Lin WZ, et al. Interferometric technique for investigation of laser thermal retinal damage. Invest Ophthalmol Vis Sci 1987;28:1290-7.
    • (1987) Invest Ophthalmol Vis Sci , vol.28 , pp. 1290-1297
    • Krauss, J.M.1    Puliafito, C.A.2    Lin, W.Z.3
  • 18
    • 0036785380 scopus 로고    scopus 로고
    • Autofluorescence after selective RPE laser treatment in macular diseases and clinical outcome: A pilot study
    • Framme C, Brinkmann R, Birngruber R, et al. Autofluorescence after selective RPE laser treatment in macular diseases and clinical outcome: a pilot study. Br J Ophthalmol 2002;86:1099-106.
    • (2002) Br J Ophthalmol , vol.86 , pp. 1099-1106
    • Framme, C.1    Brinkmann, R.2    Birngruber, R.3
  • 19
    • 0031014187 scopus 로고    scopus 로고
    • Argon laser retinal lesions evaluated in vivo by optical coherence tomography
    • Toth CA, Birngruber R, Boppart SA, et al. Argon laser retinal lesions evaluated in vivo by optical coherence tomography. Am J Ophthalmol 1997;123:188-98.
    • (1997) Am J Ophthalmol , vol.123 , pp. 188-198
    • Toth, C.A.1    Birngruber, R.2    Boppart, S.A.3
  • 20
    • 0026075103 scopus 로고
    • Progressive enlargement of laser scars following grid laser photocoagulation for diffuse diabetic macular oedema
    • Schatz H, Madeira D, McDonald HR, et al. Progressive enlargement of laser scars following grid laser photocoagulation for diffuse diabetic macular oedema. Arch Ophthalmol 1991;109:1549-51.
    • (1991) Arch Ophthalmol , vol.109 , pp. 1549-1551
    • Schatz, H.1    Madeira, D.2    McDonald, H.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.