메뉴 건너뛰기




Volumn 403, Issue 1-2, 2009, Pages 259-260

Discordance of cardiac troponin I assays on the point-of-care i-STAT and Architect assays from Abbott Diagnostics

Author keywords

[No Author keywords available]

Indexed keywords

TROPONIN I;

EID: 64849104140     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cca.2009.01.017     Document Type: Letter
Times cited : (18)

References (6)
  • 1
    • 2942519369 scopus 로고    scopus 로고
    • Analytical performance of the i-STAT cardiac troponin I assay
    • Apple F.S., Murakami M.M., Christtenson R.H., et al. Analytical performance of the i-STAT cardiac troponin I assay. Clin Chim Acta 345 (2004) 123-127
    • (2004) Clin Chim Acta , vol.345 , pp. 123-127
    • Apple, F.S.1    Murakami, M.M.2    Christtenson, R.H.3
  • 2
    • 64849089121 scopus 로고    scopus 로고
    • Serum and plasma 99th percentile reference limits for the Ortho Clinical Diagnostic, Abbott Architect and Beckman Coulter Access second generation cardiac troponin I assays
    • Murakami M.M., Farris D.P., Ler R., and Apple F.S. Serum and plasma 99th percentile reference limits for the Ortho Clinical Diagnostic, Abbott Architect and Beckman Coulter Access second generation cardiac troponin I assays. Clin Chem 52 (2006) A136
    • (2006) Clin Chem , vol.52
    • Murakami, M.M.1    Farris, D.P.2    Ler, R.3    Apple, F.S.4
  • 3
    • 36249003906 scopus 로고    scopus 로고
    • Universal definition of myocardial infarction
    • Thygesen K., Alpert J.S., and White H.D. Universal definition of myocardial infarction. J Am Coll Cardiol 50 (2007) 2173-2195
    • (2007) J Am Coll Cardiol , vol.50 , pp. 2173-2195
    • Thygesen, K.1    Alpert, J.S.2    White, H.D.3
  • 4
    • 27444431706 scopus 로고    scopus 로고
    • Validation of the 99th percentile cutoff independent of assay imprecision (CV) for cardiac troponin monitoring for ruling out myocardial infarction
    • Apple F.S., Parvin C.A., Buechler K.F., Christenson R.H., Wu A.H.B., and Jaffe A.S. Validation of the 99th percentile cutoff independent of assay imprecision (CV) for cardiac troponin monitoring for ruling out myocardial infarction. Clin Chem 51 (2005) 2198-2200
    • (2005) Clin Chem , vol.51 , pp. 2198-2200
    • Apple, F.S.1    Parvin, C.A.2    Buechler, K.F.3    Christenson, R.H.4    Wu, A.H.B.5    Jaffe, A.S.6
  • 5
    • 34147193756 scopus 로고    scopus 로고
    • National academy of clinical biochemistry and IFCC committee for standardization of markers of cardiac damage laboratory medicine practice guidelines: analytical issues for biochemical markers of acute coronary syndromes
    • Apple F.S., Jesse R.L., Newby L.K., Wu A.H.B., and Christenson R.H. National academy of clinical biochemistry and IFCC committee for standardization of markers of cardiac damage laboratory medicine practice guidelines: analytical issues for biochemical markers of acute coronary syndromes. Clin Chem 53 (2007) 547-551
    • (2007) Clin Chem , vol.53 , pp. 547-551
    • Apple, F.S.1    Jesse, R.L.2    Newby, L.K.3    Wu, A.H.B.4    Christenson, R.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.