메뉴 건너뛰기




Volumn 40, Issue 2, 2009, Pages 127-134

Advantages of using a ray-traced, three-dimensional rendering system for spectral domain cirrus HD-OCT to visualize subtle structures of the vitreoretinal interface

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CONTROLLED STUDY; EPIRETINAL MEMBRANE; EYE FUNDUS; HUMAN; OPTICAL COHERENCE TOMOGRAPHY; PIGMENT EPITHELIUM; PRIORITY JOURNAL; RETINA MACULA HOLE; RETINA SURGERY; VITRECTOMY; VITREOUS BODY DETACHMENT; ALGORITHM; FLUORESCENCE ANGIOGRAPHY; FOURIER ANALYSIS; PATHOLOGY; RETINA; RETINA TEAR; THREE DIMENSIONAL IMAGING; VITREOUS BODY;

EID: 64849095557     PISSN: 15428877     EISSN: None     Source Type: Journal    
DOI: 10.3928/15428877-20090301-08     Document Type: Article
Times cited : (18)

References (18)
  • 1
    • 2942703878 scopus 로고    scopus 로고
    • Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    • Choma MA, Sarunic MV, Yang C, Izatt JA. Sensitivity advantage of swept source and Fourier domain optical coherence tomography. Opt Express. 2003;11:2183.
    • (2003) Opt Express , vol.11 , pp. 2183
    • Choma, M.A.1    Sarunic, M.V.2    Yang, C.3    Izatt, J.A.4
  • 2
    • 0242301675 scopus 로고    scopus 로고
    • Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
    • De Boer JF, Cense B, Park BH, Pierce MC, Tearney GJ, Bouma BE. Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. Opt Lett. 2003;28:2067-2069.
    • (2003) Opt Lett , vol.28 , pp. 2067-2069
    • De Boer, J.F.1    Cense, B.2    Park, B.H.3    Pierce, M.C.4    Tearney, G.J.5    Bouma, B.E.6
  • 5
    • 1642602745 scopus 로고    scopus 로고
    • Ultrahigh resolution optical coherence tomography
    • Drexler W. Ultrahigh resolution optical coherence tomography. J Biomed Opt. 2004;9:47-74.
    • (2004) J Biomed Opt , vol.9 , pp. 47-74
    • Drexler, W.1
  • 6
    • 0001936881 scopus 로고
    • Measurement of intraocular distances by backscattering spectral interferometry
    • Fercher AF, Hitzenberger CK, Kamp G, El-Zaiat SY. Measurement of intraocular distances by backscattering spectral interferometry. Opt Commun. 1995;117:43-48.
    • (1995) Opt Commun , vol.117 , pp. 43-48
    • Fercher, A.F.1    Hitzenberger, C.K.2    Kamp, G.3    El-Zaiat, S.Y.4
  • 10
    • 27644479517 scopus 로고    scopus 로고
    • Comparison of ultrahigh- And standard-resolution optical coherence tomography for imaging macular pathology
    • Ko TH, Fujimoto JG, Schuman JS, et al. Comparison of ultrahigh- and standard-resolution optical coherence tomography for imaging macular pathology. Ophthalmology. 2005;112:1922.
    • (2005) Ophthalmology , vol.112 , pp. 1922
    • Ko, T.H.1    Fujimoto, J.G.2    Schuman, J.S.3
  • 11
    • 0038618462 scopus 로고    scopus 로고
    • Performance of Fourier domain vs. time domain optical coherence tomography
    • Leitgeb RA, Hitzenberger CK, Fercher AF. Performance of Fourier domain vs. time domain optical coherence tomography. Opt Express. 2003;11:889-894.
    • (2003) Opt Express , vol.11 , pp. 889-894
    • Leitgeb, R.A.1    Hitzenberger, C.K.2    Fercher, A.F.3
  • 13
    • 25844456000 scopus 로고    scopus 로고
    • Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography
    • DOI 10.1016/j.ophtha.2005.05.023, PII S016164200500816X
    • Wojtkowski M, Srinivasan V, Fujimoto JG, Ko T, Schuman JS, Kowalczyk A, Duker JS. Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography. Ophthalmology. 2005;112:1734-1746. (Pubitemid 41400010)
    • (2005) Ophthalmology , vol.112 , Issue.10 , pp. 1734-1746
    • Wojtkowski, M.1    Srinivasan, V.2    Fujimoto, J.G.3    Ko, T.4    Schuman, J.S.5    Kowalczyk, A.6    Duker, J.S.7
  • 14
    • 39149134265 scopus 로고    scopus 로고
    • Three-dimensional evaluation of vitreomacular traction and epiretinal membrane using spectral-domain optical coherence tomography
    • Jan 10. Epub ahead of print
    • Koizumi H, Spaide RF, Fisher YL, et al. Three-dimensional evaluation of vitreomacular traction and epiretinal membrane using spectral-domain optical coherence tomography. Am J Ophthalmol. 2008 Jan 10. Epub ahead of print.
    • (2008) Am J Ophthalmol
    • Koizumi, H.1    Spaide, R.F.2    Fisher, Y.L.3
  • 17
    • 38949189334 scopus 로고    scopus 로고
    • Automatic segmentation in three-dimensional analysis of fibrovascular pigment epithelial detachment using high-definition optical coherence tomography
    • Ahlers C, Simader C, Geitzenauer W, et al. Automatic segmentation in three-dimensional analysis of fibrovascular pigment epithelial detachment using high-definition optical coherence tomography. Br J Ophthalmol. 2008;92:197-203.
    • (2008) Br J Ophthalmol , vol.92 , pp. 197-203
    • Ahlers, C.1    Simader, C.2    Geitzenauer, W.3
  • 18
    • 35349014156 scopus 로고    scopus 로고
    • Posterior Vitreomacular Adhesion: A Potential Risk Factor for Exudative Age-related Macular Degeneration?
    • DOI 10.1016/j.ajo.2007.07.024, PII S0002939407006642
    • Krebs I, Brannath W, Glittenberg C, et al. Posterior vitreomacular adhesion: a potential risk factor for exudative age-related macular degeneration? Am J Ophthalmol. 2007;144:741-746. (Pubitemid 47614954)
    • (2007) American Journal of Ophthalmology , vol.144 , Issue.5
    • Krebs, I.1    Brannath, W.2    Glittenberg, C.3    Zeiler, F.4    Sebag, J.5    Binder, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.