메뉴 건너뛰기




Volumn 53, Issue 5, 2009, Pages 689-690

When to recalibrate the PiCCO™? from a physiological point of view, the answer is simple

Author keywords

[No Author keywords available]

Indexed keywords

AREA UNDER THE CURVE; ARTERIAL PULSE CONTOUR ANALYSIS; ARTERY RESISTANCE; BLOOD VESSEL COMPLIANCE; CALCULATION; CALIBRATION; HEART OUTPUT MEASUREMENT; HEART STROKE VOLUME; HEMODYNAMIC MONITORING; HUMAN; INTENSIVE CARE UNIT; LETTER; MATHEMATICAL MODEL; PARAMETER; PATIENT MONITORING; PRIORITY JOURNAL; PULSE PRESSURE; PULSE WAVE; TECHNIQUE; TRANSPULMONARY THERMODILUTION TECHNIQUE; VASCULAR RESISTANCE; BLOOD PRESSURE; HEART OUTPUT; HEMODYNAMICS; INSTRUMENTATION; INTENSIVE CARE; LUNG CIRCULATION; MONITORING; PHYSIOLOGY; STATISTICAL MODEL; THERMODILUTION;

EID: 64749114272     PISSN: 00015172     EISSN: 13996576     Source Type: Journal    
DOI: 10.1111/j.1399-6576.2009.01919.x     Document Type: Letter
Times cited : (16)

References (12)
  • 2
    • 49949115276 scopus 로고    scopus 로고
    • Volume assessment in patients with necrotizing pancreatitis: A comparison of intrathoracic blood volume index, central venous pressure, and hematocrit, and their correlation to cardiac index and extravascular lung water index
    • Huber W, Umgelter A, Reindl W, Franzen M, Schmidt C, von Delius S, Geisler F, Eckel F, Fritsch R, Siveke J, Henschel B, Schmid RM. Volume assessment in patients with necrotizing pancreatitis: a comparison of intrathoracic blood volume index, central venous pressure, and hematocrit, and their correlation to cardiac index and extravascular lung water index. Crit Care Med 2008 36 : 2348 54.
    • (2008) Crit Care Med , vol.36 , pp. 2348-54
    • Huber, W.1    Umgelter, A.2    Reindl, W.3    Franzen, M.4    Schmidt, C.5    Von Delius, S.6    Geisler, F.7    Eckel, F.8    Fritsch, R.9    Siveke, J.10    Henschel, B.11    Schmid, R.M.12
  • 3
    • 0017420177 scopus 로고
    • Pulse contour cardiac output as a clinically valuable tool for intensive patient monitoring. A critique of a recent paper
    • Wesseling KH. Pulse contour cardiac output as a clinically valuable tool for intensive patient monitoring. A critique of a recent paper. Basic Res Cardiol 1977 72 : 82 8.
    • (1977) Basic Res Cardiol , vol.72 , pp. 82-8
    • Wesseling, K.H.1
  • 4
    • 0027195184 scopus 로고
    • Computation of aortic flow from pressure in humans using a nonlinear, three-element model
    • Wesseling KH, Jansen JR, Settels JJ, Schreuder JJ. Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol 1993 74 : 2566 73.
    • (1993) J Appl Physiol , vol.74 , pp. 2566-73
    • Wesseling, K.H.1    Jansen, J.R.2    Settels, J.J.3    Schreuder, J.J.4
  • 5
    • 0000940103 scopus 로고
    • Ueber die messung des schlagvolumens des herzens auf unblutigem weg
    • Broemser Ph. Ueber die messung des schlagvolumens des herzens auf unblutigem weg. Zeitung Für Biologie 1930 90 : 467 507.
    • (1930) Zeitung für Biologie , vol.90 , pp. 467-507
    • Broemser, P.1
  • 6
    • 0042482769 scopus 로고    scopus 로고
    • Continuous cardiac output measurement: Pulse contour analysis vs thermodilution technique in cardiac surgical patients
    • Rodig G, Prasser C, Keyl C, Liebold A, Hobbhahn J. Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients. Br J Anaesth 1999 82 : 525 30.
    • (1999) Br J Anaesth , vol.82 , pp. 525-30
    • Rodig, G.1    Prasser, C.2    Keyl, C.3    Liebold, A.4    Hobbhahn, J.5
  • 7
    • 79959839441 scopus 로고
    • Translated into english by Clifford WK. on the hypotheses which lie at the bases of geometry
    • 36-37
    • Riemann B. Translated into english by Clifford WK. On the hypotheses which lie at the bases of geometry. Nature 1873 8 : 14 7, 36-37.
    • (1873) Nature , vol.8 , pp. 14-7
    • Riemann, B.1
  • 8
    • 0346732923 scopus 로고    scopus 로고
    • The respiratory change in preejection period: A new method to predict fluid responsiveness
    • Bendjelid K, Suter PM, Romand JA. The respiratory change in preejection period: a new method to predict fluid responsiveness. J Appl Physiol 2004 96 : 337 42.
    • (2004) J Appl Physiol , vol.96 , pp. 337-42
    • Bendjelid, K.1    Suter, P.M.2    Romand, J.A.3
  • 9
    • 0035080242 scopus 로고    scopus 로고
    • Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery
    • Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 2001 92 : 984 9.
    • (2001) Anesth Analg , vol.92 , pp. 984-9
    • Berkenstadt, H.1    Margalit, N.2    Hadani, M.3    Friedman, Z.4    Segal, E.5    Villa, Y.6    Perel, A.7
  • 10
    • 0036219991 scopus 로고    scopus 로고
    • Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery
    • Reuter DA, Felbinger TW, Schmidt C, Kilger E, Goedje O, Lamm P, Goetz AE. Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 2002 28 : 392 8.
    • (2002) Intensive Care Med , vol.28 , pp. 392-8
    • Reuter, D.A.1    Felbinger, T.W.2    Schmidt, C.3    Kilger, E.4    Goedje, O.5    Lamm, P.6    Goetz, A.E.7
  • 11


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.