메뉴 건너뛰기




Volumn 197, Issue 5, 2009, Pages 595-598

Prophylactic mesh to prevent incisional hernia: A note of caution

Author keywords

Bariatric surgery; Complications; Hernia; Mesh; Prophylactic

Indexed keywords

ADULT; ARTICLE; BODY MASS; CLINICAL ARTICLE; DIABETES MELLITUS; EXCISION; FEMALE; FOLLOW UP; HUMAN; INCIDENCE; INCISIONAL HERNIA; INFECTION; MALE; MESH SLING; MORBIDITY; NAUSEA AND VOMITING; OBESITY; OUTCOME ASSESSMENT; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RECURRENT DISEASE; SEROMA; STOMACH BYPASS; SURGEON;

EID: 64749102720     PISSN: 00029610     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.amjsurg.2009.01.002     Document Type: Article
Times cited : (41)

References (14)
  • 1
    • 26844444225 scopus 로고    scopus 로고
    • Hospitalization before and after gastric bypass surgery
    • Zingmond D.S., McGory M.L., and Ko C.Y. Hospitalization before and after gastric bypass surgery. JAMA 294 (2005) 1918-1924
    • (2005) JAMA , vol.294 , pp. 1918-1924
    • Zingmond, D.S.1    McGory, M.L.2    Ko, C.Y.3
  • 2
    • 0030048603 scopus 로고    scopus 로고
    • Greater risk of incisional hernia with morbidly obese than steroid-dependent patients and low recurrence with prefascial polypropylene mesh
    • Sugerman H.J., Kellum Jr. J.M., Reines H.D., et al. Greater risk of incisional hernia with morbidly obese than steroid-dependent patients and low recurrence with prefascial polypropylene mesh. Am J Surg 171 (1996) 80-84
    • (1996) Am J Surg , vol.171 , pp. 80-84
    • Sugerman, H.J.1    Kellum Jr., J.M.2    Reines, H.D.3
  • 3
    • 31844436246 scopus 로고    scopus 로고
    • Three-year follow-up of a prospective randomized trial comparing laparoscopic versus open gastric bypass
    • Puzziferri N., Austrheim-Smith I.T., Wolfe B.M., et al. Three-year follow-up of a prospective randomized trial comparing laparoscopic versus open gastric bypass. Ann Surg 243 (2006) 181-188
    • (2006) Ann Surg , vol.243 , pp. 181-188
    • Puzziferri, N.1    Austrheim-Smith, I.T.2    Wolfe, B.M.3
  • 4
    • 0034849468 scopus 로고    scopus 로고
    • Laparoscopic versus open gastric bypass: a randomized study of outcomes, quality of life, and costs
    • Nguyen N.T., Goldman C., Rosenquist C.J., et al. Laparoscopic versus open gastric bypass: a randomized study of outcomes, quality of life, and costs. Ann Surg 234 (2001) 279-289
    • (2001) Ann Surg , vol.234 , pp. 279-289
    • Nguyen, N.T.1    Goldman, C.2    Rosenquist, C.J.3
  • 5
    • 1942505645 scopus 로고    scopus 로고
    • Incidence of incisional hernia following vertical banded gastroplasty
    • Arribas D., Elia M., Artigas C., et al. Incidence of incisional hernia following vertical banded gastroplasty. Hernia May 8 (2004) 135-137
    • (2004) Hernia May , vol.8 , pp. 135-137
    • Arribas, D.1    Elia, M.2    Artigas, C.3
  • 6
    • 0041917329 scopus 로고    scopus 로고
    • Complications after laparoscopic gastric bypass: a review of 3464 cases
    • Podnos Y.D., Jimenez J.C., Wilson S.E., et al. Complications after laparoscopic gastric bypass: a review of 3464 cases. Arch Surg 138 (2003) 957-961
    • (2003) Arch Surg , vol.138 , pp. 957-961
    • Podnos, Y.D.1    Jimenez, J.C.2    Wilson, S.E.3
  • 7
    • 45749097412 scopus 로고    scopus 로고
    • Risk of complications from enterotomy or unplanned bowel resection during elective hernia repair
    • Gray S.H., Vick C.C., Graham L.A., et al. Risk of complications from enterotomy or unplanned bowel resection during elective hernia repair. Arch Surg 143 (2008) 582-586
    • (2008) Arch Surg , vol.143 , pp. 582-586
    • Gray, S.H.1    Vick, C.C.2    Graham, L.A.3
  • 8
    • 0036594405 scopus 로고    scopus 로고
    • The safety and efficacy of prosthetic hernia repair in clean-contaminated and contaminated wounds
    • Kelly M.E., and Behrman S.W. The safety and efficacy of prosthetic hernia repair in clean-contaminated and contaminated wounds. Am Surg 68 (2002) 524-528
    • (2002) Am Surg , vol.68 , pp. 524-528
    • Kelly, M.E.1    Behrman, S.W.2
  • 9
    • 0042529031 scopus 로고    scopus 로고
    • Safety and outcome of use of nonabsorbable mesh for repair of fascial defects in the presence of open bowel
    • Geisler D.J., Reilly J.C., Vaughan S.G., et al. Safety and outcome of use of nonabsorbable mesh for repair of fascial defects in the presence of open bowel. Dis Colon Rectum 46 (2003) 1118-1123
    • (2003) Dis Colon Rectum , vol.46 , pp. 1118-1123
    • Geisler, D.J.1    Reilly, J.C.2    Vaughan, S.G.3
  • 10
    • 4444362777 scopus 로고    scopus 로고
    • Prosthetic repair, intestinal resection, and potentially contaminated areas: safe and feasible?
    • Campanelli G., Nicolosi F.M., Pettinari D., et al. Prosthetic repair, intestinal resection, and potentially contaminated areas: safe and feasible?. Hernia 8 (2004) 190-192
    • (2004) Hernia , vol.8 , pp. 190-192
    • Campanelli, G.1    Nicolosi, F.M.2    Pettinari, D.3
  • 11
    • 33750957674 scopus 로고    scopus 로고
    • Randomized clinical trial of postoperative hernia prophylaxis in open bariatric surgery
    • Strzelczyk J.M., Szymanski D., Nowicki M.E., et al. Randomized clinical trial of postoperative hernia prophylaxis in open bariatric surgery. Br J Surg 93 (2006) 1347-1350
    • (2006) Br J Surg , vol.93 , pp. 1347-1350
    • Strzelczyk, J.M.1    Szymanski, D.2    Nowicki, M.E.3
  • 12
    • 0031859834 scopus 로고    scopus 로고
    • Factors affecting wound complications in repair of ventral hernias
    • White T.J., Santos M.C., and Thompson J.S. Factors affecting wound complications in repair of ventral hernias. Am Surg 64 (1998) 276-280
    • (1998) Am Surg , vol.64 , pp. 276-280
    • White, T.J.1    Santos, M.C.2    Thompson, J.S.3
  • 13
    • 13644259491 scopus 로고    scopus 로고
    • Mesh-related infections after hernia repair surgery
    • Falagas M.E., and Kasiakou S.K. Mesh-related infections after hernia repair surgery. Clin Microbiol Infect 11 (2005) 3-8
    • (2005) Clin Microbiol Infect , vol.11 , pp. 3-8
    • Falagas, M.E.1    Kasiakou, S.K.2
  • 14
    • 0033819114 scopus 로고    scopus 로고
    • Elective colonic operation and prosthetic repair of incisional hernia: does contamination contraindicate abdominal wall prosthesis use?
    • Birolini C., Utiyama E.M., Rodrigues Jr. A.J., et al. Elective colonic operation and prosthetic repair of incisional hernia: does contamination contraindicate abdominal wall prosthesis use?. J Am Coll Surg 191 (2000) 366-372
    • (2000) J Am Coll Surg , vol.191 , pp. 366-372
    • Birolini, C.1    Utiyama, E.M.2    Rodrigues Jr., A.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.