-
1
-
-
0014311521
-
A technique for complete replacement of the ascending aorta
-
Bentall H., and De Bono A. A technique for complete replacement of the ascending aorta. Thorax 23 (1968) 338-339
-
(1968)
Thorax
, vol.23
, pp. 338-339
-
-
Bentall, H.1
De Bono, A.2
-
2
-
-
0022623687
-
Long-term results with total replacement of the ascending aorta and reimplantation of the coronary arteries
-
Cabrol C., Pavie A., Mesnildrey P., Gandjbakhch I.G., Laughlin L., Bors B., et al. Long-term results with total replacement of the ascending aorta and reimplantation of the coronary arteries. J Thorac Cardiovasc Surg 91 (1986) 17-25
-
(1986)
J Thorac Cardiovasc Surg
, vol.91
, pp. 17-25
-
-
Cabrol, C.1
Pavie, A.2
Mesnildrey, P.3
Gandjbakhch, I.G.4
Laughlin, L.5
Bors, B.6
-
3
-
-
3543122768
-
Surgery of the thoracic aorta
-
Westaby S. (Ed), Isis Medical Media, Oxford
-
Westaby S., and Cecil B. Surgery of the thoracic aorta. In: Westaby S. (Ed). Landmarks in cardiac surgery (1997), Isis Medical Media, Oxford 223
-
(1997)
Landmarks in cardiac surgery
, pp. 223
-
-
Westaby, S.1
Cecil, B.2
-
4
-
-
0019438760
-
Resection of ascending aortic aneurysm and replacement of aortic valve
-
Kouchoukos N.T., and Karp R.B. Resection of ascending aortic aneurysm and replacement of aortic valve. J Thorac Cardiovasc Surg 81 (1981) 142-143
-
(1981)
J Thorac Cardiovasc Surg
, vol.81
, pp. 142-143
-
-
Kouchoukos, N.T.1
Karp, R.B.2
-
5
-
-
0037603129
-
Operative risk factors of type A aortic dissection: analysis of 252 consecutive patients
-
Tan M.E., Dossche K.M., Morshuis W.J., Knaepen P.J., Defauw J.J., van Swieten H.A., et al. Operative risk factors of type A aortic dissection: analysis of 252 consecutive patients. Cardiovasc Surg 11 (2003) 277-285
-
(2003)
Cardiovasc Surg
, vol.11
, pp. 277-285
-
-
Tan, M.E.1
Dossche, K.M.2
Morshuis, W.J.3
Knaepen, P.J.4
Defauw, J.J.5
van Swieten, H.A.6
-
6
-
-
0034223051
-
A new aortic Dacron conduit for surgical treatment of aortic root pathology
-
De Paulis R., De Matteis G.M., Nardi P., Scaffa R., Colella D.F., and Chiarello L. A new aortic Dacron conduit for surgical treatment of aortic root pathology. Ital Heart J 1 (2000) 457-463
-
(2000)
Ital Heart J
, vol.1
, pp. 457-463
-
-
De Paulis, R.1
De Matteis, G.M.2
Nardi, P.3
Scaffa, R.4
Colella, D.F.5
Chiarello, L.6
-
7
-
-
33747364696
-
Early results of valve-sparing reimplantation procedure using the Valsalva conduit: a multicenter study
-
Pacini D., Settepani F., De Paulis R., Loforte A., Nardella S., Ornaghi D., et al. Early results of valve-sparing reimplantation procedure using the Valsalva conduit: a multicenter study. Ann Thorac Surg 82 (2006) 865-872
-
(2006)
Ann Thorac Surg
, vol.82
, pp. 865-872
-
-
Pacini, D.1
Settepani, F.2
De Paulis, R.3
Loforte, A.4
Nardella, S.5
Ornaghi, D.6
-
8
-
-
16644362264
-
Bentall procedures with a novel valved conduit incorporating "sinuses of Valsalva."
-
De Paulis R., Bassano C., Scaffa R., Nardi P., Bertoldo F., and Chiariello L. Bentall procedures with a novel valved conduit incorporating "sinuses of Valsalva.". Surg Technol Int 12 (2004) 195-200
-
(2004)
Surg Technol Int
, vol.12
, pp. 195-200
-
-
De Paulis, R.1
Bassano, C.2
Scaffa, R.3
Nardi, P.4
Bertoldo, F.5
Chiariello, L.6
-
9
-
-
0032113799
-
Stress variations in the human aortic root and valve: the role of anatomic symmetry
-
Grande K.J., Cochran R.P., Reinhall P.G., and Kunzelman K.S. Stress variations in the human aortic root and valve: the role of anatomic symmetry. Ann Biomed Eng 26 (1998) 534-545
-
(1998)
Ann Biomed Eng
, vol.26
, pp. 534-545
-
-
Grande, K.J.1
Cochran, R.P.2
Reinhall, P.G.3
Kunzelman, K.S.4
-
10
-
-
34250347811
-
The Geoform disease-specific annuloplasty system: a finite element study
-
Votta E., Maisano F., Bolling S.F., Alfieri O., Montevecchi F.M., and Redaelli A. The Geoform disease-specific annuloplasty system: a finite element study. Ann Thorac Surg 84 (2007) 92-101
-
(2007)
Ann Thorac Surg
, vol.84
, pp. 92-101
-
-
Votta, E.1
Maisano, F.2
Bolling, S.F.3
Alfieri, O.4
Montevecchi, F.M.5
Redaelli, A.6
-
11
-
-
0034040871
-
Re-creation of sinuses is important for sparing the aortic valve: a finite element study
-
Grande-Allen K.J., Cochran R.P., Reinhall P.G., and Kunzelman K.S. Re-creation of sinuses is important for sparing the aortic valve: a finite element study. J Thorac Cardiovasc Surg 119 4 Pt 1 (2000) 753-763
-
(2000)
J Thorac Cardiovasc Surg
, vol.119
, Issue.4 PART 1
, pp. 753-763
-
-
Grande-Allen, K.J.1
Cochran, R.P.2
Reinhall, P.G.3
Kunzelman, K.S.4
-
13
-
-
0002641401
-
Vascular Mechanics
-
Shepherd J.T., and Abound F. (Eds), American Physiological Society, Washington, DC
-
Dobrin P.B. Vascular Mechanics. In: Shepherd J.T., and Abound F. (Eds). Handbook of physiology Vol 3 (1983), American Physiological Society, Washington, DC 65-102
-
(1983)
Handbook of physiology
, vol.3
, pp. 65-102
-
-
Dobrin, P.B.1
-
14
-
-
0022863138
-
Non invasive assessment of aortic mechanical properties
-
Klamath S., Stupors P., and Silver H.E. Non invasive assessment of aortic mechanical properties. Ann Biomed Eng 14 (1986) 512-524
-
(1986)
Ann Biomed Eng
, vol.14
, pp. 512-524
-
-
Klamath, S.1
Stupors, P.2
Silver, H.E.3
-
15
-
-
0026575408
-
Micromechanics of the fibrosa and the ventricularis in aortic valve leaflets
-
Vesely I., and Broughner D. Micromechanics of the fibrosa and the ventricularis in aortic valve leaflets. J Biomech (1992) 101-113
-
(1992)
J Biomech
, pp. 101-113
-
-
Vesely, I.1
Broughner, D.2
-
16
-
-
0002676724
-
Control of physical characteristics (elasticity and compliance) of vascular grafts
-
Stanley J.C. (Ed), Grune & Stratton, New York
-
Abbott W.M., and Cambria R.P. Control of physical characteristics (elasticity and compliance) of vascular grafts. In: Stanley J.C. (Ed). Biologic and synthetic vascular prostheses (1982), Grune & Stratton, New York 59-78
-
(1982)
Biologic and synthetic vascular prostheses
, pp. 59-78
-
-
Abbott, W.M.1
Cambria, R.P.2
-
17
-
-
0004828847
-
Comparison and durability of tensile strength of Teflon and Dacron grafts
-
Dardik H. (Ed), Symposia Specialists Inc, Chicago
-
Edwards W.S., Snyder R.W., Botzko K., and Larkin J. Comparison and durability of tensile strength of Teflon and Dacron grafts. In: Dardik H. (Ed). Graft materials in vascular surgery (1978), Symposia Specialists Inc, Chicago 59-78
-
(1978)
Graft materials in vascular surgery
, pp. 59-78
-
-
Edwards, W.S.1
Snyder, R.W.2
Botzko, K.3
Larkin, J.4
-
19
-
-
2442621618
-
A finite element model of blunt traumatic aortic rupture
-
Richens D., Field M., Hashim S., Neale M., and Oakley C. A finite element model of blunt traumatic aortic rupture. Eur J Cardiothorac Surg 25 (2004) 1039-1047
-
(2004)
Eur J Cardiothorac Surg
, vol.25
, pp. 1039-1047
-
-
Richens, D.1
Field, M.2
Hashim, S.3
Neale, M.4
Oakley, C.5
-
20
-
-
0027161065
-
Technical modification for anastomosis of low-lying coronary ostia in Bentall procedure
-
Neveux J.Y., Dervanian P., Folliguet T.A., Macé L., and Guluta V. Technical modification for anastomosis of low-lying coronary ostia in Bentall procedure. Ann Thorac Surg 56 (1993) 383-384
-
(1993)
Ann Thorac Surg
, vol.56
, pp. 383-384
-
-
Neveux, J.Y.1
Dervanian, P.2
Folliguet, T.A.3
Macé, L.4
Guluta, V.5
-
21
-
-
0029976052
-
"Legs" technique for management of widely separated coronary arteries during ascending aortic repair
-
Mills N.L., Morgenstern D.A., Gaudiani V.A., and Ordoyne F. "Legs" technique for management of widely separated coronary arteries during ascending aortic repair. Ann Thorac Surg 61 (1996) 869-874
-
(1996)
Ann Thorac Surg
, vol.61
, pp. 869-874
-
-
Mills, N.L.1
Morgenstern, D.A.2
Gaudiani, V.A.3
Ordoyne, F.4
-
22
-
-
0032950408
-
Coronary reimplantation in aortic root replacement: a method to avoid tension
-
Westaby S., Katsumata T., and Vaccari G. Coronary reimplantation in aortic root replacement: a method to avoid tension. Ann Thorac Surg 67 (1999) 1176-1177
-
(1999)
Ann Thorac Surg
, vol.67
, pp. 1176-1177
-
-
Westaby, S.1
Katsumata, T.2
Vaccari, G.3
-
23
-
-
0026785634
-
Composite valve graft replacement of the proximal aorta: comparison of techniques in 348 patients
-
Svensson L.G., Crawford E.S., Hess K.R., Coselli J.S., and Safi H.J. Composite valve graft replacement of the proximal aorta: comparison of techniques in 348 patients. Ann Thorac Surg 54 (1992) 427-437
-
(1992)
Ann Thorac Surg
, vol.54
, pp. 427-437
-
-
Svensson, L.G.1
Crawford, E.S.2
Hess, K.R.3
Coselli, J.S.4
Safi, H.J.5
-
24
-
-
0035166384
-
Influence of technique of coronary artery implantation on long-term results in composite aortic root replacement
-
Panos A., Amahzoune B., Robin J., Champsaur G., and Ninet J. Influence of technique of coronary artery implantation on long-term results in composite aortic root replacement. Ann Thorac Surg 72 (2001) 1497-1501
-
(2001)
Ann Thorac Surg
, vol.72
, pp. 1497-1501
-
-
Panos, A.1
Amahzoune, B.2
Robin, J.3
Champsaur, G.4
Ninet, J.5
|