메뉴 건너뛰기




Volumn 54, Issue 8, 2009, Pages 2315-2322

The validation of tomotherapy dose calculations in low-density lung media

Author keywords

[No Author keywords available]

Indexed keywords

ACCEPTABLE LIMITS; CALCULATION ACCURACIES; DOSE CALCULATIONS; DOSE DISTRIBUTIONS; ESOPHAGEAL CANCERS; FILM ANALYSIS; GAMMA ANALYSIS; GAMMA TESTS; HETEROGENEOUS MEDIAS; RADIOCHROMIC FILM DOSIMETRIES; REALISTIC CONDITIONS; TOMOTHERAPY; TREATMENT PLANNING SYSTEMS; TREATMENT PLANS;

EID: 64549121050     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/8/004     Document Type: Article
Times cited : (7)

References (14)
  • 1
    • 85024942429 scopus 로고    scopus 로고
    • Verification of tangential breast treatment dose calculations in a commercial 3D treatment planning system
    • Baird C T, Starkschall G, Liu H H, Buchholz T A and Hogstrom K R 2001 Verification of tangential breast treatment dose calculations in a commercial 3D treatment planning system J. Appl. Clin. Med. Phys. 2 73-84
    • (2001) J. Appl. Clin. Med. Phys. , vol.2 , Issue.2 , pp. 73-84
    • Baird, C.T.1    Starkschall, G.2    Liu, H.H.3    Buchholz, T.A.4    Hogstrom, K.R.5
  • 2
    • 0345733892 scopus 로고    scopus 로고
    • Clinical helical tomotherapy commissioning dosimetry
    • Balog J, Olivera G H and Kapatoes J 2003 Clinical helical tomotherapy commissioning dosimetry Med. Phys. 30 3097-106
    • (2003) Med. Phys. , vol.30 , Issue.12 , pp. 3097-3106
    • Balog, J.1    Olivera, G.H.2    Kapatoes, J.3
  • 3
    • 34447325660 scopus 로고    scopus 로고
    • Design, development, and implementation of the radiological physics center's pelvis and thorax anthropomorphic quality assurance phantoms
    • Followill D S, Evans D R, Cherry C, Molineu A, Fisher G, Hanson W F and Ibbott G S 2007 Design, development, and implementation of the radiological physics center's pelvis and thorax anthropomorphic quality assurance phantoms Med. Phys. 34 2070-6
    • (2007) Med. Phys. , vol.34 , Issue.6 , pp. 2070-2076
    • Followill, D.S.1    Evans, D.R.2    Cherry, C.3    Molineu, A.4    Fisher, G.5    Hanson, W.F.6    Ibbott, G.S.7
  • 4
    • 0030699172 scopus 로고    scopus 로고
    • Correcting kernel tilting and hardening in convolution/superposition dose calculations for clinical divergent and polychromatic photon beams
    • Liu H H, Mackie T R and McCullough E C 1997 Correcting kernel tilting and hardening in convolution/superposition dose calculations for clinical divergent and polychromatic photon beams Med. Phys. 24 1729-41
    • (1997) Med. Phys. , vol.24 , Issue.11 , pp. 1729-1741
    • Liu, H.H.1    MacKie, T.R.2    McCullough, E.C.3
  • 5
    • 0141520680 scopus 로고    scopus 로고
    • Evaluation of the gamma dose distribution comparison method
    • Low D A and Dempsey J F 2003 Evaluation of the gamma dose distribution comparison method Med. Phys. 30 2455-64
    • (2003) Med. Phys. , vol.30 , Issue.9 , pp. 2455-2464
    • Low, D.A.1    Dempsey, J.F.2
  • 6
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • Low D A, Harms W B, Mutic S and Purdy J A 1998 A technique for the quantitative evaluation of dose distributions Med. Phys. 25 656-61
    • (1998) Med. Phys. , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 7
    • 14644415951 scopus 로고    scopus 로고
    • Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels
    • Lu W, Olivera G H, Chen M L, Reckwerdt P J and Mackie T R 2005 Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels Phys. Med. Biol. 50 655-80
    • (2005) Phys. Med. Biol. , vol.50 , Issue.4 , pp. 655-680
    • Lu, W.1    Olivera, G.H.2    Chen, M.L.3    Reckwerdt, P.J.4    MacKie, T.R.5
  • 9
    • 33745481406 scopus 로고    scopus 로고
    • The convolution algorithm in IMRT
    • Mackie T R et al 2001 The convolution algorithm in IMRT 3-D Conformal and Intensity Modulated Radiation Therapy ed W Grant III, J Purdy, J Palta, B Butler and C Perez (Madison, WI: Advanced Medical Publishing) pp 179-90
    • (2001) 3-D Conformal and Intensity Modulated Radiation Therapy , pp. 179-190
    • MacKie, T.R.1
  • 12
    • 22844452234 scopus 로고    scopus 로고
    • Experimental verification of lung dose with radiochromic film: Comparison with Monte Carlo simulations and commercially available treatment planning systems
    • Paelinck L, Reynaert N, Theirens H, DeNeve W and De Wagter C 2005 Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems Phys. Med. Biol. 50 2055-69
    • (2005) Phys. Med. Biol. , vol.50 , Issue.9 , pp. 2055-2069
    • Paelinck, L.1    Reynaert, N.2    Theirens, H.3    Deneve, W.4    De Wagter, C.5
  • 14
    • 0037692078 scopus 로고    scopus 로고
    • Application of monomer/polymer gel dosimetry to study the effects of tissue inhomogeneities on intensity-modulated radiation therapy (IMRT) dose distributions
    • Vergote K, De Deene Y, Claus F, De Gersem W, Van Duyse B, Paelinck L, Achten E, De Neve W and De Wagter C 2003 Application of monomer/polymer gel dosimetry to study the effects of tissue inhomogeneities on intensity-modulated radiation therapy (IMRT) dose distributions Radiother. Oncol. 67 119-28
    • (2003) Radiother. Oncol. , vol.67 , Issue.1 , pp. 119-128
    • Vergote, K.1    De Deene, Y.2    Claus, F.3    De Gersem, W.4    Van Duyse, B.5    Paelinck, L.6    Achten, E.7    De Neve, W.8    De Wagter, C.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.