메뉴 건너뛰기




Volumn 2, Issue 1, 2009, Pages 22-32

Deriving the modulation transfer function of CT from extremely noisy edge profiles

Author keywords

CT; Edge spread function; Modulation transfer function; Noise

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; IMAGE ANALYSIS; METHODOLOGY; MODULATION TRANSFER FUNCTION; NORMAL DISTRIBUTION; PRIORITY JOURNAL; SOFT TISSUE; X RAY ANALYSIS;

EID: 64249138598     PISSN: 18650333     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12194-008-0039-9     Document Type: Article
Times cited : (36)

References (17)
  • 1
    • 0018575636 scopus 로고
    • Transfer function analysis of radiographic imaging systems
    • C Metz K Doi 1994 Transfer function analysis of radiographic imaging systems Phys Med Biol 24 1079 106
    • (1994) Phys Med Biol , vol.24 , pp. 1079-1106
    • Metz, C.1    Doi, K.2
  • 2
    • 0037600566 scopus 로고    scopus 로고
    • Can noise reduction filters improve low-radiation-dose chest images? Pilot study
    • M Kalura C Wittram M Maher A Sharma G Avinash K Karau 2003 Can noise reduction filters improve low-radiation-dose chest images? Pilot study Radiology 228 257 64
    • (2003) Radiology , vol.228 , pp. 257-264
    • Kalura, M.1    Wittram, C.2    Maher, M.3    Sharma, A.4    Avinash, G.5    Karau, K.6
  • 3
    • 33750116653 scopus 로고    scopus 로고
    • New method of evaluating edge-preserving adaptive filters for computed tomography (CT): Digital phantom method
    • M Okumura T Ota S Tsukagoshi K Katada 2006 New method of evaluating edge-preserving adaptive filters for computed tomography (CT): digital phantom method Jpn J Radiol Technol 62 971 8
    • (2006) Jpn J Radiol Technol , vol.62 , pp. 971-978
    • Okumura, M.1    Ota, T.2    Tsukagoshi, S.3    Katada, K.4
  • 4
    • 34250326683 scopus 로고    scopus 로고
    • The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT
    • J Wessling R Esseling R Raupach S Fockenberg N Osada J Gerss 2007 The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT Eur Radiol 17 1885 91
    • (2007) Eur Radiol , vol.17 , pp. 1885-1891
    • Wessling, J.1    Esseling, R.2    Raupach, R.3    Fockenberg, S.4    Osada, N.5    Gerss, J.6
  • 5
    • 0017066097 scopus 로고
    • The line spread function and modulation transfer function of a computed tomographic scanner
    • P Judy 1976 The line spread function and modulation transfer function of a computed tomographic scanner Med Phys 3 233 6
    • (1976) Med Phys , vol.3 , pp. 233-236
    • Judy, P.1
  • 6
    • 0035080793 scopus 로고    scopus 로고
    • Determination of the presampled MTF in computed tomography
    • J Boone 2001 Determination of the presampled MTF in computed tomography Med Phys 28 356 60
    • (2001) Med Phys , vol.28 , pp. 356-360
    • Boone, J.1
  • 7
  • 8
    • 0017709205 scopus 로고
    • Computed tomography with fan beam geometry
    • T Peters R Lewitt 1977 Computed tomography with fan beam geometry J Comput Assist Tomogr 1 429 36
    • (1977) J Comput Assist Tomogr , vol.1 , pp. 429-436
    • Peters, T.1    Lewitt, R.2
  • 10
    • 0021858245 scopus 로고
    • A simplified approach for modulation transfer function determinations in computed tomography
    • E Nickoloff R Riley 1976 A simplified approach for modulation transfer function determinations in computed tomography Med Phys 12 437 41
    • (1976) Med Phys , vol.12 , pp. 437-441
    • Nickoloff, E.1    Riley, R.2
  • 11
    • 0023577511 scopus 로고
    • A method for modulation transfer function determination from edge profiles with correction for finite-element differentiation
    • I Cunningham A Fenster 1987 A method for modulation transfer function determination from edge profiles with correction for finite-element differentiation Med Phys 14 533 7
    • (1987) Med Phys , vol.14 , pp. 533-537
    • Cunningham, I.1    Fenster, A.2
  • 12
    • 0141520703 scopus 로고    scopus 로고
    • Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image
    • E Buhr S Günther-Kohfahl U Neitzel 2003 Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image Med Phys 30 2323 31
    • (2003) Med Phys , vol.30 , pp. 2323-2331
    • Buhr, E.1    Günther-Kohfahl, S.2    Neitzel, U.3
  • 13
    • 0018411844 scopus 로고
    • Theoretical resolution of computer tomography systems
    • G Glover R Eisner 1979 Theoretical resolution of computer tomography systems J Comput Assist Tomogr 3 85 91
    • (1979) J Comput Assist Tomogr , vol.3 , pp. 85-91
    • Glover, G.1    Eisner, R.2
  • 14
    • 0026719031 scopus 로고
    • High-contrast resolution of CT images for bone structure analysis
    • E Durand P Rüegsegger 1992 High-contrast resolution of CT images for bone structure analysis Med Phys 19 569 73
    • (1992) Med Phys , vol.19 , pp. 569-573
    • Durand, E.1    Rüegsegger, P.2
  • 15
    • 0023199089 scopus 로고
    • The noise power spectrum of CT images
    • M Kijewski P Judy 1987 The noise power spectrum of CT images Phys Med Biol 32 565 75
    • (1987) Phys Med Biol , vol.32 , pp. 565-575
    • Kijewski, M.1    Judy, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.