Volumn 388, Issue 2, 2009, Pages 306-311

Automated immunoassay system for AFP-L3% using on-chip electrokinetic reaction and separation by affinity electrophoresis

Author keywords

Hepatocellular carcinoma; Lab on a chip; Microfluidics

Indexed keywords

CHEMICAL REACTIONS; ELECTRODYNAMICS; ELECTROPHORESIS; IMMUNOLOGY; LAB-ON-A-CHIP; SEPARATION;

EID: 64249101592     PISSN: 00032697     EISSN: 10960309     Source Type: Journal    
DOI: 10.1016/j.ab.2009.02.030     Document Type: Article
Times cited : (117)

References (22)
  • 1
    • 11944262834 scopus 로고
    • Capillary electrophoresis and sample injection systems integrated on a planar glass chip
    • Harrison D.J., Manz A., Fan Z.H., Ludi H., and Widmer H.M. Capillary electrophoresis and sample injection systems integrated on a planar glass chip. Anal. Chem. 64 (1992) 1926-1932
    • (1992) Anal. Chem. , vol.64 , pp. 1926-1932
    • Harrison, D.J.1    Manz, A.2    Fan, Z.H.3    Ludi, H.4    Widmer, H.M.5
  • 2
    • 0028407532 scopus 로고
    • Effects of injection schemes and column geometry on the performance of microchip electrophoresis devices
    • Jacobson S.C., Hergenroeder R., Koutny L.B., Warmack R.J., and Ramsey J.M. Effects of injection schemes and column geometry on the performance of microchip electrophoresis devices. Anal. Chem. 66 (1994) 1107-1113
    • (1994) Anal. Chem. , vol.66 , pp. 1107-1113
    • Jacobson, S.C.1    Hergenroeder, R.2    Koutny, L.B.3    Warmack, R.J.4    Ramsey, J.M.5
  • 3
    • 0028932361 scopus 로고
    • Microchip electrophoresis with sample stacking
    • Jacobson S.C., and Ramsey J.M. Microchip electrophoresis with sample stacking. Electrophoresis 16 (1995) 481-486
    • (1995) Electrophoresis , vol.16 , pp. 481-486
    • Jacobson, S.C.1    Ramsey, J.M.2
  • 4
    • 0029692711 scopus 로고    scopus 로고
    • Microchip electrophoretic immunoassay for serum cortisol
    • Koutny L.B., Schmalzing D., Taylor T.A., and Fuchs M. Microchip electrophoretic immunoassay for serum cortisol. Anal. Chem. 68 (1996) 18-22
    • (1996) Anal. Chem. , vol.68 , pp. 18-22
    • Koutny, L.B.1    Schmalzing, D.2    Taylor, T.A.3    Fuchs, M.4
  • 5
    • 0031081614 scopus 로고    scopus 로고
    • Microchip-based capillary electrophoresis for immunoassays: analysis of monoclonal antibodies and theophylline
    • Chiem N., and Harrison D.J. Microchip-based capillary electrophoresis for immunoassays: analysis of monoclonal antibodies and theophylline. Anal. Chem. 69 (1997) 373-378
    • (1997) Anal. Chem. , vol.69 , pp. 373-378
    • Chiem, N.1    Harrison, D.J.2
  • 6
    • 0037096666 scopus 로고    scopus 로고
    • Micro total analysis systems: I. Introduction, theory, and technology
    • Reyes D.R., Iossifidis D., Auroux P.A., and Manz A. Micro total analysis systems: I. Introduction, theory, and technology. Anal. Chem. 74 (2002) 2623-2636
    • (2002) Anal. Chem. , vol.74 , pp. 2623-2636
    • Reyes, D.R.1    Iossifidis, D.2    Auroux, P.A.3    Manz, A.4
  • 7
    • 0027567597 scopus 로고
    • Liquid-phase binding assay of human chorionic gonadotropin using high-performance liquid chromatography
    • Nakamura K., Satomura S., and Matsuura S. Liquid-phase binding assay of human chorionic gonadotropin using high-performance liquid chromatography. Anal. Chem. 65 (1993) 613-616
    • (1993) Anal. Chem. , vol.65 , pp. 613-616
    • Nakamura, K.1    Satomura, S.2    Matsuura, S.3
  • 8
    • 24644458828 scopus 로고    scopus 로고
    • Liquid-phase binding assay of α-fetoprotein using DNA-coupled antibody and capillary chip electrophoresis
    • Kawabata T., Watanabe M., Nakamura K., and Satomura S. Liquid-phase binding assay of α-fetoprotein using DNA-coupled antibody and capillary chip electrophoresis. Anal. Chem. 77 (2005) 5579-5582
    • (2005) Anal. Chem. , vol.77 , pp. 5579-5582
    • Kawabata, T.1    Watanabe, M.2    Nakamura, K.3    Satomura, S.4
  • 9
    • 42149103786 scopus 로고    scopus 로고
    • Electrokinetic analyte transport assay for α-fetoprotein immunoassay integrates mixing, reaction, and separation on-chip
    • Kawabata T., Wada H.G., Watanabe M., and Satomura S. Electrokinetic analyte transport assay for α-fetoprotein immunoassay integrates mixing, reaction, and separation on-chip. Electrophoresis 29 (2008) 1399-1406
    • (2008) Electrophoresis , vol.29 , pp. 1399-1406
    • Kawabata, T.1    Wada, H.G.2    Watanabe, M.3    Satomura, S.4
  • 10
    • 33645688547 scopus 로고    scopus 로고
    • On-chip millionfold sample stacking using transient isotachophoresis
    • Jung B., Bharadwaj R., and Santiago J.G. On-chip millionfold sample stacking using transient isotachophoresis. Anal. Chem. 78 (2006) 2319-2327
    • (2006) Anal. Chem. , vol.78 , pp. 2319-2327
    • Jung, B.1    Bharadwaj, R.2    Santiago, J.G.3
  • 11
    • 34247163461 scopus 로고    scopus 로고
    • Isotachophoresis of proteins in a networked microfluidic chip: experiment and 2-D simulation
    • Cui H.C., Dutta P., and Ivory C.F. Isotachophoresis of proteins in a networked microfluidic chip: experiment and 2-D simulation. Electrophoresis 28 (2007) 1138-1145
    • (2007) Electrophoresis , vol.28 , pp. 1138-1145
    • Cui, H.C.1    Dutta, P.2    Ivory, C.F.3
  • 13
    • 0029838117 scopus 로고    scopus 로고
    • Prognostic significance of Lens culinaris agglutinin A-reactive α-fetoprotein in small hepatocellular carcinomas
    • Yamashita F., Tanaka M., Satomura S., and Tanikawa K. Prognostic significance of Lens culinaris agglutinin A-reactive α-fetoprotein in small hepatocellular carcinomas. Gastroenterology 111 (1996) 996-1001
    • (1996) Gastroenterology , vol.111 , pp. 996-1001
    • Yamashita, F.1    Tanaka, M.2    Satomura, S.3    Tanikawa, K.4
  • 14
    • 0027422524 scopus 로고
    • A collaborative study for the evaluation of lectin-reactive α-fetoprotein in early detection of hepatocellular carcinoma
    • Taketa K., Endo Y., Sekiya C., Tanikawa K., Koji T., Taga H., Satomura S., Matsuura S., Kawai T., and Hirai H. A collaborative study for the evaluation of lectin-reactive α-fetoprotein in early detection of hepatocellular carcinoma. Cancer Res. 53 (1993) 5419-5423
    • (1993) Cancer Res. , vol.53 , pp. 5419-5423
    • Taketa, K.1    Endo, Y.2    Sekiya, C.3    Tanikawa, K.4    Koji, T.5    Taga, H.6    Satomura, S.7    Matsuura, S.8    Kawai, T.9    Hirai, H.10
  • 16
    • 0037212828 scopus 로고    scopus 로고
    • Simultaneous determination of percentage of Lens culinaris agglutinin-reactive α-fetoprotein and α-fetoprotein concentration using the LiBASys clinical auto-analyzer
    • Yamagata Y., Shimizu K., Nakamura K., Henmi F., Satomura S., Matsuura S., and Tanaka M. Simultaneous determination of percentage of Lens culinaris agglutinin-reactive α-fetoprotein and α-fetoprotein concentration using the LiBASys clinical auto-analyzer. Clin. Chim. Acta 327 (2003) 59-67
    • (2003) Clin. Chim. Acta , vol.327 , pp. 59-67
    • Yamagata, Y.1    Shimizu, K.2    Nakamura, K.3    Henmi, F.4    Satomura, S.5    Matsuura, S.6    Tanaka, M.7
  • 17
    • 0027393793 scopus 로고
    • Establishment of assay kits for the determination of microheterogeneities of α-fetoprotein using lectin-affinity electrophoresis
    • Shimizu K., Taniichi T., Satomura S., Matsuura S., Taga H., and Taketa K. Establishment of assay kits for the determination of microheterogeneities of α-fetoprotein using lectin-affinity electrophoresis. Clin. Chim. Acta 214 (1993) 3-12
    • (1993) Clin. Chim. Acta , vol.214 , pp. 3-12
    • Shimizu, K.1    Taniichi, T.2    Satomura, S.3    Matsuura, S.4    Taga, H.5    Taketa, K.6
  • 18
    • 38849096493 scopus 로고    scopus 로고
    • Controlling data quality and reproducibility of a high-sensitivity immunoassay using isotachophoresis in a microchip
    • Park C., Kazakova I., Kawabata T., Spaid M., Chien R.-L., Wada H.G., and Satomura S. Controlling data quality and reproducibility of a high-sensitivity immunoassay using isotachophoresis in a microchip. Anal. Chem. 80 (2008) 808-814
    • (2008) Anal. Chem. , vol.80 , pp. 808-814
    • Park, C.1    Kazakova, I.2    Kawabata, T.3    Spaid, M.4    Chien, R.-L.5    Wada, H.G.6    Satomura, S.7
  • 20
    • 64249154369 scopus 로고    scopus 로고
    • Wako Pure Chemical Industries, LiBASys AFP-L3% assay direction insert and product specification, Wako Pure Chemical Industries, Osaka, Japan.
    • Wako Pure Chemical Industries, LiBASys AFP-L3% assay direction insert and product specification, Wako Pure Chemical Industries, Osaka, Japan.
  • 21
    • 0032951103 scopus 로고    scopus 로고
    • Clinical utility of Lens culinaris agglutinin-reactive α-fetoprotein in small hepatocellular carcinoma: special reference to imaging diagnosis
    • Kumada T., Nakano S., Takeda I., Kiriyama S., Sone Y., Hayashi K., Katoh H., Endoh T., Sassa T., and Satomura S. Clinical utility of Lens culinaris agglutinin-reactive α-fetoprotein in small hepatocellular carcinoma: special reference to imaging diagnosis. J. Hepatol. 30 (1999) 125-130
    • (1999) J. Hepatol. , vol.30 , pp. 125-130
    • Kumada, T.1    Nakano, S.2    Takeda, I.3    Kiriyama, S.4    Sone, Y.5    Hayashi, K.6    Katoh, H.7    Endoh, T.8    Sassa, T.9    Satomura, S.10
  • 22
    • 40449121005 scopus 로고    scopus 로고
    • The degree of readiness of selected biomarkers for the early detection of hepatocellular carcinoma: notes from a recent workshop
    • Block T.M., Marrero J., Gish R.G., Sherman M., London W.T., Srivastava S., and Wagner P.D. The degree of readiness of selected biomarkers for the early detection of hepatocellular carcinoma: notes from a recent workshop. Cancer Biomarkers 4 (2008) 19-33
    • (2008) Cancer Biomarkers , vol.4 , pp. 19-33
    • Block, T.M.1    Marrero, J.2    Gish, R.G.3    Sherman, M.4    London, W.T.5    Srivastava, S.6    Wagner, P.D.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.