메뉴 건너뛰기




Volumn , Issue , 2009, Pages 141-144

Design of 1000-kV ultra-high voltage AC corona test cage in China

Author keywords

[No Author keywords available]

Indexed keywords

AC CORONAS; AC POWER TRANSMISSIONS; CORONA CAGES; CORONA EFFECTS; ELECTROMAGNETIC ENVIRONMENTS; END STRUCTURES; KEY PARAMETERS; SECTION SIZES; SURFACE GRADIENTS; TESTING FACILITIES; UHV TRANSMISSION LINES; ULTRA-HIGH VOLTAGES;

EID: 64249094201     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMCZUR.2009.4783410     Document Type: Conference Paper
Times cited : (2)

References (11)
  • 1
    • 64249165653 scopus 로고
    • Transmission line reference book
    • Electric Power Research Institute EPRI, second edition. Palo Alto, CA
    • Electric Power Research Institute (EPRI). Transmission line reference book: 345 kV and above / second edition. Palo Alto, CA. 1981.
    • (1981) kV and above , vol.345
  • 2
    • 0014781897 scopus 로고
    • Radio noise current and audible noise on short sections of UHV bundle conductors
    • G. W. Juette and L. E. Zaffanella, "Radio noise current and audible noise on short sections of UHV bundle conductors," IEEE Trans. PAS., vol. 89, No. 5, pp. 902-913, 1970.
    • (1970) IEEE Trans. PAS , vol.89 , Issue.5 , pp. 902-913
    • Juette, G.W.1    Zaffanella, L.E.2
  • 3
    • 0014818312 scopus 로고
    • Radio noise, audible noise, and corona loss of EHV and UHV transmission lines under rain: Predetermination based on cage tests
    • G. W. Juette and L. E. Zaffanella, "Radio noise, audible noise, and corona loss of EHV and UHV transmission lines under rain: predetermination based on cage tests," IEEE Trans. PAS., vol. 89, No. 6, pp. 1168-1178, 1970.
    • (1970) IEEE Trans. PAS , vol.89 , Issue.6 , pp. 1168-1178
    • Juette, G.W.1    Zaffanella, L.E.2
  • 5
    • 34250892575 scopus 로고
    • Availability of corona cage for predicting audible noise generated from HVDC transmission line
    • Y. Nakano and Y. Sunaga, "Availability of corona cage for predicting audible noise generated from HVDC transmission line," IEEE Trans. Power Del., vol. 4, No. 2, pp. 1422-1431, 1989.
    • (1989) IEEE Trans. Power Del , vol.4 , Issue.2 , pp. 1422-1431
    • Nakano, Y.1    Sunaga, Y.2
  • 6
    • 51849114702 scopus 로고
    • Availability of corona cage for predicting radio interference generated from HVDC transmission line
    • Y. Nakano and Y. Sunaga, "Availability of corona cage for predicting radio interference generated from HVDC transmission line," IEEE Trans. Power Del., vol. 5, No. 3, pp. 1436-1442, 1990.
    • (1990) IEEE Trans. Power Del , vol.5 , Issue.3 , pp. 1436-1442
    • Nakano, Y.1    Sunaga, Y.2
  • 7
    • 33846394125 scopus 로고    scopus 로고
    • Discussion on the design and application of corona cage
    • Z. Guan, M. Ma and J. Hui, "Discussion on the design and application of corona cage," High Voltage Engineering, vol. 32, No. 11, pp. 74-77, 2006.
    • (2006) High Voltage Engineering , vol.32 , Issue.11 , pp. 74-77
    • Guan, Z.1    Ma, M.2    Hui, J.3
  • 8
    • 0014779905 scopus 로고
    • Predetermination of Corona Losses Under Rain: Experimental Interpreting and Checking of a Method to Calculate Corona Losses
    • J. J. Clade and C. H. Gary, "Predetermination of Corona Losses Under Rain: Experimental Interpreting and Checking of a Method to Calculate Corona Losses," IEEE Trans. PAS., vol. 89, No. 5, pp. 853-859, 1970.
    • (1970) IEEE Trans. PAS , vol.89 , Issue.5 , pp. 853-859
    • Clade, J.J.1    Gary, C.H.2
  • 9
    • 0014818388 scopus 로고
    • Predetermination of Corona Losses Under Rain: Influence of Rain Intensity and Utilization of a Universal Chart
    • J. J. Clade and C. H. Gary, "Predetermination of Corona Losses Under Rain: Influence of Rain Intensity and Utilization of a Universal Chart," IEEE Trans. PAS., vol. 89, No. 6, pp. 1179-1185, 1970.
    • (1970) IEEE Trans. PAS , vol.89 , Issue.6 , pp. 1179-1185
    • Clade, J.J.1    Gary, C.H.2
  • 10
    • 0017417041 scopus 로고
    • A method of predicting the corona performance of conductor bundles based on cage test results
    • N. G. Trinh and P. S. Maruvada, "A method of predicting the corona performance of conductor bundles based on cage test results," IEEE Trans. PAS., vol. 98, No. 1, pp. 312-325, 1977.
    • (1977) IEEE Trans. PAS , vol.98 , Issue.1 , pp. 312-325
    • Trinh, N.G.1    Maruvada, P.S.2
  • 11
    • 64249111106 scopus 로고
    • The use of single-phase overhead test lines and test cages to evaluate the corona effects of EHV and UHV transmission lines
    • Vancouver, Canada
    • M. G. Comber and L. E. Zaffanella, "The use of single-phase overhead test lines and test cages to evaluate the corona effects of EHV and UHV transmission lines," IEEE PES Summer Meeting & EHV/UHV Conference. Vancouver, Canada. 1973.
    • (1973) IEEE PES Summer Meeting & EHV/UHV Conference
    • Comber, M.G.1    Zaffanella, L.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.