메뉴 건너뛰기




Volumn 43, Issue 11, 2007, Pages 4030-4035

Magnetic measurement of liver iron stores: Engineering aspects of a new scanning susceptometer based on high-temperature superconductivity

Author keywords

Density; Flux transformer; High T c; Imaging; Phantom; Scanning; Storage iron; Susceptibility

Indexed keywords

DENSITY; FLUX TRANSFORMER; HIGH- T C; IMAGING; PHANTOM; STORAGE IRON; SUSCEPTIBILITY;

EID: 64149129322     PISSN: 00189464     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMAG.2007.904839     Document Type: Article
Times cited : (7)

References (28)
  • 1
    • 0014115713 scopus 로고
    • Estimation of hepatic iron stores by in vivo measurement of magnetic susceptibility
    • J. H. Bauman and J. W. Harris, "Estimation of hepatic iron stores by in vivo measurement of magnetic susceptibility," J. Lab. Clin. Med., vol. 70, pp. 246-257, 1967.
    • (1967) J. Lab. Clin. Med , vol.70 , pp. 246-257
    • Bauman, J.H.1    Harris, J.W.2
  • 4
    • 0023731825 scopus 로고
    • Noninvasive methods for the early detection of hereditary hemochromatosis
    • G. M. Brittenham, "Noninvasive methods for the early detection of hereditary hemochromatosis," Ann. NY Acad. Sci., vol. 526, pp. 199-208, 1988.
    • (1988) Ann. NY Acad. Sci , vol.526 , pp. 199-208
    • Brittenham, G.M.1
  • 5
    • 1842390269 scopus 로고
    • The Hamburg biosusceptometer for liver iron quantification
    • S. J. Williamson, M. Hoke, G. Stroink, and M. Kotani, Eds. New York: Plenum
    • D. N. Paulson, R. Engelhardt, R. Fischer, and H. C. Heinrich, "The Hamburg biosusceptometer for liver iron quantification," in Advances in Biomagnetism, S. J. Williamson, M. Hoke, G. Stroink, and M. Kotani, Eds. New York: Plenum, 1989, pp. 497-500.
    • (1989) Advances in Biomagnetism , pp. 497-500
    • Paulson, D.N.1    Engelhardt, R.2    Fischer, R.3    Heinrich, H.C.4
  • 7
    • 64149119247 scopus 로고    scopus 로고
    • Magnetism in Medicine - a Handbook
    • T. Andrae and H. Nowak, Eds. Berlin, Germany: Wiley-VCH
    • R. Fischer and D. E. Farrell, "Magnetism in Medicine - a Handbook," in Liver Iron Susceptometry, T. Andrae and H. Nowak, Eds. Berlin, Germany: Wiley-VCH, 2005.
    • (2005) Liver Iron Susceptometry
    • Fischer, R.1    Farrell, D.E.2
  • 8
    • 30244454714 scopus 로고
    • Possible high-Tc superconductivity in the Ba-La-Cu-O system
    • J. G. Bednorz and K. A. Muller, "Possible high-Tc superconductivity in the Ba-La-Cu-O system," Z. Phys. B, pp. 189-193, 1986.
    • (1986) Z. Phys. B , pp. 189-193
    • Bednorz, J.G.1    Muller, K.A.2
  • 9
    • 4444266112 scopus 로고    scopus 로고
    • High-performance YBCO-coated superconductor wires
    • M. Paranthaman and I. Teruo, "High-performance YBCO-coated superconductor wires," MRS Bull., vol. 29, pp. 533-541, 2004.
    • (2004) MRS Bull , vol.29 , pp. 533-541
    • Paranthaman, M.1    Teruo, I.2
  • 11
    • 33750501179 scopus 로고    scopus 로고
    • Superconducting quantum interference device instruments and applications
    • R. L. Fagaly, "Superconducting quantum interference device instruments and applications," Rev. Sci. Instrum., vol. 77, p. 101101, 2006.
    • (2006) Rev. Sci. Instrum , vol.77 , pp. 101101
    • Fagaly, R.L.1
  • 13
    • 79955985793 scopus 로고    scopus 로고
    • Ion-beam nanotexturing of buffer layers for near-single-crystal thin-film deposition: Application to YBa Cu O - superconducting films
    • R. P. Reade, P. Berdahl, and R. E. Russo, "Ion-beam nanotexturing of buffer layers for near-single-crystal thin-film deposition: Application to YBa Cu O - superconducting films," Appl. Phys. Lett., vol. 80, pp. 1352-1354, 2002.
    • (2002) Appl. Phys. Lett , vol.80 , pp. 1352-1354
    • Reade, R.P.1    Berdahl, P.2    Russo, R.E.3
  • 17
    • 19244365628 scopus 로고    scopus 로고
    • YBCO-coated conductors manufactured by high-rate pulsed laser deposition
    • A. Usoskin and H. C. Freyhardt, "YBCO-coated conductors manufactured by high-rate pulsed laser deposition," MRS Bull., vol. 29, pp. 583-589, 2004.
    • (2004) MRS Bull , vol.29 , pp. 583-589
    • Usoskin, A.1    Freyhardt, H.C.2
  • 18
    • 12944259212 scopus 로고    scopus 로고
    • Orbital magnetic moment instability at the spin reorientation transition of Nd Fe B
    • L. M. Garcia, F. Chaboy, F. Bartolome, and J. B. Goedkoop, "Orbital magnetic moment instability at the spin reorientation transition of Nd Fe B," Phys. Rev. Lett., vol. 85, pp. 429-432, 2000.
    • (2000) Phys. Rev. Lett , vol.85 , pp. 429-432
    • Garcia, L.M.1    Chaboy, F.2    Bartolome, F.3    Goedkoop, J.B.4
  • 19
    • 0022119049 scopus 로고
    • Promising applications of neodymium boron iron magnets in electrical machines
    • Sep
    • M. A. Rahman and G. R. Slemon, "Promising applications of neodymium boron iron magnets in electrical machines," IEEE Trans. Magn., vol. MAG-16, no. 5, pp. 818-823, Sep. 1985.
    • (1985) IEEE Trans. Magn , vol.MAG-16 , Issue.5 , pp. 818-823
    • Rahman, M.A.1    Slemon, G.R.2
  • 20
    • 64149099723 scopus 로고    scopus 로고
    • See the Honeywell Magnetic Sensor Website for Device Operation and Data Sheets. [Online]. Available: http://www.ssec.honeywell.com/ magnetic/products. html
    • See the Honeywell Magnetic Sensor Website for Device Operation and Data Sheets. [Online]. Available: http://www.ssec.honeywell.com/ magnetic/products. html
  • 21
    • 0023227530 scopus 로고
    • Uniformity of liver density and nonheme (storage) iron distribution
    • B. A. Overmeyer, C. E.McClaren, and G. M. Brittenham, "Uniformity of liver density and nonheme (storage) iron distribution," Arch. Pathol. Lab. Med., vol. 111, pp. 549-554, 1987.
    • (1987) Arch. Pathol. Lab. Med , vol.111 , pp. 549-554
    • Overmeyer, B.A.1    McClaren, C.E.2    Brittenham, G.M.3
  • 22
    • 34047197473 scopus 로고    scopus 로고
    • The influence of thorax tissue in biomagnetic liver susceptometry (BLS)
    • H. Nowak, J. Haueisen, F. Giessler, and R. Huonker, Eds, Berlin, VDE Verlag
    • R. Fischer, R. Engelhardt, and P. Nielsen, "The influence of thorax tissue in biomagnetic liver susceptometry (BLS)," in Biomag. 2002: Proceedings of 13th International Conference on Biomagnetism, H. Nowak, J. Haueisen, F. Giessler, and R. Huonker, Eds., Berlin, 2002, pp. 1063-1065, VDE Verlag.
    • (2002) Biomag. 2002: Proceedings of 13th International Conference on Biomagnetism , pp. 1063-1065
    • Fischer, R.1    Engelhardt, R.2    Nielsen, P.3
  • 24
    • 1642313571 scopus 로고    scopus 로고
    • Evaluation of iron overload
    • P. D. Jensen, "Evaluation of iron overload," Brit. J. Haematology, vol. 124, pp. 697-711, 2004.
    • (2004) Brit. J. Haematology , vol.124 , pp. 697-711
    • Jensen, P.D.1
  • 26
    • 23744459788 scopus 로고    scopus 로고
    • MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients
    • J. C. Wood, C. Enriquez, N. Ghugre, J. M. Tyzka, S. Carson, M. D. Nelson, and T. D. Coates, "MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients," Blood, vol. 106, pp. 1460-1465, 2005.
    • (2005) Blood , vol.106 , pp. 1460-1465
    • Wood, J.C.1    Enriquez, C.2    Ghugre, N.3    Tyzka, J.M.4    Carson, S.5    Nelson, M.D.6    Coates, T.D.7
  • 27
    • 21244475972 scopus 로고    scopus 로고
    • Liver iron concentration evaluated by two magnetic methods: Magnetic resonance imaging and magnetic susceptometry
    • A. A. Carneiro et al., "Liver iron concentration evaluated by two magnetic methods: Magnetic resonance imaging and magnetic susceptometry," Magn. Reson. Med., vol. 54, no. 1, pp. 122-128, 2005.
    • (2005) Magn. Reson. Med , vol.54 , Issue.1 , pp. 122-128
    • Carneiro, A.A.1
  • 28
    • 29144460675 scopus 로고    scopus 로고
    • A 275 channel whole-cortex MEG system
    • H. Nowak, J. Haueisen, F. Giessler, and R. Huonker, Eds, Berlin, Germany, VDE Verlag
    • A. A. Fife et al., "A 275 channel whole-cortex MEG system," in Biomag 2002: Proceedings of 13th International Conference on Biomagnetism, H. Nowak, J. Haueisen, F. Giessler, and R. Huonker, Eds., Berlin, Germany, 2002, VDE Verlag.
    • (2002) Biomag 2002: Proceedings of 13th International Conference on Biomagnetism
    • Fife, A.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.