메뉴 건너뛰기




Volumn 12, Issue 1, 2009, Pages 25-33

Stresses in peripheral arteries following stent placement: a finite element analysis

Author keywords

Artery bending; Finite element analysis; Peripheral stent; Restenosis

Indexed keywords

ARTERY; ARTICLE; BIOLOGICAL MODEL; BLOOD VESSEL PROSTHESIS; COMPUTER SIMULATION; FINITE ELEMENT ANALYSIS; GRAFT OCCLUSION; HUMAN; IMPLANTATION; MECHANICAL STRESS; PATHOPHYSIOLOGY; PHYSIOLOGY; STENT; YOUNG MODULUS;

EID: 63849324013     PISSN: 10255842     EISSN: 14768259     Source Type: Journal    
DOI: 10.1080/10255840802136135     Document Type: Article
Times cited : (65)

References (46)
  • 1
    • 0037593628 scopus 로고    scopus 로고
    • Fracture of popliteal artery stents
    • Babalik E, Gulbaran M, Gurmen T, Ozturk S. 2003. Fracture of popliteal artery stents. Circ J. 67(7):643-645.
    • (2003) Circ J , vol.67 , Issue.7 , pp. 643-645
    • Babalik, E.1    Gulbaran, M.2    Gurmen, T.3    Ozturk, S.4
  • 2
    • 33748250062 scopus 로고    scopus 로고
    • Intramural stress increases exponentially with stent diameter: a stress threshold for neointimal hyperplasia
    • Ballyk PD. 2006. Intramural stress increases exponentially with stent diameter: a stress threshold for neointimal hyperplasia. J Vasc Interv Radiol. 17(7):1139-1145.
    • (2006) J Vasc Interv Radiol , vol.17 , Issue.7 , pp. 1139-1145
    • Ballyk, P.D.1
  • 3
    • 33750378236 scopus 로고    scopus 로고
    • Effects of stent design parameters on normal artery wall mechanics
    • Bedoya J, Meyer CA, Timmins LH, Moreno MR, Moore JE. 2006. Effects of stent design parameters on normal artery wall mechanics. J Biomech Eng. 128(5):757-765.
    • (2006) J Biomech Eng , vol.128 , Issue.5 , pp. 757-765
    • Bedoya, J.1    Meyer, C.A.2    Timmins, L.H.3    Moreno, M.R.4    Moore, J.E.5
  • 6
    • 10044238835 scopus 로고    scopus 로고
    • Finite element simulation of slotted tube (stent) with the presence of plaque and artery by balloon expansion
    • Chua SND, MacDonald BJ, Hashmi MSJ. 2004. Finite element simulation of slotted tube (stent) with the presence of plaque and artery by balloon expansion. J Mater Process Technol. 155-56:1772-1779.
    • (2004) J Mater Process Technol , vol.155-156 , pp. 1772-1779
    • Chua, S.N.D.1    MacDonald, B.J.2    Hashmi, M.S.J.3
  • 7
    • 67649113561 scopus 로고    scopus 로고
    • Finite element simulation of the free expansion of the Cypher stent crimped on a tri-folded balloon
    • De Beule P, Mortier P, Segers SG, Carlier B, Verhegghe R, Van Impe R, Verdonck P. 2006. Finite element simulation of the free expansion of the Cypher stent crimped on a tri-folded balloon. J Biomech. 39(Suppl. 1):S297.
    • (2006) J Biomech , vol.39 , Issue.SUPPL. 1
    • De Beule, P.1    Mortier, P.2    Segers, S.G.3    Carlier, B.4    Verhegghe, R.5    Van Impe, R.6    Verdonck, P.7
  • 9
    • 0033759162 scopus 로고    scopus 로고
    • Dynamics of human coronary arterial motion and its potential role in coronary atherogenesis
    • Ding Z, Friedman MH. 2000a. Dynamics of human coronary arterial motion and its potential role in coronary atherogenesis. J Biomech Eng. 122(5):488-492.
    • (2000) J Biomech Eng , vol.122 , Issue.5 , pp. 488-492
    • Ding, Z.1    Friedman, M.H.2
  • 10
    • 0034534539 scopus 로고    scopus 로고
    • Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms
    • Ding Z, Friedman MH. 2000b. Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms. Int J Card Imaging. 16(5):331-346.
    • (2000) Int J Card Imaging , vol.16 , Issue.5 , pp. 331-346
    • Ding, Z.1    Friedman, M.H.2
  • 11
    • 0035988836 scopus 로고    scopus 로고
    • Coronary artery dynamics in vivo
    • Ding Z, Zhu H, Friedman MH. 2002. Coronary artery dynamics in vivo. Ann Biomed Eng. 30(4):419-429.
    • (2002) Ann Biomed Eng , vol.30 , Issue.4 , pp. 419-429
    • Ding, Z.1    Zhu, H.2    Friedman, M.H.3
  • 13
    • 0036695745 scopus 로고    scopus 로고
    • A comparison of balloon- and self-expanding stents
    • Duerig TW, Wholey M. 2002. A comparison of balloon- and self-expanding stents. Minim Invasive Ther Allied Technol. 11(4):173-178.
    • (2002) Minim Invasive Ther Allied Technol , vol.11 , Issue.4 , pp. 173-178
    • Duerig, T.W.1    Wholey, M.2
  • 14
    • 33646172838 scopus 로고    scopus 로고
    • Stent modeling using immersed finite element method
    • Gay M, Zhang L, Liu WK. 2006. Stent modeling using immersed finite element method. Comput Methods Appl Mech Eng. 195(33-36):4358-4370.
    • (2006) Comput Methods Appl Mech Eng , vol.195 , Issue.33-36 , pp. 4358-4370
    • Gay, M.1    Zhang, L.2    Liu, W.K.3
  • 15
    • 0030802995 scopus 로고    scopus 로고
    • Popliteal artery compression and force of active plantar flexion in young healthy volunteers
    • Hoffmann U, Vetter J, Rainoni L, Leu AJ, Bollinger A. 1997. Popliteal artery compression and force of active plantar flexion in young healthy volunteers. J Vasc Surg. 26(2):281-287.
    • (1997) J Vasc Surg , vol.26 , Issue.2 , pp. 281-287
    • Hoffmann, U.1    Vetter, J.2    Rainoni, L.3    Leu, A.J.4    Bollinger, A.5
  • 16
    • 0034434740 scopus 로고    scopus 로고
    • A new constitutive framework for arterial wall mechanics and a comparative study of material models
    • Holzapfel GA, Gasser TC, Ogden RW. 2000. A new constitutive framework for arterial wall mechanics and a comparative study of material models. J Elasticity. 61(1-3):1-48.
    • (2000) J Elasticity , vol.61 , Issue.1-3 , pp. 1-48
    • Holzapfel, G.A.1    Gasser, T.C.2    Ogden, R.W.3
  • 17
    • 16344362656 scopus 로고    scopus 로고
    • Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs
    • Holzapfel GA, Stadler M, Gasser TC. 2005. Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs. J Biomech Eng. 127(1):166-180.
    • (2005) J Biomech Eng , vol.127 , Issue.1 , pp. 166-180
    • Holzapfel, G.A.1    Stadler, M.2    Gasser, T.C.3
  • 19
    • 12144277426 scopus 로고    scopus 로고
    • Biomechanical incompatibility of popliteal stent placement
    • Kröger K, Santosa F, Goyen M. 2004. Biomechanical incompatibility of popliteal stent placement. J Endovasc Ther. 11(6):686-694.
    • (2004) J Endovasc Ther , vol.11 , Issue.6 , pp. 686-694
    • Kröger, K.1    Santosa, F.2    Goyen, M.3
  • 21
    • 20444475661 scopus 로고    scopus 로고
    • Cardiovascular stent design and vessel stresses: a finite element analysis
    • Lally C, Dolan F, Prendergast PJ. 2005. Cardiovascular stent design and vessel stresses: a finite element analysis. J Biomech. 38(8):1574-1581.
    • (2005) J Biomech , vol.38 , Issue.8 , pp. 1574-1581
    • Lally, C.1    Dolan, F.2    Prendergast, P.J.3
  • 23
    • 0013887788 scopus 로고
    • Alterations with age in the viscoelastic properties of human arterial walls
    • Learoyd BM, Taylor MG. 1966. Alterations with age in the viscoelastic properties of human arterial walls. Circ Res. 18(3):278-292.
    • (1966) Circ Res , vol.18 , Issue.3 , pp. 278-292
    • Learoyd, B.M.1    Taylor, M.G.2
  • 24
    • 25444471259 scopus 로고    scopus 로고
    • Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery
    • Liang DK, Yang DZ, Qi M, Wang WQ. 2005. Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery. Int J Cardiol. 104(3):314-318.
    • (2005) Int J Cardiol , vol.104 , Issue.3 , pp. 314-318
    • Liang, D.K.1    Yang, D.Z.2    Qi, M.3    Wang, W.Q.4
  • 26
    • 0028947260 scopus 로고
    • Percutaneous transluminal angioplasty in femoral artery occlusions: primary and long-term results in 107 claudicant patients using femoral and popliteal catheterization techniques
    • Matsi PJ, Manninen HI, Soder HK, Mustonen P, Kouri J. 1995. Percutaneous transluminal angioplasty in femoral artery occlusions: primary and long-term results in 107 claudicant patients using femoral and popliteal catheterization techniques. Clin Radiol. 50(4):237-244.
    • (1995) Clin Radiol , vol.50 , Issue.4 , pp. 237-244
    • Matsi, P.J.1    Manninen, H.I.2    Soder, H.K.3    Mustonen, P.4    Kouri, J.5
  • 31
    • 0034880263 scopus 로고    scopus 로고
    • Update on peripheral vascular diseases: from smoking cessation to stenting
    • Mukherjee D, Yadav JS. 2001. Update on peripheral vascular diseases: from smoking cessation to stenting. Cleve Clin J Med. 68(8):723-733.
    • (2001) Cleve Clin J Med , vol.68 , Issue.8 , pp. 723-733
    • Mukherjee, D.1    Yadav, J.S.2
  • 33
    • 0142231887 scopus 로고    scopus 로고
    • Analysis of prolapse in cardiovascular stents: a constitutive equation for vascular tissue and finite-element modelling
    • Prendergast PJ, Lally C, Daly S, Reid AJ, Lee TC, Quinn D, Dolan F. 2003. Analysis of prolapse in cardiovascular stents: a constitutive equation for vascular tissue and finite-element modelling. J Biomech Eng. 125(5):692-699.
    • (2003) J Biomech Eng , vol.125 , Issue.5 , pp. 692-699
    • Prendergast, P.J.1    Lally, C.2    Daly, S.3    Reid, A.J.4    Lee, T.C.5    Quinn, D.6    Dolan, F.7
  • 34
    • 0343550424 scopus 로고    scopus 로고
    • Human femoral artery diameter in relation to knee extensor muscle mass, peak blood flow, and oxygen uptake
    • Radegran G, Saltin B. 2000. Human femoral artery diameter in relation to knee extensor muscle mass, peak blood flow, and oxygen uptake. Am J Physiol Heart Circ Physiol. 278(1):H162-H167.
    • (2000) Am J Physiol Heart Circ Physiol , vol.278 , Issue.1
    • Radegran, G.1    Saltin, B.2
  • 38
    • 84993900563 scopus 로고
    • Pigs, dogs, baboons and man; lessons in stenting from animal studies
    • Schwartz R, Holmes DR. 1994. Pigs, dogs, baboons and man; lessons in stenting from animal studies. J Interv Cardiol. 7:355-368.
    • (1994) J Interv Cardiol , vol.7 , pp. 355-368
    • Schwartz, R.1    Holmes, D.R.2
  • 39
    • 32544456472 scopus 로고    scopus 로고
    • A case of popliteal stent fracture with pseudoaneurysm formation
    • Solis J, Allaqaband S, Bajwa T. 2006. A case of popliteal stent fracture with pseudoaneurysm formation. Catheter Cardiovasc Interv. 67(2):319-322.
    • (2006) Catheter Cardiovasc Interv , vol.67 , Issue.2 , pp. 319-322
    • Solis, J.1    Allaqaband, S.2    Bajwa, T.3
  • 40
    • 67649106953 scopus 로고    scopus 로고
    • Dynamics of endovascular stent expansion. Massachusetts: Massachusetts Institute of Technology
    • Squire JC. 2000. Dynamics of endovascular stent expansion. Massachusetts: Massachusetts Institute of Technology.
    • (2000)
  • 41
    • 0030664741 scopus 로고    scopus 로고
    • Femoropopliteal artery stent placement: evaluation of long-term success
    • Strecker EP, Boos IB, Gottmann D. 1997. Femoropopliteal artery stent placement: evaluation of long-term success. Radiology. 205(2):375-383.
    • (1997) Radiology , vol.205 , Issue.2 , pp. 375-383
    • Strecker, E.P.1    Boos, I.B.2    Gottmann, D.3
  • 42
    • 33845296472 scopus 로고    scopus 로고
    • Simulation and experimental observation of contact conditions between stents and artery models
    • Takashima K, Kitou T, Mori K, Ikeuchi K. 2007. Simulation and experimental observation of contact conditions between stents and artery models. Med Eng Phys. 29(3):326-335.
    • (2007) Med Eng Phys , vol.29 , Issue.3 , pp. 326-335
    • Takashima, K.1    Kitou, T.2    Mori, K.3    Ikeuchi, K.4
  • 43
    • 27744557004 scopus 로고    scopus 로고
    • Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method
    • Wang WQ, Liang DK, Yang DZ, Qi M. 2006. Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method. J Biomech. 39(1):21-32.
    • (2006) J Biomech , vol.39 , Issue.1 , pp. 21-32
    • Wang, W.Q.1    Liang, D.K.2    Yang, D.Z.3    Qi, M.4
  • 44
    • 0034887346 scopus 로고    scopus 로고
    • Dynamic curvature strongly affects wall shear rates in a coronary artery bifurcation model
    • Weydahl ES, Moore JE. 2001. Dynamic curvature strongly affects wall shear rates in a coronary artery bifurcation model. J Biomech. 34(9):1189-1196.
    • (2001) J Biomech , vol.34 , Issue.9 , pp. 1189-1196
    • Weydahl, E.S.1    Moore, J.E.2
  • 45
    • 32344437395 scopus 로고    scopus 로고
    • Fatigue and fracture in materials used for micro-scale biomedical components
    • Wiersma S, Dolan F, Taylor D. 2006. Fatigue and fracture in materials used for micro-scale biomedical components. Biomed Mater Eng. 16(2):137-146.
    • (2006) Biomed Mater Eng , vol.16 , Issue.2 , pp. 137-146
    • Wiersma, S.1    Dolan, F.2    Taylor, D.3
  • 46
    • 0037855972 scopus 로고    scopus 로고
    • Effects of cardiac motion on right coronary artery hemodynamics
    • Zeng D, Ding Z, Friedman MH, Ethier CR. 2003. Effects of cardiac motion on right coronary artery hemodynamics. Ann Biomed Eng. 31(4):420-429.
    • (2003) Ann Biomed Eng , vol.31 , Issue.4 , pp. 420-429
    • Zeng, D.1    Ding, Z.2    Friedman, M.H.3    Ethier, C.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.