메뉴 건너뛰기




Volumn 223, Issue 2, 2009, Pages 237-248

Optimization of the stress distribution in ceramic femoral heads by means of finite element methods

Author keywords

Ceramic femoral head; Computer aided optimization; Finite element analysis; Stress concentration

Indexed keywords

ASYMMETRIC LOADING; AXISYMMETRIC LOADS; BURST LOADS; CERAMIC BALLS; CERAMIC FEMORAL HEAD; CERAMIC FEMORAL HEADS; COMPUTER-AIDED OPTIMIZATION; COMPUTER-AIDED OPTIMIZATIONS; CONTACT AREAS; FILLET RADIUS; FINITE ELEMENT ANALYSIS; FRACTURE LOAD; GLOBAL MAXIMUM; HIGH STRESS; HOOP STRESS; IN-VIVO; LOAD ANGLE; LOCAL STRESS; LOCAL STRESS CONCENTRATION; NOTCH STRESS; STRESS DISTRIBUTION; TOTAL HIP REPLACEMENTS;

EID: 63849209989     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM429     Document Type: Article
Times cited : (16)

References (19)
  • 1
    • 67649517369 scopus 로고    scopus 로고
    • Garino, J. P. Ceramic component fracture: trends and recommendations with modern components based on improved reporting methods. In Biocera- mics and alternative bearings in joint arthroplasty, Proceedings of the Tenth International BIOLOX Symposium (Eds J. A. D'Antonio and M. Dietrich), 2005, pp. 157-168 (Springer-Verlag, Berlin).
    • Garino, J. P. Ceramic component fracture: trends and recommendations with modern components based on improved reporting methods. In Biocera- mics and alternative bearings in joint arthroplasty, Proceedings of the Tenth International BIOLOX Symposium (Eds J. A. D'Antonio and M. Dietrich), 2005, pp. 157-168 (Springer-Verlag, Berlin).
  • 2
    • 0029558228 scopus 로고
    • Fracture of an alumina ceramic head in total hip arthroplasty
    • Higuchi, F., Shiba, N., Inoue, A., and Wakebe, I. Fracture of an alumina ceramic head in total hip arthroplasty. J. Arthroplasty, 1995, 10(6), 851-854.
    • (1995) J. Arthroplasty , vol.10 , Issue.6 , pp. 851-854
    • Higuchi, F.1    Shiba, N.2    Inoue, A.3    Wakebe, I.4
  • 3
    • 0029614361 scopus 로고
    • Ceramic head failure
    • Krikler, S. and Schatzker, J. Ceramic head failure. J. Arthroplasty, 1995, 10(6), 860-862.
    • (1995) J. Arthroplasty , vol.10 , Issue.6 , pp. 860-862
    • Krikler, S.1    Schatzker, J.2
  • 4
    • 0001166249 scopus 로고    scopus 로고
    • Survival rate and reliability of ceramic femoral heads for total hip arthroplasty
    • Willmann, G. Survival rate and reliability of ceramic femoral heads for total hip arthroplasty. Materialwissenschaft Werkstofftechnik, 1998, 29(10), 595-604.
    • (1998) Materialwissenschaft Werkstofftechnik , vol.29 , Issue.10 , pp. 595-604
    • Willmann, G.1
  • 5
    • 67649532979 scopus 로고    scopus 로고
    • Willmann, G. Fiction and facts concerning the reliability of ceramics in THR. In Ceramics in orthopaedics, Proceedings of the Eighth International BIOLOX Symposium (Eds H. Zippel and M. Dietrich), 2003, pp. 193-196 (Steinkopff-Verlag, Berlin).
    • Willmann, G. Fiction and facts concerning the reliability of ceramics in THR. In Ceramics in orthopaedics, Proceedings of the Eighth International BIOLOX Symposium (Eds H. Zippel and M. Dietrich), 2003, pp. 193-196 (Steinkopff-Verlag, Berlin).
  • 6
    • 67649526763 scopus 로고    scopus 로고
    • Richter, H. G. Application of proof-testing to ceramic hip joint heads. In Ceramic wear couples, Proceedings of the Third International BIOLOX Symposium (Ed. W. Puhl), 1998, pp. 7-12 (Ferdinand Enke Verlag, Stuttgart).
    • Richter, H. G. Application of proof-testing to ceramic hip joint heads. In Ceramic wear couples, Proceedings of the Third International BIOLOX Symposium (Ed. W. Puhl), 1998, pp. 7-12 (Ferdinand Enke Verlag, Stuttgart).
  • 7
    • 0141608581 scopus 로고    scopus 로고
    • Improvement of the reliability of ceramic hip joint implants
    • Weisse, B., Zahner, M., Weber, W., and Rieger, W. Improvement of the reliability of ceramic hip joint implants. J. Biomechanics, 2003, 36(11), 1633-1639.
    • (2003) J. Biomechanics , vol.36 , Issue.11 , pp. 1633-1639
    • Weisse, B.1    Zahner, M.2    Weber, W.3    Rieger, W.4
  • 8
    • 67649545436 scopus 로고    scopus 로고
    • ATZ - A new material with a high potential in joint replacement
    • Begand, S., Oberbach, T., and Glien, W. ATZ - A new material with a high potential in joint replacement. Bioceramics, 2005, 17, 983-986.
    • (2005) Bioceramics , vol.17 , pp. 983-986
    • Begand, S.1    Oberbach, T.2    Glien, W.3
  • 10
    • 0036433798 scopus 로고    scopus 로고
    • Fractography of bioceramics
    • Trans Tech Publications, Stata-Zurich
    • Richter, H. G. Fractography of bioceramics. In Fractography of advanced ceramics, 2002, pp. 157-180 (Trans Tech Publications, Stata-Zurich).
    • (2002) Fractography of advanced ceramics , pp. 157-180
    • Richter, H.G.1
  • 11
    • 67649557750 scopus 로고    scopus 로고
    • Konstruktions-, Rechen- und Priifverfahren fUr verbesserte Lang- zeit-Zuveriassigkeit von Huft- und Kniegelenk- prothesen aus neuzeitlichen Werkstoffen
    • Maier, H. R. and Krauth, A. Konstruktions-, Rechen- und Priifverfahren fUr verbesserte Lang- zeit-Zuveriassigkeit von Huft- und Kniegelenk- prothesen aus neuzeitlichen Werkstoffen. For- schungsbericht T 83-278, 1983.
    • For- schungsbericht , vol.T 83-278 , pp. 1983
    • Maier, H.R.1    Krauth, A.2
  • 12
    • 67649554577 scopus 로고    scopus 로고
    • Rieger, W. Ceramics in orthopedics - 30 years of evolution and experience. In Proceedings of the World Tribology Forum on Arthroplasty (Eds C. Rieker, S. Oberholzer, and U. Wyss), 2001, pp. 1-14 (Verlag Hans Huber, Bern).
    • Rieger, W. Ceramics in orthopedics - 30 years of evolution and experience. In Proceedings of the World Tribology Forum on Arthroplasty (Eds C. Rieker, S. Oberholzer, and U. Wyss), 2001, pp. 1-14 (Verlag Hans Huber, Bern).
  • 13
    • 0028379017 scopus 로고
    • The safety of ceramic balls on metal stems in hip-arthroplasty
    • Heimke, G. The safety of ceramic balls on metal stems in hip-arthroplasty. Advd Mater., 1994, 6(2), 165-170.
    • (1994) Advd Mater , vol.6 , Issue.2 , pp. 165-170
    • Heimke, G.1
  • 14
    • 57649189977 scopus 로고    scopus 로고
    • Implants for surgery - partial and total hip-joint prostheses: Determination of resistance to static load ofmodular femoral heads,
    • ISO 7206-10, International Standardization Organization, Geneva
    • ISO 7206-10. Implants for surgery - partial and total hip-joint prostheses: determination of resistance to static load ofmodular femoral heads, 2003 (International Standardization Organization, Geneva).
    • (2003)
  • 16
    • 0031906050 scopus 로고    scopus 로고
    • The structural optimization of trees
    • Mattheck, C. and Bethge, K. The structural optimization of trees. Naturwissenschaften, 1998, 85(1), 1-10.
    • (1998) Naturwissenschaften , vol.85 , Issue.1 , pp. 1-10
    • Mattheck, C.1    Bethge, K.2
  • 17
    • 8744222376 scopus 로고    scopus 로고
    • CAO- shape optimisation of a fillet with a complex, time dependent loading
    • WIT Press, Southampton
    • Ledermann, M., Tesari, I., and Mattheck, C. CAO- shape optimisation of a fillet with a complex, time dependent loading. In Computer aided optimum design of structures, VII, 2001, pp. 203-210 (WIT Press, Southampton).
    • (2001) Computer aided optimum design of structures, VII , pp. 203-210
    • Ledermann, M.1    Tesari, I.2    Mattheck, C.3
  • 18
    • 33646773623 scopus 로고    scopus 로고
    • Teacher tree: The evolution of notch shape optimization from complex to simple
    • Mattheck, C. Teacher tree: the evolution of notch shape optimization from complex to simple. Engng Fracture Mechanics, 2006, 73(12), 1732-1742.
    • (2006) Engng Fracture Mechanics , vol.73 , Issue.12 , pp. 1732-1742
    • Mattheck, C.1
  • 19
    • 67649536261 scopus 로고    scopus 로고
    • Abaqus V. 6.5, analysis user's manual, I-V, 2004 (Hibbit, Karlsson & Sorensen, Pawtucket, Rhode Island).
    • Abaqus V. 6.5, analysis user's manual, I-V, 2004 (Hibbit, Karlsson & Sorensen, Pawtucket, Rhode Island).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.