메뉴 건너뛰기




Volumn 133, Issue 2, 2009, Pages 73-80

Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter

Author keywords

[No Author keywords available]

Indexed keywords

CALCIUM SULFATE; NUCLEAR FUEL; PHOSPHORUS; POLITEF;

EID: 63849130507     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncp019     Document Type: Article
Times cited : (5)

References (17)
  • 2
    • 63849224938 scopus 로고    scopus 로고
    • Adequacy of external dosimetry methods and suitability of personal dosemeters for workplace radiation fields
    • Health and Safety Executive
    • Bartlett, D. T. and Tanner, R. J. Adequacy of external dosimetry methods and suitability of personal dosemeters for workplace radiation fields. Research Report 385, Health and Safety Executive (2005).
    • (2005) Research Report , vol.385
    • Bartlett, D.T.1    Tanner, R.J.2
  • 9
    • 0018194576 scopus 로고
    • A thermoluminescent fast-neutron dosemeter based on pellets of CaSO4:DY mixed with sulphur
    • Pradhan, A. S., Bhatt, R. C., Lakshmanan, A. R., Bhuwan, Chandra and Shinde, S. S. A thermoluminescent fast-neutron dosemeter based on pellets of CaSO4:DY mixed with sulphur. Phys. Med. Biol. 23, 723 (1978).
    • (1978) Phys. Med. Biol , vol.23 , pp. 723
    • Pradhan, A.S.1    Bhatt, R.C.2    Lakshmanan, A.R.3    Bhuwan, C.4    Shinde, S.S.5
  • 10
    • 13044274528 scopus 로고
    • Development of neutron sensitive Teflon TLD discs for personnel monitoring
    • Pradhan, A. S., Bhatt, B. C. and Bhatt, R. C. Development of neutron sensitive Teflon TLD discs for personnel monitoring. Bull. Radiat. Prot. 11, 47-52 (1988).
    • (1988) Bull. Radiat. Prot , vol.11 , pp. 47-52
    • Pradhan, A.S.1    Bhatt, B.C.2    Bhatt, R.C.3
  • 14
    • 63849313053 scopus 로고    scopus 로고
    • International Electrotecnical Commission. Thermoluminescent dosimetry system for personal and environmental monitoring. IEC Technical Sub Committee No. 45B: Radiation Protection Instrumentation, No. CEI/IEC 61066 (1991).
    • International Electrotecnical Commission. Thermoluminescent dosimetry system for personal and environmental monitoring. IEC Technical Sub Committee No. 45B: Radiation Protection Instrumentation, No. CEI/IEC 61066 (1991).
  • 15
    • 0017535910 scopus 로고
    • Progress in albedo neutron dosimetry
    • Piesch, E. Progress in albedo neutron dosimetry. Nucl. Inst. Meth. 145, 613-619 (1977).
    • (1977) Nucl. Inst. Meth , vol.145 , pp. 613-619
    • Piesch, E.1
  • 17
    • 34547117376 scopus 로고    scopus 로고
    • Development of an algorithm for TLD badge system for dosimetry in the field of X and gamma radiation in terms of Hp(10)
    • Bakshi, A. K., Srivastava, K., Varadharajan, G., Pradhan, A. S. and Kher, R. K. Development of an algorithm for TLD badge system for dosimetry in the field of X and gamma radiation in terms of Hp(10). Radiat. Prot. Dosim. 123, 148-155 (2007).
    • (2007) Radiat. Prot. Dosim , vol.123 , pp. 148-155
    • Bakshi, A.K.1    Srivastava, K.2    Varadharajan, G.3    Pradhan, A.S.4    Kher, R.K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.