메뉴 건너뛰기




Volumn , Issue , 2008, Pages 277-280

Mismatch reduction with relative reset in integrate-and-fire photo-pixel array

Author keywords

[No Author keywords available]

Indexed keywords

BIO-INSPIRED VISIONS; CORRELATED DOUBLE SAMPLINGS; FIXED CHARGES; IMAGERS; INTEGRATE AND FIRES; MISMATCH ERRORS; MONTE CARLO SIMULATIONS; NOISE REDUCTION TECHNIQUES; PIXEL ARRAYS; SELF-TIMED; STATISTIC PARAMETERS; THRESHOLD MISMATCHES; VISION SENSORS;

EID: 63649148627     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BIOCAS.2008.4696928     Document Type: Conference Paper
Times cited : (10)

References (8)
  • 1
    • 0037319622 scopus 로고    scopus 로고
    • A biomorphic digital image sensor
    • E. Culurciello, R. Etienne-Cummings, and K. Boahen, "A biomorphic digital image sensor," IEEE JSSC, vol. 38, no. 2, pp. 281-294, 2003.
    • (2003) IEEE JSSC , vol.38 , Issue.2 , pp. 281-294
    • Culurciello, E.1    Etienne-Cummings, R.2    Boahen, K.3
  • 4
    • 0036286954 scopus 로고    scopus 로고
    • An on/off transient imager with event-driven, asynchronous read-out
    • Phoenix, AZ, USA
    • J. Kramer, "An on/off transient imager with event-driven, asynchronous read-out." in IEEE International Symposium on Circuits and Systems, vol. II, Phoenix, AZ, USA, 2002, pp. 165-168.
    • (2002) IEEE International Symposium on Circuits and Systems , vol.2 , pp. 165-168
    • Kramer, J.1
  • 5
    • 39749084094 scopus 로고    scopus 로고
    • A 128×128 120db 30mw asynchronous vision sensor that responds to relative intensity change
    • P. Lichtsteiner, C. Posch, and T. Delbruck, "A 128×128 120db 30mw asynchronous vision sensor that responds to relative intensity change," in ISSCC Digest of Technical Papers, 2006, pp. 508-509.
    • (2006) ISSCC Digest of Technical Papers , pp. 508-509
    • Lichtsteiner, P.1    Posch, C.2    Delbruck, T.3
  • 7
    • 84893741813 scopus 로고    scopus 로고
    • A new correlated double sampling (CDS) technique for low voltag design environment in advanced CMOS technology
    • C. Xu, S. Chao, and M. Chan, "A new correlated double sampling (CDS) technique for low voltag design environment in advanced CMOS technology," in Proc. of ESSIRC, 2002, pp. 117-120.
    • (2002) Proc. of ESSIRC , pp. 117-120
    • Xu, C.1    Chao, S.2    Chan, M.3
  • 8
    • 63649141281 scopus 로고    scopus 로고
    • Analog to interval encoder with active use of gate leakage for an implanted blood-sugar sensor
    • accepted for publication
    • P. Häfliger and E. Johannessen, "Analog to interval encoder with active use of gate leakage for an implanted blood-sugar sensor," in Proc IEEE Biomedical Circuits and Systems, 2008, accepted for publication.
    • (2008) Proc IEEE Biomedical Circuits and Systems
    • Häfliger, P.1    Johannessen, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.