메뉴 건너뛰기




Volumn 31, Issue 10, 2008, Pages 987-

Assessment of accuracy of acetabular cup orientation in CT-free navigated total hip arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULOPLASTY; ACETABULUM; ARTICLE; CLINICAL ARTICLE; COMPUTER AIDED DESIGN; COMPUTER ASSISTED TOMOGRAPHY; DIGITAL IMAGING; HUMAN; ILIAC BONE; IMAGE PROCESSING; PALPATION; POSTOPERATIVE CARE; PUBIS SYMPHYSIS; TOTAL HIP PROSTHESIS; CLINICAL TRIAL; COMPUTER ASSISTED SURGERY; EQUIPMENT; EQUIPMENT DESIGN; HIP ARTHROPLASTY; IMPLANTATION; INSTRUMENTATION; METHODOLOGY; PATHOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TREATMENT OUTCOME;

EID: 63649138310     PISSN: 01477447     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (21)

References (16)
  • 3
    • 0031855096 scopus 로고    scopus 로고
    • Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration
    • DOI 10.1016/S0883-5403(98)90052-3
    • Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty. 1998; 13(5):530-534. (Pubitemid 28380811)
    • (1998) Journal of Arthroplasty , vol.13 , Issue.5 , pp. 530-534
    • Kennedy, J.G.1    Rogers, W.B.2    Soffe, K.E.3    Sullivan, R.J.4    Griffen, D.G.5    Sheehan, L.J.6
  • 4
    • 0025679123 scopus 로고
    • Dislocation after total hip arthroplasty. Causes and prevention
    • McCollum DE, Gray WJ. Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res. 1990; (261):159-170.
    • (1990) Clin Orthop Relat Res , vol.261 , pp. 159-170
    • McCollum, D.E.1    Gray, W.J.2
  • 6
    • 0036068245 scopus 로고    scopus 로고
    • Reduction in variability of acetabular cup abduction using computer assisted surgery: A prospective and randomized study
    • DOI 10.1002/igs.10033
    • Leenders T, Vandevelde D, Mahieu G, Nuyts R. Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study. Comput Aided Surg. 2002; 7(2):99-106. (Pubitemid 34773624)
    • (2002) Computer Aided Surgery , vol.7 , Issue.2 , pp. 99-106
    • Leenders, T.1    Vandevelde, D.2    Mahieu, G.3    Nuyts, R.4
  • 7
    • 0032178167 scopus 로고    scopus 로고
    • The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment
    • DiGioia AM, Jaramaz B, Blackwell M, et al. The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res. 1998; (355):8-22.
    • (1998) Clin Orthop Relat Res , vol.355 , pp. 8-22
    • Digioia, A.M.1    Jaramaz, B.2    Blackwell, M.3
  • 8
    • 0033050961 scopus 로고    scopus 로고
    • Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs
    • DOI 10.1302/0301-620X.81B3.9067
    • Pradhan R. Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. J Bone Joint Surg Br. 1999; 81(3):431-435. (Pubitemid 29245895)
    • (1999) Journal of Bone and Joint Surgery - Series B , vol.81 , Issue.3 , pp. 431-435
    • Pradhan, R.1
  • 9
    • 0027479381 scopus 로고
    • The definition and measurement of acetabular orientation
    • Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993; 75(2):228-232. (Pubitemid 23087178)
    • (1993) Journal of Bone and Joint Surgery - Series B , vol.75 , Issue.2 , pp. 228-232
    • Murray, D.W.1
  • 10
    • 3242798895 scopus 로고    scopus 로고
    • Sensitivity of femoral orientation estimates to condylar surface and MR image plane location
    • DOI 10.1002/jmri.20106
    • Shibanuma N, Sheehan FT, Lipsky PE, Stanhope SJ. Sensitivity of femoral orientation estimates to condylar surface and MR image plane location. J Magn Reson Imaging. 2004; 20(2):300-305. (Pubitemid 38970940)
    • (2004) Journal of Magnetic Resonance Imaging , vol.20 , Issue.2 , pp. 300-305
    • Shibanuma, N.1    Sheehan, F.T.2    Lipsky, P.E.3    Stanhope, S.J.4
  • 11
    • 18144416232 scopus 로고    scopus 로고
    • Limb positioning is critical for defining patellofemoral alignment and femoral shape
    • DOI 10.1097/01.blo.0000155078.52475.63
    • Shibanuma N, Sheehan FT, Stanhope SJ. Limb positioning is critical for defining patellofemoral alignment and femoral shape. Clin Orthop Relat Res. 2005; (434):198-206. (Pubitemid 40617517)
    • (2005) Clinical Orthopaedics and Related Research , Issue.434 , pp. 198-206
    • Shibanuma, N.1    Sheehan, F.T.2    Stanhope, S.J.3
  • 12
    • 27744556692 scopus 로고    scopus 로고
    • Results with navigated bicontact total hip arthroplasty
    • Lazovic D, Kaib N. Results with navigated bicontact total hip arthroplasty. Orthopedics. 2005; 28(10 suppl):s1227-1233. (Pubitemid 41582090)
    • (2005) Orthopedics , vol.28 , Issue.10 SUPPL.
    • Lazovic, D.1    Kaib, N.2
  • 13
    • 27744556693 scopus 로고    scopus 로고
    • OrthoPilot total hip arthroplasty workflow and surgery
    • Kiefer H, Othman A. OrthoPilot total hip arthroplasty workflow and surgery. Orthopedics. 2005; 28(10 suppl):s1221-1226. (Pubitemid 41582089)
    • (2005) Orthopedics , vol.28 , Issue.10 SUPPL.
    • Kiefer, H.1    Othman, A.2
  • 14
    • 0038686676 scopus 로고    scopus 로고
    • OrthoPilot cup navigation-how to optimise cup positioning?
    • Kiefer H. OrthoPilot cup navigation-how to optimise cup positioning? Int Orthop. 2003; 27(suppl 1):37-42.
    • (2003) Int Orthop , vol.27 , Issue.SUPPL. 1 , pp. 37-42
    • Kiefer, H.1
  • 15
    • 34249878470 scopus 로고    scopus 로고
    • Image-free cup navigation inaccuracy: A two-study approach
    • DOI 10.1080/10929080701374265, PII 779128864, caos-international special issue
    • Blendea S, Troccaz J, Ravey JN, Merloz P. Image-free cup navigation inaccuracy: a two-study approach. Comput Aided Surg. 2007; 12(3):176-180. (Pubitemid 46868265)
    • (2007) Computer Aided Surgery , vol.12 , Issue.3 , pp. 176-180
    • Blendea, S.1    Troccaz, J.2    Ravey, J.-N.3    Merloz, P.4
  • 16
    • 33847689072 scopus 로고    scopus 로고
    • Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty: A prospective, randomized, controlled study
    • DOI 10.2106/JBJS.F.00529
    • Parratte S, Argenson JN. Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study. J Bone Joint Surg Am. 2007; 89(3):494-499. (Pubitemid 46365349)
    • (2007) Journal of Bone and Joint Surgery - Series a , vol.89 , Issue.3 , pp. 494-499
    • Parratte, S.1    Argenson, J.-N.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.