메뉴 건너뛰기




Volumn 153, Issue 1, 2009, Pages 1-11

Computational Modeling of Microarterial Anastomoses With Size Discrepancy (Small-to-Large)

Author keywords

arterial size mismatch; computational fluid dynamics; end to end anastomosis; hemodynamics; microsurgery

Indexed keywords

ANIMAL EXPERIMENT; ARTERY ANASTOMOSIS; ARTERY BLOOD FLOW; ARTERY DIAMETER; ARTICLE; CONTROLLED STUDY; END TO END ANASTOMOSIS; FEMORAL ANGIOGRAPHY; MALE; MATHEMATICAL COMPUTING; NONHUMAN; PRIORITY JOURNAL; RAT; SHEAR STRESS;

EID: 63649108402     PISSN: 00224804     EISSN: 10958673     Source Type: Journal    
DOI: 10.1016/j.jss.2008.02.038     Document Type: Article
Times cited : (29)

References (26)
  • 2
    • 4243211893 scopus 로고
    • Experimental microvascular autografts
    • Serafin D., and Buncke H.J. (Eds), CV Mosby, St. Louis
    • Büchler U., and Buncke H.J. Experimental microvascular autografts. In: Serafin D., and Buncke H.J. (Eds). Microsurgical composite tissue transplantation (1979), CV Mosby, St. Louis 83-89
    • (1979) Microsurgical composite tissue transplantation , pp. 83-89
    • Büchler, U.1    Buncke, H.J.2
  • 3
    • 0018630021 scopus 로고
    • Preferential use of end-to-side arterial anastomoses in free flap transfers
    • Godina M. Preferential use of end-to-side arterial anastomoses in free flap transfers. Plast Reconstr Surg 64 (1979) 673
    • (1979) Plast Reconstr Surg , vol.64 , pp. 673
    • Godina, M.1
  • 4
    • 0000279062 scopus 로고
    • La technique opératoire des anastomoses vasculaires et la transplantation des viscères
    • Carrel A. La technique opératoire des anastomoses vasculaires et la transplantation des viscères. Lyon Med 98 (1902) 859
    • (1902) Lyon Med , vol.98 , pp. 859
    • Carrel, A.1
  • 5
    • 0018080555 scopus 로고
    • A new technique for end-to-end anastomosis of small vessels of different diameters
    • Watanabe K., and Makino K. A new technique for end-to-end anastomosis of small vessels of different diameters. Plast Reconstr Surg 62 (1978) 713
    • (1978) Plast Reconstr Surg , vol.62 , pp. 713
    • Watanabe, K.1    Makino, K.2
  • 6
    • 0027674823 scopus 로고
    • A new technique to anastomose vessels with great discrepancy in diameter
    • Xiu Z.F., and Song Y.G. A new technique to anastomose vessels with great discrepancy in diameter. Br J Plast Surg 46 (1993) 619
    • (1993) Br J Plast Surg , vol.46 , pp. 619
    • Xiu, Z.F.1    Song, Y.G.2
  • 7
    • 0033866127 scopus 로고    scopus 로고
    • Experimental microvascular sleeve anastomosis in size discrepancy vessels
    • de la Peña-Salcedo J.A., Cuesy C., and Lopez-Monjardin H. Experimental microvascular sleeve anastomosis in size discrepancy vessels. Microsurgery 20 (2000) 173
    • (2000) Microsurgery , vol.20 , pp. 173
    • de la Peña-Salcedo, J.A.1    Cuesy, C.2    Lopez-Monjardin, H.3
  • 8
    • 49749209981 scopus 로고
    • Intra-abdominal arterial anastomoses; an experimental study
    • Hurwitt E.S., Altman S., Borow M., et al. Intra-abdominal arterial anastomoses; an experimental study. Surgery 34 (1953) 1043
    • (1953) Surgery , vol.34 , pp. 1043
    • Hurwitt, E.S.1    Altman, S.2    Borow, M.3
  • 9
    • 0018828862 scopus 로고
    • Expansion of smaller vessel diameter by fish-mouth incision in microvascular anastomosis with marked size discrepancy
    • Harashina T., and Irigaray A. Expansion of smaller vessel diameter by fish-mouth incision in microvascular anastomosis with marked size discrepancy. Plast Reconstr Surg 65 (1980) 502
    • (1980) Plast Reconstr Surg , vol.65 , pp. 502
    • Harashina, T.1    Irigaray, A.2
  • 10
    • 0016029535 scopus 로고
    • The end-to-end anastomosis of blood vessels of different diameters
    • Brener B.J., Raines J.K., and Darling R.C. The end-to-end anastomosis of blood vessels of different diameters. Surg Gynecol Obstet 138 (1974) 249
    • (1974) Surg Gynecol Obstet , vol.138 , pp. 249
    • Brener, B.J.1    Raines, J.K.2    Darling, R.C.3
  • 11
    • 0021067984 scopus 로고
    • A new anastomosis technique for large-calibered vein grafts
    • Harashina T., and Takaki J.L. A new anastomosis technique for large-calibered vein grafts. Microsurgery 4 (1983) 171
    • (1983) Microsurgery , vol.4 , pp. 171
    • Harashina, T.1    Takaki, J.L.2
  • 12
    • 0028268703 scopus 로고
    • Microarterial anastomosis with a distal tapering technique
    • Ueda K., Harashina T., Inoue T., et al. Microarterial anastomosis with a distal tapering technique. J Reconstr Microsurg 10 (1994) 87
    • (1994) J Reconstr Microsurg , vol.10 , pp. 87
    • Ueda, K.1    Harashina, T.2    Inoue, T.3
  • 13
    • 0018400212 scopus 로고
    • Aggregation of human platelets in an annular vortex distal to a tubular expansion
    • Karino T., and Goldsmith H.L. Aggregation of human platelets in an annular vortex distal to a tubular expansion. Microvasc Res 17 (1979) 217
    • (1979) Microvasc Res , vol.17 , pp. 217
    • Karino, T.1    Goldsmith, H.L.2
  • 14
    • 0018779113 scopus 로고
    • Adhesion of human platelets to collagen on the walls distal to a tubular expansion
    • Karino T., and Goldsmith H.L. Adhesion of human platelets to collagen on the walls distal to a tubular expansion. Microvasc Res 17 (1979) 238
    • (1979) Microvasc Res , vol.17 , pp. 238
    • Karino, T.1    Goldsmith, H.L.2
  • 15
    • 0022587290 scopus 로고
    • Reductions in arterial diameter produced by chronic decreases in blood flow are endothelium-dependent
    • Langille B.L., and O'Donnell F. Reductions in arterial diameter produced by chronic decreases in blood flow are endothelium-dependent. Science 231 (1986) 405
    • (1986) Science , vol.231 , pp. 405
    • Langille, B.L.1    O'Donnell, F.2
  • 16
    • 0002424159 scopus 로고
    • Adaptive regulation of wall shear stress to flow change in the canine carotid artery
    • Kamiya A., and Togawa T. Adaptive regulation of wall shear stress to flow change in the canine carotid artery. Am J Physiol 239 (1980) H14
    • (1980) Am J Physiol , vol.239
    • Kamiya, A.1    Togawa, T.2
  • 17
    • 0021366787 scopus 로고
    • The vascular territories of the superior epigastric and the deep inferior epigastric systems
    • Boyd J.B., Taylor G.I., and Corlett R. The vascular territories of the superior epigastric and the deep inferior epigastric systems. Plast Reconstr Surg 73 (1984) 1
    • (1984) Plast Reconstr Surg , vol.73 , pp. 1
    • Boyd, J.B.1    Taylor, G.I.2    Corlett, R.3
  • 18
    • 1642307927 scopus 로고    scopus 로고
    • Algorithm in choosing recipient vessels for perforator free flap in breast reconstruction: The role of the internal mammary perforators
    • Hamdi M., Blondeel P., Van Landuyt K., et al. Algorithm in choosing recipient vessels for perforator free flap in breast reconstruction: The role of the internal mammary perforators. Br J Plast Surg 57 (2004) 258
    • (2004) Br J Plast Surg , vol.57 , pp. 258
    • Hamdi, M.1    Blondeel, P.2    Van Landuyt, K.3
  • 20
    • 63649121527 scopus 로고    scopus 로고
    • An Introduction to Computational Fluid Dynamics
    • Pearson Education Limited, Harlow
    • Versteeg H., and Malalasekera W. An Introduction to Computational Fluid Dynamics. The Finite Volume Method (2007), Pearson Education Limited, Harlow
    • (2007) The Finite Volume Method
    • Versteeg, H.1    Malalasekera, W.2
  • 21
  • 22
    • 34249816817 scopus 로고    scopus 로고
    • Flow patterns and preferred sites of intimal thickening in diameter-mismatched vein graft interpositions
    • Sunamura M., Ishibashi H., and Karino T. Flow patterns and preferred sites of intimal thickening in diameter-mismatched vein graft interpositions. Surgery 141 (2007) 764
    • (2007) Surgery , vol.141 , pp. 764
    • Sunamura, M.1    Ishibashi, H.2    Karino, T.3
  • 23
    • 33646569459 scopus 로고    scopus 로고
    • Haemodynamic enhancement in perforator flaps: The inversion phenomenon and its clinical significance. A study of the relation of blood velocity and flow between pedicle and perforator vessels in perforator flaps
    • Rubino C., Coscia V., Cavazzuti A.M., et al. Haemodynamic enhancement in perforator flaps: The inversion phenomenon and its clinical significance. A study of the relation of blood velocity and flow between pedicle and perforator vessels in perforator flaps. J Plast Reconstr Aesthet Surg 59 (2006) 636
    • (2006) J Plast Reconstr Aesthet Surg , vol.59 , pp. 636
    • Rubino, C.1    Coscia, V.2    Cavazzuti, A.M.3
  • 24
    • 0027431834 scopus 로고
    • Analysis of shear stress and hemodynamic factors in a model of coronary artery stenosis and thrombosis
    • Strony J., Beaudoin A., Brands D., et al. Analysis of shear stress and hemodynamic factors in a model of coronary artery stenosis and thrombosis. Am J Physiol 265 (1993) H1787
    • (1993) Am J Physiol , vol.265
    • Strony, J.1    Beaudoin, A.2    Brands, D.3
  • 25
    • 0030087637 scopus 로고    scopus 로고
    • Influence of non-Newtonian behavior of blood on flow in an elastic artery model
    • Dutta A., and Tarbell J.M. Influence of non-Newtonian behavior of blood on flow in an elastic artery model. J Biomech Eng 118 (1996) 111
    • (1996) J Biomech Eng , vol.118 , pp. 111
    • Dutta, A.1    Tarbell, J.M.2
  • 26
    • 33745864356 scopus 로고    scopus 로고
    • Non-Newtonian effects of blood flow on hemodynamics in distal vascular graft anastomoses
    • Chen J., Lu X.Y., and Wang W. Non-Newtonian effects of blood flow on hemodynamics in distal vascular graft anastomoses. J Biomech 39 (2006) 1983
    • (2006) J Biomech , vol.39 , pp. 1983
    • Chen, J.1    Lu, X.Y.2    Wang, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.