메뉴 건너뛰기




Volumn 82, Issue 2, 2009, Pages 162-165

Decrease of renal function due to warm ischemia after laparoscopic partial nephrectomy: Evaluation using 99mTc-DMSA renal scintigraphy

Author keywords

Partial nephrectomy; Renal tumor; Technetium 99m dimercaptosuccinic acid; Warm ischemic time

Indexed keywords

SUCCIMER TC 99M;

EID: 63449113424     PISSN: 00421138     EISSN: None     Source Type: Journal    
DOI: 10.1159/000200792     Document Type: Article
Times cited : (13)

References (12)
  • 4
    • 14144249580 scopus 로고    scopus 로고
    • The impact of warm ischaemia on renal function after laparoscopic partial nephrectomy
    • Desai MM, Gill IS, Ramani AP, Spaliviero M, Rybicki L, Kaouk JH: The impact of warm ischaemia on renal function after laparoscopic partial nephrectomy. BJU Int 2005; 95: 377-383.
    • (2005) BJU Int , vol.95 , pp. 377-383
    • Desai, M.M.1    Gill, I.S.2    Ramani, A.P.3    Spaliviero, M.4    Rybicki, L.5    Kaouk, J.H.6
  • 6
    • 0021066394 scopus 로고
    • Renal hypothermia: In vivo and ex-vivo
    • Novick AC: Renal hypothermia: In vivo and ex-vivo. Urol Clin North Am 1993; 10: 637-644.
    • (1993) Urol Clin North Am , vol.10 , pp. 637-644
    • Novick, A.C.1
  • 9
    • 0020196128 scopus 로고
    • Quantitation of renal function with static imaging agents
    • Taylor A Jr: Quantitation of renal function with static imaging agents. Semin Nucl Med 1982; 12: 330-344.
    • (1982) Semin Nucl Med , vol.12 , pp. 330-344
    • Taylor Jr, A.1
  • 10
    • 0030867411 scopus 로고    scopus 로고
    • Quantitative SPECT of DMSA uptake by the kidneys: Assessment of reproducibility
    • Groshar D, Moskovitz B, Issaq E, Nativ O: Quantitative SPECT of DMSA uptake by the kidneys: assessment of reproducibility. Kidney Int 1997; 52: 817-820.
    • (1997) Kidney Int , vol.52 , pp. 817-820
    • Groshar, D.1    Moskovitz, B.2    Issaq, E.3    Nativ, O.4
  • 12
    • 33947226107 scopus 로고    scopus 로고
    • Monitoring renal function: A prospective study comparing camera-based technetium-99m mercaptoacetyltriglycine clearance and creatinine clearance
    • Halkar R, Taylor A, Manatunga A, Issa MM, Myrick SE, Grant S, Shenvi NV: Monitoring renal function: a prospective study comparing camera-based technetium-99m mercaptoacetyltriglycine clearance and creatinine clearance. Urology 2007; 69: 426-430.
    • (2007) Urology , vol.69 , pp. 426-430
    • Halkar, R.1    Taylor, A.2    Manatunga, A.3    Issa, M.M.4    Myrick, S.E.5    Grant, S.6    Shenvi, N.V.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.