메뉴 건너뛰기




Volumn 24, Issue 5, 2004, Pages 810-812

Unsealed sclerotomy after intravitreal injection with a 30-gauge needle

Author keywords

30 gauge incision; Intravitreal injection; Unsealed sclerotomy; Vitreous incarceration

Indexed keywords

TISSUE PLASMINOGEN ACTIVATOR;

EID: 6344276560     PISSN: 0275004X     EISSN: None     Source Type: Journal    
DOI: 10.1097/00006982-200410000-00025     Document Type: Article
Times cited : (17)

References (6)
  • 1
    • 0034787109 scopus 로고    scopus 로고
    • Ultrasound biomicroscopy of sclerotomy sites: The effect of vitreous shaving around sclerotomy sites during pars plana vitrectomy
    • Sabti K, Kapusta M, Mansour M, et al. Ultrasound biomicroscopy of sclerotomy sites: the effect of vitreous shaving around sclerotomy sites during pars plana vitrectomy. Retina 2001; 21:464-468.
    • (2001) Retina , vol.21 , pp. 464-468
    • Sabti, K.1    Kapusta, M.2    Mansour, M.3
  • 2
    • 0027739646 scopus 로고
    • Wound complications in pars plana vitrectomy
    • Kreiger AE. Wound complications in pars plana vitrectomy. Retina 1993;13:335-344.
    • (1993) Retina , vol.13 , pp. 335-344
    • Kreiger, A.E.1
  • 3
    • 0034534318 scopus 로고    scopus 로고
    • Quantitative effect of intravitreally injected tissue plasminogen activator and gas on subretinal hemorrhage
    • Hesse L, Schroeder B, Heller G, Kroll P. Quantitative effect of intravitreally injected tissue plasminogen activator and gas on subretinal hemorrhage. Retina 2000;20:500-505.
    • (2000) Retina , vol.20 , pp. 500-505
    • Hesse, L.1    Schroeder, B.2    Heller, G.3    Kroll, P.4
  • 4
    • 0032727771 scopus 로고    scopus 로고
    • Self-sealing, sutureless sclerotomy in pars-plana vitrectomy
    • Schmidt J, Nietgen GW, Brieden S. Self-sealing, sutureless sclerotomy in pars-plana vitrectomy. Klin Monatsbl Augenheilkd 1999;215:247-251.
    • (1999) Klin Monatsbl Augenheilkd , vol.215 , pp. 247-251
    • Schmidt, J.1    Nietgen, G.W.2    Brieden, S.3
  • 5
    • 0034080531 scopus 로고    scopus 로고
    • External diaphanoscopic illuminator: A new device for visualization in pars plana vitrectomy
    • Schmidt JC, Nietgen GW, Hesse L, Kroll P. External diaphanoscopic illuminator: a new device for visualization in pars plana vitrectomy. Retina 2000;20:103-106.
    • (2000) Retina , vol.20 , pp. 103-106
    • Schmidt, J.C.1    Nietgen, G.W.2    Hesse, L.3    Kroll, P.4
  • 6
    • 0036788635 scopus 로고    scopus 로고
    • Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery
    • Fujii GY, de Juan E Jr, Humayun MS, et al. Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery. Ophthalmology 2002;109:1814-1820.
    • (2002) Ophthalmology , vol.109 , pp. 1814-1820
    • Fujii, G.Y.1    De Juan Jr., E.2    Humayun, M.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.