메뉴 건너뛰기




Volumn 82, Issue 5, 2004, Pages 531-534

Position of anterior capsulorhexis and posterior capsule opacification

Author keywords

AcrySof; Capsulorhexis; Posterior capsule opacification; Round edge; Sharp edge; Silicone intraocular lens

Indexed keywords

SILICONE;

EID: 6344265473     PISSN: 13953907     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1600-0420.2004.00322.x     Document Type: Article
Times cited : (42)

References (17)
  • 2
    • 0031668605 scopus 로고    scopus 로고
    • Lens epithelial cell regression on the posterior capsule with different intraocular flens materials
    • Hollick EJ, Spalton DJ, Ursell PG & Pande MV (1998): Lens epithelial cell regression on the posterior capsule with different intraocular flens materials. Br J Ophthalmol 82: 1182-1188.
    • (1998) Br. J. Ophthalmol. , vol.82 , pp. 1182-1188
    • Hollick, E.J.1    Spalton, D.J.2    Ursell, P.G.3    Pande, M.V.4
  • 3
    • 0032622426 scopus 로고    scopus 로고
    • The effect of polymethylmethacrylate, silicone and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery
    • Hollick EJ, Spalton DJ, Ursell PG, Pande MV, Barman SA, Boyce JF & Tilling K (1999): The effect of polymethylmethacrylate, silicone and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery. Ophthalmology 106: 49-54.
    • (1999) Ophthalmology , vol.106 , pp. 49-54
    • Hollick, E.J.1    Spalton, D.J.2    Ursell, P.G.3    Pande, M.V.4    Barman, S.A.5    Boyce, J.F.6    Tilling, K.7
  • 5
    • 0032789967 scopus 로고    scopus 로고
    • Cell biology of posterior capsular opacification
    • Marcantonio JM & Vrensen GF (1999): Cell biology of posterior capsular opacification. Eye 13: 484-488.
    • (1999) Eye , vol.13 , pp. 484-488
    • Marcantonio, J.M.1    Vrensen, G.F.2
  • 6
    • 0034926360 scopus 로고    scopus 로고
    • The effect of polymethylmethacrylate and AcrySof intraocular lenses on the posterior capsule in patients with a large capsulorhexis
    • Meacock WR, Spalton DJ, Hollick EJ, Barman S & Boyce JF (2001): The effect of polymethylmethacrylate and AcrySof intraocular lenses on the posterior capsule in patients with a large capsulorhexis. Jpn J Ophthalmol 45: 348-354.
    • (2001) Jpn. J. Ophthalmol. , vol.45 , pp. 348-354
    • Meacock, W.R.1    Spalton, D.J.2    Hollick, E.J.3    Barman, S.4    Boyce, J.F.5
  • 7
    • 0035319373 scopus 로고    scopus 로고
    • Effect of round-edged acrylic intraocular lenses on preventing posterior capsule opacification
    • Nishi O, Nishi K, Akura J & Nagata T (2001): Effect of round-edged acrylic intraocular lenses on preventing posterior capsule opacification. J Cataract Refract Surg 27: 608-613.
    • (2001) J. Cataract Refract. Surg. , vol.27 , pp. 608-613
    • Nishi, O.1    Nishi, K.2    Akura, J.3    Nagata, T.4
  • 8
    • 0031817140 scopus 로고    scopus 로고
    • Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens
    • Nishi O, Nishi K & Sakanishi K (1998): Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens. Ophthalmic Surg Lasers 29: 587-594.
    • (1998) Ophthalmic Surg. Lasers , vol.29 , pp. 587-594
    • Nishi, O.1    Nishi, K.2    Sakanishi, K.3
  • 9
    • 0033772907 scopus 로고    scopus 로고
    • Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges
    • Nishi O, Nishi K & Wickstrom K (2000): Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges. J Cataract Refract Surg 26: 1543-1549.
    • (2000) J. Cataract Refract. Surg. , vol.26 , pp. 1543-1549
    • Nishi, O.1    Nishi, K.2    Wickstrom, K.3
  • 10
    • 0033968119 scopus 로고    scopus 로고
    • Surgical prevention of posterior capsule opacification. Part 3. Intraocular lens optic barrier effect as a second line of defence
    • Peng Q, Visessook N & Apple DJ et al. (2000): Surgical prevention of posterior capsule opacification. Part 3. Intraocular lens optic barrier effect as a second line of defence. J Cataract Refract Surg 26: 198-213.
    • (2000) J. Cataract Refract. Surg. , vol.26 , pp. 198-213
    • Peng, Q.1    Visessook, N.2    Apple, D.J.3
  • 11
    • 0033497365 scopus 로고    scopus 로고
    • Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part 2. Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification
    • Ram J, Apple DJ, Peng Q, Visessook N, Auffarth GU, Schoderbek RJ & Ready EL (1999): Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part 2. Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification. Ophthalmology 106: 891-900.
    • (1999) Ophthalmology , vol.106 , pp. 891-900
    • Ram, J.1    Apple, D.J.2    Peng, Q.3    Visessook, N.4    Auffarth, G.U.5    Schoderbek, R.J.6    Ready, E.L.7
  • 12
    • 0034858143 scopus 로고    scopus 로고
    • Neodymium: YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone and acrylic intraocular lenses
    • Ram J, Kaushik S, Brar GS & Gupta A (2001): Neodymium: YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone and acrylic intraocular lenses. Ophthalmic Surg Lasers 32: 375-382.
    • (2001) Ophthalmic Surg. Lasers , vol.32 , pp. 375-382
    • Ram, J.1    Kaushik, S.2    Brar, G.S.3    Gupta, A.4
  • 16
    • 0041355232 scopus 로고    scopus 로고
    • Posterior capsule opacification: Comparison of three intraocular lenses of different materials and design
    • Wejde G, Kugelberg M & Zetterstrom C (2003): Posterior capsule opacification: comparison of three intraocular lenses of different materials and design. J Cataract Refract Surg 29: 1556-1559.
    • (2003) J. Cataract Refract. Surg. , vol.29 , pp. 1556-1559
    • Wejde, G.1    Kugelberg, M.2    Zetterstrom, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.