메뉴 건너뛰기




Volumn 14, Issue 3, 2004, Pages 139-145

List-mode EM algorithms for limited precision high-resolution PET image reconstruction

Author keywords

Image reconstruction; List mode; PET

Indexed keywords

ALGORITHMS; COMPUTATIONAL METHODS; DATA REDUCTION; IMAGING TECHNIQUES; MATRIX ALGEBRA; POSITRON EMISSION TOMOGRAPHY; VECTORS;

EID: 6344219586     PISSN: 08999457     EISSN: None     Source Type: Journal    
DOI: 10.1002/ima.20017     Document Type: Article
Times cited : (12)

References (21)
  • 2
    • 11944252390 scopus 로고    scopus 로고
    • Design of a motion-compensation OSEM list-mode algorithm for resolution recovery reconstruction for the HRRT
    • Portland, Oregon
    • R.E. Carson, W.C, Barker, J.-S. Liow, S. Adler, and C.A, Johnson, Design of a motion-compensation OSEM list-mode algorithm for resolution recovery reconstruction for the HRRT. Presented at IEEE Nuclear Science Symposium, Portland, Oregon, 2003, M16-6.
    • (2003) IEEE Nuclear Science Symposium
    • Carson, R.E.1    Barker, W.C.2    Liow, J.-S.3    Adler, S.4    Johnson, C.A.5
  • 6
    • 0036035411 scopus 로고    scopus 로고
    • A provably convergent OS-EM like reconstruction algorithm for emission tomography
    • I.-T. Hsiao, A. Rangarajan, and O. Gindi, A provably convergent OS-EM like reconstruction algorithm for emission tomography, SPIE Med Imaging 4684 (2002), 10-19.
    • (2002) SPIE Med Imaging , vol.4684 , pp. 10-19
    • Hsiao, I.-T.1    Rangarajan, A.2    Gindi, O.3
  • 7
    • 0033335619 scopus 로고    scopus 로고
    • A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals
    • A.P. Jeavons, R.A. Chandler, and C.A.R. Dettmar, A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals, IEEE Trans Nucl Sci 46 (1999), 468-473.
    • (1999) IEEE Trans Nucl Sci , vol.46 , pp. 468-473
    • Jeavons, A.P.1    Chandler, R.A.2    Dettmar, C.A.R.3
  • 8
    • 11944252072 scopus 로고    scopus 로고
    • A globally convergent regularized ordered-subset algorithm for list-mode reconstruction
    • Portland, Oregon
    • P.K. Khurd and G.R. Gindi, A globally convergent regularized ordered-subset algorithm for list-mode reconstruction. Presented at IEEE Nuclear Science Symposium and Medical Imaging, Portland, Oregon, 2003, M14-195.
    • (2003) IEEE Nuclear Science Symposium and Medical Imaging
    • Khurd, P.K.1    Gindi, G.R.2
  • 9
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • K.-Lange, and R.-Carson, EM reconstruction algorithms for emission and transmission tomography, J Comput Assist Tomogr 8 (1984), 306-316.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 10
    • 0035384871 scopus 로고    scopus 로고
    • The design and implementation of COSEM, an iterative algorithm for fully 3-D listmode data
    • R. Levkovitz, D. Falikman, M. Zibulevsky, A. Ben-Tal, and A. Nemirovski. The design and implementation of COSEM, an iterative algorithm for fully 3-D listmode data, IEEE Trans Med Imag 20 (2001), 633-642.
    • (2001) IEEE Trans Med Imag , vol.20 , pp. 633-642
    • Levkovitz, R.1    Falikman, D.2    Zibulevsky, M.3    Ben-Tal, A.4    Nemirovski, A.5
  • 12
    • 0032034223 scopus 로고    scopus 로고
    • List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET
    • L. Parra and H.H. Barrett, List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET, IEEE Trans Med. Imag 17 (1998), 228-235.
    • (1998) IEEE Trans Med. Imag , vol.17 , pp. 228-235
    • Parra, L.1    Barrett, H.H.2
  • 14
    • 6344255837 scopus 로고    scopus 로고
    • Weighted iterative list-mode reconstruction with random correction for the high resolution research tomogragh
    • submitted
    • A. Rahmim, M. Lenox, A.J. Reader, C. Michel, Z. Burbar, T.J. Ruth, and V. Sossi, Weighted iterative list-mode reconstruction with random correction for the high resolution research tomogragh. Phys Med Biol, submitted.
    • Phys Med Biol
    • Rahmim, A.1    Lenox, M.2    Reader, A.J.3    Michel, C.4    Burbar, Z.5    Ruth, T.J.6    Sossi, V.7
  • 15
    • 3342994816 scopus 로고    scopus 로고
    • Convergence proofs for the COSEM-ML and COSEM-MAP algorithms
    • Medical Image Processing Lab, Departments of Radiology and Electrical Engineering, State University of New York at Stony Brook
    • A. Rangarajan, P. Khurd, I.-T. Hsiao, and G. Gindi, Convergence proofs for the COSEM-ML and COSEM-MAP algorithms, Tech Rep MIPL-03-1, Medical Image Processing Lab, Departments of Radiology and Electrical Engineering, State University of New York at Stony Brook, 2003.
    • (2003) Tech Rep MIPL-03-1 , vol.MIPL-03-1
    • Rangarajan, A.1    Khurd, P.2    Hsiao, I.-T.3    Gindi, G.4
  • 17
    • 0031972028 scopus 로고    scopus 로고
    • Fast accurate iterative reconstruction for low-statistics positron volume imaging
    • A.J. Reader, K. Erlandsson, M.A. Flower, and R.J. Ott, Fast accurate iterative reconstruction for low-statistics positron volume imaging, Physi Med Biol 43 (1998), 835-846.
    • (1998) Physi Med Biol , vol.43 , pp. 835-846
    • Reader, A.J.1    Erlandsson, K.2    Flower, M.A.3    Ott, R.J.4
  • 19
    • 0035577569 scopus 로고    scopus 로고
    • Developments in whole body molecular imaging of live subjects
    • A J. Reader and J. Zweit, Developments in whole body molecular imaging of live subjects. Trends Pharmacol Sci 22:(2001), 604-607.
    • (2001) Trends Pharmacol Sci , vol.22 , pp. 604-607
    • Reader, A.J.1    Zweit, J.2
  • 20
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L.A. Shepp and Y. Vardi, Maximum likelihood reconstruction for emission tomography, IEEE Trans Med Imag 1 (1982), 113-122.
    • (1982) IEEE Trans Med Imag , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.