메뉴 건너뛰기




Volumn 14, Issue 1, 2009, Pages 45-47

Comparison of two automated sphygmomanometers for use in the office setting

Author keywords

Automated sphygmomanometers; Blood pressure measurement; Hypertension diagnosis

Indexed keywords

ADULT; ARTICLE; AUTOANALYSIS; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; CONTROLLED STUDY; DIASTOLIC BLOOD PRESSURE; FEMALE; HUMAN; HYPERTENSION; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SPHYGMOMANOMETER; SYSTOLIC BLOOD PRESSURE;

EID: 63149157452     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: 10.1097/MBP.0b013e32831e314f     Document Type: Article
Times cited : (39)

References (16)
  • 1
    • 20144375119 scopus 로고    scopus 로고
    • For the Canadian Hypertension Education Program: The 2005 Canadian hypertension Education Program (CHEP) recommendations for the management of hypertension. Part 1: blood pressure measurement, diagnosis and assessment of risk
    • Hemmelgarn BR, McAlister FA, Myers MG, McKay DW, Bolli P, Abbott C, et al. For the Canadian Hypertension Education Program: the 2005 Canadian hypertension Education Program (CHEP) recommendations for the management of hypertension. Part 1: blood pressure measurement, diagnosis and assessment of risk. Can J Cardiol 2005; 21:645-656.
    • (2005) Can J Cardiol , vol.21 , pp. 645-656
    • Hemmelgarn, B.R.1    McAlister, F.A.2    Myers, M.G.3    McKay, D.W.4    Bolli, P.5    Abbott, C.6
  • 2
    • 19944429836 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals Part 1: Blood pressure measurement in humans a statement for professionals from the subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research
    • mPickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al. Recommendations for blood pressure measurement in humans and experimental animals Part 1: blood pressure measurement in humans a statement for professionals from the subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension 2005; 45:142-161.
    • (2005) Hypertension , vol.45 , pp. 142-161
    • mPickering, T.G.1    Hall, J.E.2    Appel, L.J.3    Falkner, B.E.4    Graves, J.5    Hill, M.N.6
  • 3
    • 34250350040 scopus 로고    scopus 로고
    • 3Mancia G, De Backer G, Dominiczak A, Cifkova R, Fagard R, Germano G, et al. 2007 Guidelines for the Management of Arterial Hypertension: the task force for the management of arterial hypertension of the European society of hypertension and the European society of cardiology. J Hypertens 2007; 25:1105-1187.
    • 3Mancia G, De Backer G, Dominiczak A, Cifkova R, Fagard R, Germano G, et al. 2007 Guidelines for the Management of Arterial Hypertension: the task force for the management of arterial hypertension of the European society of hypertension and the European society of cardiology. J Hypertens 2007; 25:1105-1187.
  • 4
    • 15744392182 scopus 로고    scopus 로고
    • Ambulatory blood pressure monitoring for routine clinical practice
    • Myers MG. Ambulatory blood pressure monitoring for routine clinical practice. Hypertension 2005; 5:483-484.
    • (2005) Hypertension , vol.5 , pp. 483-484
    • Myers, M.G.1
  • 6
    • 0034959116 scopus 로고    scopus 로고
    • Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults
    • 6
    • 6.White WG, Anwar YA. Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults. Blood Press Monit 2001; 6:107-110.
    • (2001) Blood Press Monit , vol.6 , pp. 107-110
    • White, W.G.1    Anwar, Y.A.2
  • 7
    • 0037528711 scopus 로고    scopus 로고
    • Use of an automated blood pressure recording device, the BpTRU, to reduce the 'white coat effect' in routine practice
    • Myers MG, Valdivieso MA. Use of an automated blood pressure recording device, the BpTRU, to reduce the 'white coat effect' in routine practice. Am J Hypertens 2003; 16:494-497.
    • (2003) Am J Hypertens , vol.16 , pp. 494-497
    • Myers, M.G.1    Valdivieso, M.A.2
  • 8
    • 26844562540 scopus 로고    scopus 로고
    • The BpTRU automatic blood pressure monitor compared to 24-h ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension
    • Beckett L, Godwin M. The BpTRU automatic blood pressure monitor compared to 24-h ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension. BMC Cardiovasc Disord 2005; 5:18.
    • (2005) BMC Cardiovasc Disord , vol.5 , pp. 18
    • Beckett, L.1    Godwin, M.2
  • 9
    • 33745163278 scopus 로고    scopus 로고
    • Performance of the automated BpTRU measurement device in the assessment of white-coat hypertension and white-coat effect
    • Culleton BF, McKay DW, Campbell NR. Performance of the automated BpTRU measurement device in the assessment of white-coat hypertension and white-coat effect. Blood Press Monit 2006; 11:37-42.
    • (2006) Blood Press Monit , vol.11 , pp. 37-42
    • Culleton, B.F.1    McKay, D.W.2    Campbell, N.R.3
  • 10
    • 33744510715 scopus 로고    scopus 로고
    • Automated blood pressure measurement in routine clinical practice
    • Myers MG. Automated blood pressure measurement in routine clinical practice. Stood Press Monit 2006; 11:59-62.
    • (2006) Stood Press Monit , vol.11 , pp. 59-62
    • Myers, M.G.1
  • 12
    • 34548433551 scopus 로고    scopus 로고
    • Validation of the Omron M5-1, R5-1 and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension
    • Omboni S, Riva I, Giglio A, Caldara G, Groppelli A, Parati G. Validation of the Omron M5-1, R5-1 and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension. Stood Press Monit 2007; 12:233-242.
    • (2007) Stood Press Monit , vol.12 , pp. 233-242
    • Omboni, S.1    Riva, I.2    Giglio, A.3    Caldara, G.4    Groppelli, A.5    Parati, G.6
  • 13
    • 57149138712 scopus 로고    scopus 로고
    • Optimum frequency of blood pressure measured using an automated sphygmomanometer
    • Myers MG, Valdivieso M, Kiss A. Optimum frequency of blood pressure measured using an automated sphygmomanometer. Blood Press Monit 2008; 13:333-338.
    • (2008) Blood Press Monit , vol.13 , pp. 333-338
    • Myers, M.G.1    Valdivieso, M.2    Kiss, A.3
  • 14
    • 0027218269 scopus 로고
    • Short report: An outline of the revised British Hypertension Society protocol for the evaluation of blood pressure measuring devices
    • O'Brien E, Petrie J, Littler W, de Swiet M, Padfield PL, Altman DG, et al. Short report: an outline of the revised British Hypertension Society protocol for the evaluation of blood pressure measuring devices. J Hypertens 1993; 11:677-679.
    • (1993) J Hypertens , vol.11 , pp. 677-679
    • O'Brien, E.1    Petrie, J.2    Littler, W.3    de Swiet, M.4    Padfield, P.L.5    Altman, D.G.6
  • 15
    • 0003473364 scopus 로고
    • Association for the Advancement of Medical Instrumentation:, AAMI, 3330 Washington Boulevard, Arlington, Virginia, USA
    • Association for the Advancement of Medical Instrumentation: American national standard: electronic or automated sphygmomanometers. AAMI, 3330 Washington Boulevard, Arlington, Virginia, USA, 22201. 1993.
    • (1993) American national standard: Electronic or automated sphygmomanometers , pp. 22201
  • 16
    • 0035992025 scopus 로고    scopus 로고
    • With the statistical assistance of Atkins N and Gerin W on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension: International protocol for validation of blood pressure measuring devices in adults
    • O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, et al. With the statistical assistance of Atkins N and Gerin W on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension: international protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7:3-17.
    • (2002) Blood Press Monit , vol.7 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3    Myers, M.4    Parati, G.5    Staessen, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.