Adult ICU ventilators to provide neonatal ventilation: A lung simulator study

Author keywords

Equipment safety; Intensive care units; Models; Neonatal; Respiration, artificial; Respiratory mechanics; Ventilators, mechanical

Indexed keywords

ARTICLE; ARTIFICIAL VENTILATION; INTENSIVE CARE UNIT; LUNG MECHANICS; SIMULATOR; TIDAL VOLUME; VENTILATOR;

EID: 62949225400     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-008-1332-0     Document Type: Article
Times cited : (31)

References (14)
  • 1
    • 62949091569 scopus 로고
    • 3 England Blackwell Scientific Publications Ltd Oxford
    • Mushin WW (1980) Automatic ventilation of the lungs, 3rd edn. England Blackwell Scientific Publications Ltd, Oxford
    • (1980)
    • Mushin, W.W.1
  • 5
    • 62949168447 scopus 로고
    • Understanding the IMVbird. From 876. Palm Springs Calif
    • Understanding the IMVbird. From 876 (1975) Bird Corp. Palm Springs, Calif
    • (1975)
  • 6
    • 62949112709 scopus 로고    scopus 로고
    • Triggering and initial gas delivery: The Babylog vs. ICU ventilators in the neo-mode (Abstract)
    • AD Marchese D Chipman P De La Oliva RM Kacmarek 2007 Triggering and initial gas delivery: the Babylog vs. ICU ventilators in the neo-mode (Abstract) Resp Care 52 1566
    • (2007) Resp Care , vol.52 , pp. 1566
    • Marchese, A.D.1    Chipman, D.2    De La Oliva, P.3    Kacmarek, R.M.4
  • 8
    • 19444386654 scopus 로고    scopus 로고
    • Effort and work of breathing in neonates during assisted, patient triggered ventilation
    • M Kapasi Y Fujino M Kirmse EA Catlin RM Kacmarek 2001 Effort and work of breathing in neonates during assisted, patient triggered ventilation Ped Crit Care 2 9 16
    • (2001) Ped Crit Care , vol.2 , pp. 9-16
    • Kapasi, M.1    Fujino, Y.2    Kirmse, M.3    Catlin, E.A.4    Kacmarek, R.M.5
  • 11
    • 0019595430 scopus 로고
    • Performance of neonatal ventilators; The effect of changes in resistance and compliance
    • G Simbruner GA Gregory 1981 Performance of neonatal ventilators; the effect of changes in resistance and compliance Crit Care Med 9 509 515
    • (1981) Crit Care Med , vol.9 , pp. 509-515
    • Simbruner, G.1    Gregory, G.A.2
  • 12
    • 33645280587 scopus 로고    scopus 로고
    • Lung Function tests in neonates and infants with chronic lung disease: Lung and chest-wall mechanics
    • M Gappa J Pillow J Allen O Mayer J Stocks 2006 Lung Function tests in neonates and infants with chronic lung disease: Lung and chest-wall mechanics Pediatr Pulmonol 41 291 317
    • (2006) Pediatr Pulmonol , vol.41 , pp. 291-317
    • Gappa, M.1    Pillow, J.2    Allen, J.3    Mayer, O.4    Stocks, J.5
  • 13
    • 0028824792 scopus 로고
    • Airway leak size in neonates and auto-cycling of three flow-triggered ventilators
    • G Berstein E Knodel H Gergory 1995 Airway leak size in neonates and auto-cycling of three flow-triggered ventilators Crit Care Med 23 1739 1744
    • (1995) Crit Care Med , vol.23 , pp. 1739-1744
    • Berstein, G.1    Knodel, E.2    Gergory, H.3
  • 14
    • 33847196138 scopus 로고    scopus 로고
    • Performance of neonatal ventilators in volume targeted ventilation mode
    • A Sharma AD Milner A Greenough 2007 Performance of neonatal ventilators in volume targeted ventilation mode Acta Paediatr 96 176 180
    • (2007) Acta Paediatr , vol.96 , pp. 176-180
    • Sharma, A.1    Milner, A.D.2    Greenough, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.