메뉴 건너뛰기




Volumn 64, Issue 3 SUPPL., 2009, Pages

Current technological advances of bipolar coagulation

Author keywords

Bipolar; Coagulation; Hemostasis

Indexed keywords

ARTICLE; ELECTROCOAGULATION; ELECTROSURGERY; HEAT INJURY; HEMOSTASIS; IATROGENIC DISEASE; PEROPERATIVE CARE; PRIORITY JOURNAL; SURGICAL INSTRUMENT;

EID: 62849094713     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1227/01.NEU.0000335644.57481.97     Document Type: Article
Times cited : (16)

References (47)
  • 1
    • 0024729965 scopus 로고
    • An introduction to electrosurgery units
    • Applegate S: An introduction to electrosurgery units. Biomed Instrum Technol 23:407-408, 1989.
    • (1989) Biomed Instrum Technol , vol.23 , pp. 407-408
    • Applegate, S.1
  • 2
    • 28244436472 scopus 로고    scopus 로고
    • Application of the Bipolar Forceps with Heat Pipe Technology (ISOCOOL) in Neurosurgery
    • Arakawa Y, Hashimoto N: Application of the Bipolar Forceps with Heat Pipe Technology (ISOCOOL) in Neurosurgery. Jpn J Neurosurg (Tokyo) 14:698-705, 2005.
    • (2005) Jpn J Neurosurg (Tokyo) , vol.14 , pp. 698-705
    • Arakawa, Y.1    Hashimoto, N.2
  • 3
    • 0030051080 scopus 로고    scopus 로고
    • Prevention of char adherence to bipolar diathermy forceps tips
    • Beatty RM: Prevention of char adherence to bipolar diathermy forceps tips. J Neurosurg 84:540, 1996.
    • (1996) J Neurosurg , vol.84 , pp. 540
    • Beatty, R.M.1
  • 4
    • 0026355520 scopus 로고
    • Studies on coagulation and the development of an automatic computerized bipolar coagulator. Technical note
    • Bergdahl B, Vällfors B: Studies on coagulation and the development of an automatic computerized bipolar coagulator. Technical note. J Neurosurg 75:148-151, 1991.
    • (1991) J Neurosurg , vol.75 , pp. 148-151
    • Bergdahl, B.1    Vällfors, B.2
  • 5
    • 0024363035 scopus 로고
    • The effect of electrode design on the efficiency of delivery of radiofrequency energy to cardiac tissue in vitro
    • Blouin LT, Marcus FI: The effect of electrode design on the efficiency of delivery of radiofrequency energy to cardiac tissue in vitro. Pacing Clin Electrophysiol 12:136-143, 1989.
    • (1989) Pacing Clin Electrophysiol , vol.12 , pp. 136-143
    • Blouin, L.T.1    Marcus, F.I.2
  • 8
    • 62849084399 scopus 로고    scopus 로고
    • Cushing H, Bovie WT: Electro-surgery as an aid to the removal of intracranial rumors. With a preliminary note on a new surgical- current generator by W. T. Bovie. Surg Gynecol Obstet 47:751-785, 1928.
    • Cushing H, Bovie WT: Electro-surgery as an aid to the removal of intracranial rumors. With a preliminary note on a new surgical- current generator by W. T. Bovie. Surg Gynecol Obstet 47:751-785, 1928.
  • 12
    • 0016826711 scopus 로고
    • Bipolar jeweler's forceps with automatic irrigation, for coagulation in microsurgery
    • Dujovny M, Vas R, Osgood CP: Bipolar jeweler's forceps with automatic irrigation, for coagulation in microsurgery. Plast Reconstr Surg 56:585-587, 1975.
    • (1975) Plast Reconstr Surg , vol.56 , pp. 585-587
    • Dujovny, M.1    Vas, R.2    Osgood, C.P.3
  • 15
    • 33646473414 scopus 로고    scopus 로고
    • Three-way bipolar forceps: A novel bipolar coagulator system for nerve stimulation and detection of nerve potentials
    • Fujita Y, Muragaki Y, Nambu K, Hori T, Iseki H: Three-way bipolar forceps: A novel bipolar coagulator system for nerve stimulation and detection of nerve potentials. Neurol Med Chir (Tokyo) 46:169-175, 2006.
    • (2006) Neurol Med Chir (Tokyo) , vol.46 , pp. 169-175
    • Fujita, Y.1    Muragaki, Y.2    Nambu, K.3    Hori, T.4    Iseki, H.5
  • 16
    • 0010537476 scopus 로고
    • Two point coagulation. A new principle and instrument for applying coagulation current in neurosurgery
    • Greenwood J Jr: Two point coagulation. A new principle and instrument for applying coagulation current in neurosurgery. Am J Surg 50:267-270, 1940.
    • (1940) Am J Surg , vol.50 , pp. 267-270
    • Greenwood Jr, J.1
  • 17
    • 0013767880 scopus 로고
    • Two point coagulation: A follow-up report of a new technic and instrument for electrocoagulation in neurosurgery
    • Greenwood J Jr: Two point coagulation: a follow-up report of a new technic and instrument for electrocoagulation in neurosurgery. Arch Phys Ther 23:552-554, 1942.
    • (1942) Arch Phys Ther , vol.23 , pp. 552-554
    • Greenwood Jr, J.1
  • 18
    • 0040564001 scopus 로고
    • Two-point or interpolar coagulation; review after a twelve-year period with notes on addition of a sucker tip
    • Greenwood J Jr: Two-point or interpolar coagulation; review after a twelve-year period with notes on addition of a sucker tip. J Neurosurg 12:196-197, 1955.
    • (1955) J Neurosurg , vol.12 , pp. 196-197
    • Greenwood Jr, J.1
  • 19
    • 0024332843 scopus 로고
    • Cytoprotective effect of isotonic mannitol at low oxygen tension
    • Gronow G, Prechel P, Klause N: Cytoprotective effect of isotonic mannitol at low oxygen tension. Adv Exp Med Biol 248:755-762, 1989.
    • (1989) Adv Exp Med Biol , vol.248 , pp. 755-762
    • Gronow, G.1    Prechel, P.2    Klause, N.3
  • 21
    • 0026550284 scopus 로고
    • Hyperthermic injury versus crush injury in the rat sciatic nerve: A comparative functional, histopathological and morphometrical study
    • Hoogeveen JF, Troost D, Wondergem J, van der Kracht AH, Haveman J: Hyperthermic injury versus crush injury in the rat sciatic nerve: A comparative functional, histopathological and morphometrical study. J Neurol Sci 108:55-64, 1992.
    • (1992) J Neurol Sci , vol.108 , pp. 55-64
    • Hoogeveen, J.F.1    Troost, D.2    Wondergem, J.3    van der Kracht, A.H.4    Haveman, J.5
  • 23
    • 0017236376 scopus 로고
    • Microvascular bipolar coagulator. Technical note
    • Jacques S, Bullara LA, Pudenz RH: Microvascular bipolar coagulator. Technical note. J Neurosurg 44:523-524, 1976.
    • (1976) J Neurosurg , vol.44 , pp. 523-524
    • Jacques, S.1    Bullara, L.A.2    Pudenz, R.H.3
  • 24
    • 0015384531 scopus 로고
    • Self-irrigating bipolar diathermy forceps. Technical note
    • King TT, Worpole R: Self-irrigating bipolar diathermy forceps. Technical note. J Neurosurg 37:246-247, 1972.
    • (1972) J Neurosurg , vol.37 , pp. 246-247
    • King, T.T.1    Worpole, R.2
  • 25
    • 0033379197 scopus 로고    scopus 로고
    • Comparison of a new automatically controlled electrocoagulator (Valleylab NS 2000-INSTANT RESPONSE technology) with a high-frequency coagulator
    • Lee JY, Ebel H, Balogh A, Lammers E, Klug N, Schröder R: Comparison of a new automatically controlled electrocoagulator (Valleylab NS 2000-INSTANT RESPONSE technology) with a high-frequency coagulator. Minim Invasive Neurosurg 42:212-215, 1999.
    • (1999) Minim Invasive Neurosurg , vol.42 , pp. 212-215
    • Lee, J.Y.1    Ebel, H.2    Balogh, A.3    Lammers, E.4    Klug, N.5    Schröder, R.6
  • 26
    • 0021268803 scopus 로고
    • The mechanism of mannitol in reducing ischemic injury: Hyperosmolarity or hydroxyl scavenger?
    • Magovern GJ Jr, Boiling SF, Casale AS, Bulkley BH, Gardner TJ: The mechanism of mannitol in reducing ischemic injury: Hyperosmolarity or hydroxyl scavenger? Circulation 70:191-195, 1984.
    • (1984) Circulation , vol.70 , pp. 191-195
    • Magovern Jr, G.J.1    Boiling, S.F.2    Casale, A.S.3    Bulkley, B.H.4    Gardner, T.J.5
  • 27
    • 0344830608 scopus 로고
    • New trends in microsurgery and applied technology
    • Pluchino F, Broggi G eds, Berlin, Springer-Verlag
    • Malis LI: New trends in microsurgery and applied technology, in Pluchino F, Broggi G (eds): Advanced Technology in Neurosurgery. Berlin, Springer-Verlag, 1988, pp 1-16.
    • (1988) Advanced Technology in Neurosurgery , pp. 1-16
    • Malis, L.I.1
  • 28
    • 0029832068 scopus 로고    scopus 로고
    • Electrosurgery. Technical note
    • Malis LI: Electrosurgery. Technical note. J Neurosurg 85:970-975, 1996.
    • (1996) J Neurosurg , vol.85 , pp. 970-975
    • Malis, L.I.1
  • 29
    • 33644622845 scopus 로고    scopus 로고
    • Malis LI: Electrosurgery and bipolar technology. Neurosurgery 58:ONS1-ONS12, 2006.
    • Malis LI: Electrosurgery and bipolar technology. Neurosurgery 58:ONS1-ONS12, 2006.
  • 30
    • 33846961779 scopus 로고    scopus 로고
    • Mikami T, Minamida Y, Koyanagi I, Houkin K: Novel bipolar forceps with protein repellence using gold-polytetrafluoroethylene composite film. Neurosurgery 60:ONS157-ONS161, 2007.
    • Mikami T, Minamida Y, Koyanagi I, Houkin K: Novel bipolar forceps with protein repellence using gold-polytetrafluoroethylene composite film. Neurosurgery 60:ONS157-ONS161, 2007.
  • 31
    • 0346363145 scopus 로고    scopus 로고
    • Performance of bipolar forceps during coagulation and its dependence on the tip material: A quantitative experimental assay. Technical note
    • Mikami T, Takahashi A, Hashi K, Gasa S, Houkin K: Performance of bipolar forceps during coagulation and its dependence on the tip material: A quantitative experimental assay. Technical note. J Neurosurg 100:133-138, 2004.
    • (2004) J Neurosurg , vol.100 , pp. 133-138
    • Mikami, T.1    Takahashi, A.2    Hashi, K.3    Gasa, S.4    Houkin, K.5
  • 32
    • 0030118679 scopus 로고    scopus 로고
    • William T. Bovie and electrosurgery
    • O'Connor JL, Bloom DA: William T. Bovie and electrosurgery. Surgery 119:390-396, 1996.
    • (1996) Surgery , vol.119 , pp. 390-396
    • O'Connor, J.L.1    Bloom, D.A.2
  • 33
    • 0021885425 scopus 로고
    • Bipolar diathermy forceps with automatic irrigation. Technical note
    • Ohta T, Funatsu N, Kuroiwa T, Matsui T: Bipolar diathermy forceps with automatic irrigation. Technical note. J Neurosurg 62:933-934, 1985.
    • (1985) J Neurosurg , vol.62 , pp. 933-934
    • Ohta, T.1    Funatsu, N.2    Kuroiwa, T.3    Matsui, T.4
  • 34
    • 0032768567 scopus 로고    scopus 로고
    • New bipolar diathermy forceps with automatic dripping and flushing-technical note
    • Ohta T, Kuroiwa T, Kajimoto Y: New bipolar diathermy forceps with automatic dripping and flushing-technical note. Neurol Med Chir (Tokyo) 39:548-550, 1999.
    • (1999) Neurol Med Chir (Tokyo) , vol.39 , pp. 548-550
    • Ohta, T.1    Kuroiwa, T.2    Kajimoto, Y.3
  • 36
    • 0032111490 scopus 로고    scopus 로고
    • Tissue thermal damage caused by bipolar forceps can be reduced with a combination of plastic and metal
    • Remorgida V: Tissue thermal damage caused by bipolar forceps can be reduced with a combination of plastic and metal. Surg Endosc 12:936-939, 1998.
    • (1998) Surg Endosc , vol.12 , pp. 936-939
    • Remorgida, V.1
  • 39
    • 0028958662 scopus 로고
    • Measurement of local heat generation and effects of irrigation during electrical coagulation using bipolar diathermy forceps
    • Sakatani K, Morimoto S, Ohtaki M, Hashi K: Measurement of local heat generation and effects of irrigation during electrical coagulation using bipolar diathermy forceps. Jpn J Neurosurg 4:133-137, 1995.
    • (1995) Jpn J Neurosurg , vol.4 , pp. 133-137
    • Sakatani, K.1    Morimoto, S.2    Ohtaki, M.3    Hashi, K.4
  • 40
    • 0028914464 scopus 로고
    • Isotonic mannitol and the prevention of local heat generation and tissue adherence to bipolar diathermy forceps tips during electrical coagulation. Technical note
    • Sakatani K, Ohtaki M, Morimoto S, Hashi K: Isotonic mannitol and the prevention of local heat generation and tissue adherence to bipolar diathermy forceps tips during electrical coagulation. Technical note. J Neurosurg 82:669-671, 1995.
    • (1995) J Neurosurg , vol.82 , pp. 669-671
    • Sakatani, K.1    Ohtaki, M.2    Morimoto, S.3    Hashi, K.4
  • 41
    • 0029988424 scopus 로고    scopus 로고
    • Samii A, Dujovny M: Kirwan non-stick bipolar forceps. Surg Neurol 45:297-298, 1996.
    • Samii A, Dujovny M: Kirwan "non-stick" bipolar forceps. Surg Neurol 45:297-298, 1996.
  • 43
    • 0016194790 scopus 로고
    • A new bipolar suction-cautery forceps for micro-neurosurgical use
    • Scarff TB: A new bipolar suction-cautery forceps for micro-neurosurgical use. Surg Neurol 2:213, 1974.
    • (1974) Surg Neurol , vol.2 , pp. 213
    • Scarff, T.B.1
  • 44
    • 0016266150 scopus 로고
    • Bipolar coagulator with automatic thermocontrol. Technical note
    • Sugita K, Tsugane R: Bipolar coagulator with automatic thermocontrol. Technical note. J Neurosurg 41:777-779, 1974.
    • (1974) J Neurosurg , vol.41 , pp. 777-779
    • Sugita, K.1    Tsugane, R.2
  • 45
    • 33645239061 scopus 로고    scopus 로고
    • Effect of hemostasis and electrosurgery on the development and evolution of brain tumor surgery in the late 19th and early 20th centuries
    • Vender JR, Miller J, Rekito A, McDonnell DE: Effect of hemostasis and electrosurgery on the development and evolution of brain tumor surgery in the late 19th and early 20th centuries. Neurosurg Focus 18:e3, 2005.
    • (2005) Neurosurg Focus , vol.18
    • Vender, J.R.1    Miller, J.2    Rekito, A.3    McDonnell, D.E.4
  • 47
    • 0028228285 scopus 로고
    • Experimental nerve thermal injury
    • Xu D, Pollock M: Experimental nerve thermal injury. Brain 117:375-384, 1994.
    • (1994) Brain , vol.117 , pp. 375-384
    • Xu, D.1    Pollock, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.