메뉴 건너뛰기




Volumn 24, Issue 4, 2009, Pages 403-406

A new technique for small and secure knots using slippery polyethylene sutures

Author keywords

Knot; Polyethylene; Suture; Tendon; Tensile strength

Indexed keywords

KNOT; MAXIMUM VALUES; SUTURE; SUTURE MATERIALS; UNITED STATES PHARMACOPEIAS;

EID: 62749143966     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2009.01.013     Document Type: Article
Times cited : (12)

References (20)
  • 1
    • 0031789977 scopus 로고    scopus 로고
    • Early active motion and weightbearing after cross-stitch Achilles tendon repair
    • Aoki M., Ogiwara N., Ohta T., and Nabeta Y. Early active motion and weightbearing after cross-stitch Achilles tendon repair. Am. J. Sport. Med. 26 (1998) 794-800
    • (1998) Am. J. Sport. Med. , vol.26 , pp. 794-800
    • Aoki, M.1    Ogiwara, N.2    Ohta, T.3    Nabeta, Y.4
  • 3
    • 0034045166 scopus 로고    scopus 로고
    • Effect of suture size on locking and grasping flexor tendon repair techniques
    • Hatanaka H., and Manske P.R. Effect of suture size on locking and grasping flexor tendon repair techniques. Clin. Orthop. Relat. Res. 375 (2000) 267-274
    • (2000) Clin. Orthop. Relat. Res. , vol.375 , pp. 267-274
    • Hatanaka, H.1    Manske, P.R.2
  • 4
    • 31544447485 scopus 로고    scopus 로고
    • Optimum surgical suture material and methods to obtain high tensile strength at knots: problems of conventional knots and the reinforcement effect of adhesive agent
    • Komatsu F., Mori R., and Uchio Y. Optimum surgical suture material and methods to obtain high tensile strength at knots: problems of conventional knots and the reinforcement effect of adhesive agent. J. Orthop. Sci. 11 (2006) 70-74
    • (2006) J. Orthop. Sci. , vol.11 , pp. 70-74
    • Komatsu, F.1    Mori, R.2    Uchio, Y.3
  • 5
    • 33845899996 scopus 로고    scopus 로고
    • Optimum location of knot for tendon surgery in side-locking loop technique
    • Komatsu F., Mori R., Uchio Y., and Hatanaka H. Optimum location of knot for tendon surgery in side-locking loop technique. Clin. Biomech. 22 (2007) 112-119
    • (2007) Clin. Biomech. , vol.22 , pp. 112-119
    • Komatsu, F.1    Mori, R.2    Uchio, Y.3    Hatanaka, H.4
  • 6
    • 35548933400 scopus 로고    scopus 로고
    • Flexor tendon repair using the two-strand side-locking loop technique to tolerate aggressive active mobilization immediately after surgery
    • Kuwata S., Mori R., Yotsumoto T., and Uchio Y. Flexor tendon repair using the two-strand side-locking loop technique to tolerate aggressive active mobilization immediately after surgery. Clin. Biomech. 22 (2007) 1083-1087
    • (2007) Clin. Biomech. , vol.22 , pp. 1083-1087
    • Kuwata, S.1    Mori, R.2    Yotsumoto, T.3    Uchio, Y.4
  • 7
    • 2442511176 scopus 로고    scopus 로고
    • Arthroscopic knots: determining the optimal balance of loop security and knot security
    • Lo I.K., Burkhart S.S., Chan K.C., and Athanasiou K. Arthroscopic knots: determining the optimal balance of loop security and knot security. Arthroscopy 20 (2004) 489-502
    • (2004) Arthroscopy , vol.20 , pp. 489-502
    • Lo, I.K.1    Burkhart, S.S.2    Chan, K.C.3    Athanasiou, K.4
  • 8
    • 0029123584 scopus 로고
    • Achilles tendon ruptures. A new method of repair, early range of motion, and functional rehabilitation
    • Mandelbaum B.R., Myerson M.S., and Forster R. Achilles tendon ruptures. A new method of repair, early range of motion, and functional rehabilitation. Am. J. Sport. Med. 23 (1995) 392-395
    • (1995) Am. J. Sport. Med. , vol.23 , pp. 392-395
    • Mandelbaum, B.R.1    Myerson, M.S.2    Forster, R.3
  • 10
    • 0033535813 scopus 로고    scopus 로고
    • Influence of abdominal-wound closure technique on complications after surgery: a randomized study
    • Niggebrugge A.H.P., Trimbos J.B., Hermans J., Steup W., and Van De Velde C.J.H. Influence of abdominal-wound closure technique on complications after surgery: a randomized study. Lancet 353 (1999) 1563-1567
    • (1999) Lancet , vol.353 , pp. 1563-1567
    • Niggebrugge, A.H.P.1    Trimbos, J.B.2    Hermans, J.3    Steup, W.4    Van De Velde, C.J.H.5
  • 11
    • 0030454003 scopus 로고    scopus 로고
    • Effect of suture knot location on tensile strength after flexor tendon repair
    • Pruitt D.L., Mobile A.L., Aoki M., and Manske P.R. Effect of suture knot location on tensile strength after flexor tendon repair. J. Hand Surg. Am. 21 (1996) 969-973
    • (1996) J. Hand Surg. Am. , vol.21 , pp. 969-973
    • Pruitt, D.L.1    Mobile, A.L.2    Aoki, M.3    Manske, P.R.4
  • 12
    • 0041886971 scopus 로고    scopus 로고
    • Gliding resistance versus work of flexion - two methods to assess flexor tendon repair
    • Tanaka T., Amadio P.C., Zhao C., Zobitz M.E., and An K.N. Gliding resistance versus work of flexion - two methods to assess flexor tendon repair. J. Orthop. Res. 21 (2003) 813-818
    • (2003) J. Orthop. Res. , vol.21 , pp. 813-818
    • Tanaka, T.1    Amadio, P.C.2    Zhao, C.3    Zobitz, M.E.4    An, K.N.5
  • 13
    • 0024398427 scopus 로고
    • An evaluation of suture materials used in tendon surgery
    • Trail I.A., Powell E.S., and Noble J. An evaluation of suture materials used in tendon surgery. J. Hand Surg. Br. 14 (1989) 422-427
    • (1989) J. Hand Surg. Br. , vol.14 , pp. 422-427
    • Trail, I.A.1    Powell, E.S.2    Noble, J.3
  • 14
    • 0022503847 scopus 로고
    • Performance of sliding knots in monofilament and multifilament suture material
    • Trimbos J.B., Van Rijssel E.J., and Klopper P.J. Performance of sliding knots in monofilament and multifilament suture material. Obstet. Gynecol. 68 (1986) 425-430
    • (1986) Obstet. Gynecol. , vol.68 , pp. 425-430
    • Trimbos, J.B.1    Van Rijssel, E.J.2    Klopper, P.J.3
  • 16
    • 0017758331 scopus 로고
    • Repair of flexor tendons by intratendinous tendon suture
    • Tsuge K., Ikuta Y., and Matsuishi Y. Repair of flexor tendons by intratendinous tendon suture. J. Hand Surg. 2 (1977) 436-440
    • (1977) J. Hand Surg. , vol.2 , pp. 436-440
    • Tsuge, K.1    Ikuta, Y.2    Matsuishi, Y.3
  • 17
    • 0025189721 scopus 로고
    • Mechanical performance of square knots and sliding knots in surgery: comparative study
    • van Rijssel E.J., Trimbos J.B., and Booster M.H. Mechanical performance of square knots and sliding knots in surgery: comparative study. Am. J. Obstet. Gynecol. 162 (1990) 93-97
    • (1990) Am. J. Obstet. Gynecol. , vol.162 , pp. 93-97
    • van Rijssel, E.J.1    Trimbos, J.B.2    Booster, M.H.3
  • 19
    • 0032451307 scopus 로고    scopus 로고
    • The effects of multiple-strand suture methods on the strength and excursion of repaired intrasynovial flexor tendons: a biomechanical study in dogs
    • Winters S.C., Gelberman R.H., Woo S.L., Chan S.S., Grewal R., Seiler J.G., and III. The effects of multiple-strand suture methods on the strength and excursion of repaired intrasynovial flexor tendons: a biomechanical study in dogs. J. Hand Surg. Am. 23 (1998) 97-104
    • (1998) J. Hand Surg. Am. , vol.23 , pp. 97-104
    • Winters, S.C.1    Gelberman, R.H.2    Woo, S.L.3    Chan, S.S.4    Grewal, R.5    Seiler, J.G.6    III7
  • 20
    • 0942279679 scopus 로고    scopus 로고
    • Digital resistance and tendon strength during the first week after flexor digitorum profundus tendon repair in a canine model in vivo
    • Zhao C., Amadio P.C., Paillard P., Tanaka T., Zobitz M.E., Larson D.R., and An K.N. Digital resistance and tendon strength during the first week after flexor digitorum profundus tendon repair in a canine model in vivo. J. Bone Joint Surg. Am. 86 (2004) 320-327
    • (2004) J. Bone Joint Surg. Am. , vol.86 , pp. 320-327
    • Zhao, C.1    Amadio, P.C.2    Paillard, P.3    Tanaka, T.4    Zobitz, M.E.5    Larson, D.R.6    An, K.N.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.