Volumn 46, Issue 1, 2009, Pages 144-153

Maximum noise fraction (MNF) transformation to remove ballistocardiographic artifacts in EEG signals recorded during fMRI scanning

Author keywords

Ballistocardiographic artifact; Blind source separation; Maximum noise fraction; Simultaneous EEG fMRI

Indexed keywords

ADULT; ALGORITHM; ARTICLE; ARTIFACT REDUCTION; BODY MOVEMENT; ELECTROENCEPHALOGRAPHY; EVENT RELATED POTENTIAL; FEMALE; FUNCTIONAL MAGNETIC RESONANCE IMAGING; HUMAN; HUMAN EXPERIMENT; MALE; MATHEMATICAL ANALYSIS; MATHEMATICAL COMPUTING; MAXIMUM NOISE FRACTION; MECHANOCARDIOGRAPHY; NOISE MEASUREMENT; NORMAL HUMAN; PRIORITY JOURNAL; SIGNAL NOISE RATIO; TEMPLATE SUBTRACTION METHOD; VALIDATION PROCESS;

EID: 62749117197     PISSN: 10538119     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2009.01.059     Document Type: Article
Times cited : (18)

References (32)
  • 3
    • 0017734051 scopus 로고
    • VEP and AEP variability: interlaboratory vs. intralaboratory and intersession vs. intrasession variability
    • Aunon J.I., and Cantor F.K. VEP and AEP variability: interlaboratory vs. intralaboratory and intersession vs. intrasession variability. Electroencephalogr. Clin. Neurophysiol. 42 5 (1977) 705-708
    • (1977) Electroencephalogr. Clin. Neurophysiol. , vol.42 , Issue.5 , pp. 705-708
    • Aunon, J.I.1    Cantor, F.K.2
  • 4
    • 1842455280 scopus 로고    scopus 로고
    • Optimization of an independent component analysis approach for artifact identification and removal in magnetoencephalographic signals
    • Barbati G., Porcaro C., Zappasodi F., Rossini P.M., and Tecchio F. Optimization of an independent component analysis approach for artifact identification and removal in magnetoencephalographic signals. Clin. Neurophysiol. 115 5 (2004) 1220-1232
    • (2004) Clin. Neurophysiol. , vol.115 , Issue.5 , pp. 1220-1232
    • Barbati, G.1    Porcaro, C.2    Zappasodi, F.3    Rossini, P.M.4    Tecchio, F.5
  • 5
    • 27744579731 scopus 로고    scopus 로고
    • Visual evoked potentials recovered from fMRI scan periods
    • Becker R., Ritter P., Moosmann M., and Villringer A. Visual evoked potentials recovered from fMRI scan periods. Hum. Brain Mapp. 26 (2005) 221-230
    • (2005) Hum. Brain Mapp. , vol.26 , pp. 221-230
    • Becker, R.1    Ritter, P.2    Moosmann, M.3    Villringer, A.4
  • 6
    • 0033597570 scopus 로고    scopus 로고
    • Visual evoked potential (VEP) measured by simultaneous 64-channel EEG and 3 T fMRI
    • Bonmassar G., Anami K., Ives J., and Belliveau J.W. Visual evoked potential (VEP) measured by simultaneous 64-channel EEG and 3 T fMRI. NeuroReport 10 9 (1999) 1893-1897
    • (1999) NeuroReport , vol.10 , Issue.9 , pp. 1893-1897
    • Bonmassar, G.1    Anami, K.2    Ives, J.3    Belliveau, J.W.4
  • 7
  • 9
    • 0032187518 scopus 로고    scopus 로고
    • Blind signal separation: statistical principles
    • Cardoso J.F. Blind signal separation: statistical principles. Proc. I. E. E. E. 9 (1998) 2009-2025
    • (1998) Proc. I. E. E. E. , vol.9 , pp. 2009-2025
    • Cardoso, J.F.1
  • 11
    • 39449090982 scopus 로고    scopus 로고
    • Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 T static magnetic field strength
    • Debener S., Mullinger K.J., Niazy R.K., and Bowtell R.W. Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 T static magnetic field strength. Int. J. Psychophysiol. 67 3 (2008 Mar) 189-199
    • (2008) Int. J. Psychophysiol. , vol.67 , Issue.3 , pp. 189-199
    • Debener, S.1    Mullinger, K.J.2    Niazy, R.K.3    Bowtell, R.W.4
  • 12
    • 3242665483 scopus 로고    scopus 로고
    • Ballistocardiogram artifact reduction in the simultaneous acquisition of auditory ERPS and fMRI
    • Ellingson M.L., Liebenthal E., Spanaki M.V., Prieto T.E., Binder J.R., and Ropella K.M. Ballistocardiogram artifact reduction in the simultaneous acquisition of auditory ERPS and fMRI. NeuroImage 22 4 (2004) 1534-1542
    • (2004) NeuroImage , vol.22 , Issue.4 , pp. 1534-1542
    • Ellingson, M.L.1    Liebenthal, E.2    Spanaki, M.V.3    Prieto, T.E.4    Binder, J.R.5    Ropella, K.M.6
  • 13
    • 24344436036 scopus 로고    scopus 로고
    • Using ICA for removal of ocular artifacts in EEG recorded from blind subjects
    • Flexer A., Bauer H., Pripfl J., and Dorffner G. Using ICA for removal of ocular artifacts in EEG recorded from blind subjects. Neural Netw. 18 7 (2005) 998-1005
    • (2005) Neural Netw. , vol.18 , Issue.7 , pp. 998-1005
    • Flexer, A.1    Bauer, H.2    Pripfl, J.3    Dorffner, G.4
  • 14
    • 0023854011 scopus 로고
    • A transformation for ordering multispectral data in terms of image quality with implications for noise removal
    • Green A.A., Berman M., Switzer P., and Craig M.D. A transformation for ordering multispectral data in terms of image quality with implications for noise removal. IEEE Trans. Geosci. Remote Sens. 26 1 (1988) 65-74
    • (1988) IEEE Trans. Geosci. Remote Sens. , vol.26 , Issue.1 , pp. 65-74
    • Green, A.A.1    Berman, M.2    Switzer, P.3    Craig, M.D.4
  • 15
    • 39449135873 scopus 로고    scopus 로고
    • Simultaneous recording of EEG and BOLD responses: a historical perspective
    • Herrmann C.S., and Debener S. Simultaneous recording of EEG and BOLD responses: a historical perspective. Int. J. Psychophysiol. 67 3 (2008) 161-168
    • (2008) Int. J. Psychophysiol. , vol.67 , Issue.3 , pp. 161-168
    • Herrmann, C.S.1    Debener, S.2
  • 16
    • 1642404698 scopus 로고    scopus 로고
    • A Solution Procedure for Blind Signal Separation using the Maximum Noise Fraction Approach: Algorithms and Examples
    • San Diego, CA, December
    • Hundley, D.R., Kirby, M.J., Anderle, M.G., 2001. A Solution Procedure for Blind Signal Separation using the Maximum Noise Fraction Approach: Algorithms and Examples, Proceedings of the Conference on Independent Component Analysis, San Diego, CA, 337-342, December.
    • (2001) Proceedings of the Conference on Independent Component Analysis , pp. 337-342
    • Hundley, D.R.1    Kirby, M.J.2    Anderle, M.G.3
  • 17
    • 1642356055 scopus 로고    scopus 로고
    • Blind source separation using the maximum signal fraction approach
    • Hundley D.R., Kirby M.J., and Anderle M. Blind source separation using the maximum signal fraction approach. Signal Process. 82 (2002) 1505-1508
    • (2002) Signal Process. , vol.82 , pp. 1505-1508
    • Hundley, D.R.1    Kirby, M.J.2    Anderle, M.3
  • 18
    • 0032629347 scopus 로고    scopus 로고
    • Fast and robust fixed-point algorithms for independent component analysis
    • Hyvaerinen A. Fast and robust fixed-point algorithms for independent component analysis. IEEE Trans. Neural Netw. 10 3 (1999) 626-634
    • (1999) IEEE Trans. Neural Netw. , vol.10 , Issue.3 , pp. 626-634
    • Hyvaerinen, A.1
  • 20
    • 1942472547 scopus 로고    scopus 로고
    • Automatic removal of eye movement and blink artifacts from EEG data using blind component separation
    • Joyce C.A., Gorodnitsky I.F., and Kutas M. Automatic removal of eye movement and blink artifacts from EEG data using blind component separation. Psychophysiology 41 2 (2004) 313-325
    • (2004) Psychophysiology , vol.41 , Issue.2 , pp. 313-325
    • Joyce, C.A.1    Gorodnitsky, I.F.2    Kutas, M.3
  • 21
    • 1542723008 scopus 로고    scopus 로고
    • Improved ballistocardiac artifact removal from the electroencephalogram recorded in fMRI
    • Kim K.H., Yoon H.W., and Park H.W. Improved ballistocardiac artifact removal from the electroencephalogram recorded in fMRI. J. Neurosci. Methods 135 1-2 (2004) 193-203
    • (2004) J. Neurosci. Methods , vol.135 , Issue.1-2 , pp. 193-203
    • Kim, K.H.1    Yoon, H.W.2    Park, H.W.3
  • 23
    • 35148821509 scopus 로고    scopus 로고
    • Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis
    • (Jan 15)
    • Mantini D., Perrucci M.G., Cugini S., Ferretti A., Romani G.L., and Del Gratta C. Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis. NeuroImage 34 2 (2007) 598-607 (Jan 15)
    • (2007) NeuroImage , vol.34 , Issue.2 , pp. 598-607
    • Mantini, D.1    Perrucci, M.G.2    Cugini, S.3    Ferretti, A.4    Romani, G.L.5    Del Gratta, C.6
  • 24
    • 33746829245 scopus 로고    scopus 로고
    • Removal of ballistocardiogram artifacts from simultaneously recorded EEG and fMRI data using independent component analysis
    • Nakamura W., Anami K., Mori T., Saitoh O., Cichocki A., and Amari S. Removal of ballistocardiogram artifacts from simultaneously recorded EEG and fMRI data using independent component analysis. IEEE Trans. Biomed. Eng. 53 7 (2006) 1294-1308
    • (2006) IEEE Trans. Biomed. Eng. , vol.53 , Issue.7 , pp. 1294-1308
    • Nakamura, W.1    Anami, K.2    Mori, T.3    Saitoh, O.4    Cichocki, A.5    Amari, S.6
  • 25
    • 3843102642 scopus 로고    scopus 로고
    • Removal of time-varying gradient artifacts from EEG data acquired during continuous fMRI
    • Negishi M., Abildgaard M., Nixon T., and Constable R.T. Removal of time-varying gradient artifacts from EEG data acquired during continuous fMRI. Clin. Neurophysiol. 115 9 (2004) 2181-2192
    • (2004) Clin. Neurophysiol. , vol.115 , Issue.9 , pp. 2181-2192
    • Negishi, M.1    Abildgaard, M.2    Nixon, T.3    Constable, R.T.4
  • 26
    • 27544446124 scopus 로고    scopus 로고
    • Removal of FMRI environment artifacts from EEG data using optimal basis sets
    • Niazy R.K., Beckmann C.F., Iannetti G.D., Brady J.M., and Smith S.M. Removal of FMRI environment artifacts from EEG data using optimal basis sets. NeuroImage 28 3 (2005) 720-737
    • (2005) NeuroImage , vol.28 , Issue.3 , pp. 720-737
    • Niazy, R.K.1    Beckmann, C.F.2    Iannetti, G.D.3    Brady, J.M.4    Smith, S.M.5
  • 27
    • 0030911755 scopus 로고    scopus 로고
    • On the relationship between EEG and P300: individual differences, aging, and ultradian rhythms
    • (Jun)
    • Polich J. On the relationship between EEG and P300: individual differences, aging, and ultradian rhythms. Int. J. Psychophysiol. 26 1-3 (1997) 299-317 (Jun)
    • (1997) Int. J. Psychophysiol. , vol.26 , Issue.1-3 , pp. 299-317
    • Polich, J.1
  • 28
    • 0033772320 scopus 로고    scopus 로고
    • Reduction of ECG and gradient related artifacts in simultaneously recorded human EEG/MRI data
    • Sijbers J., Van Audekerke J., Verhoye M., Van der Linden A., and Van Dyck D. Reduction of ECG and gradient related artifacts in simultaneously recorded human EEG/MRI data. Magn. Reson. Imaging 18 7 (2000) 881-886
    • (2000) Magn. Reson. Imaging , vol.18 , Issue.7 , pp. 881-886
    • Sijbers, J.1    Van Audekerke, J.2    Verhoye, M.3    Van der Linden, A.4    Van Dyck, D.5
  • 29
    • 10044290880 scopus 로고    scopus 로고
    • ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner
    • Srivastava G., Crottaz-Herbette S., Lau K.M., Glover G.H., and Menon V. ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner. NeuroImage 24 1 (2005) 50-60
    • (2005) NeuroImage , vol.24 , Issue.1 , pp. 50-60
    • Srivastava, G.1    Crottaz-Herbette, S.2    Lau, K.M.3    Glover, G.H.4    Menon, V.5
  • 30
    • 0035878735 scopus 로고    scopus 로고
    • Removal of ECG interference from the EEG recordings in small animals using independent component analysis
    • Tong S., Bezerianos A., Paul J., Zhu Y., and Thakor N. Removal of ECG interference from the EEG recordings in small animals using independent component analysis. J. Neurosci. Methods 108 2001 (2001) 11-17
    • (2001) J. Neurosci. Methods , vol.108 , Issue.2001 , pp. 11-17
    • Tong, S.1    Bezerianos, A.2    Paul, J.3    Zhu, Y.4    Thakor, N.5
  • 31
    • 33644748311 scopus 로고    scopus 로고
    • Artifact reduction for EEG/fMRI recording: nonlinear reduction of ballistocardiogram artifacts
    • Wan X., Iwata K., Riera J., Ozaki T., Kitamura M., and Kawashima R. Artifact reduction for EEG/fMRI recording: nonlinear reduction of ballistocardiogram artifacts. Clin. Neurophysiol. 117 3 (2006) 668-680
    • (2006) Clin. Neurophysiol. , vol.117 , Issue.3 , pp. 668-680
    • Wan, X.1    Iwata, K.2    Riera, J.3    Ozaki, T.4    Kitamura, M.5    Kawashima, R.6
  • 32
    • 84908144695 scopus 로고
    • The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodograms
    • Welch P.D. The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodograms. IEEE Trans. Audio Electroacoust. 15 (1967) 17-20
    • (1967) IEEE Trans. Audio Electroacoust. , vol.15 , pp. 17-20
    • Welch, P.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.