메뉴 건너뛰기




Volumn 42, Issue 6, 2009, Pages 665-670

A method to quantify alteration of knee kinematics caused by changes of TKR positioning

Author keywords

Kinematics; Knee prosthesis; Navigation; Orientation; Position

Indexed keywords

ARTHROTOMY; EXTERNAL ROTATIONS; FEMORAL COMPONENTS; IMPLANT COMPONENTS; IN-VITRO; KNEE FLEXIONS; KNEE KINEMATICS; KNEE PROSTHESIS; ORIENTATION; POSITION; SOFT TISSUES; SURGICAL NAVIGATION SYSTEMS; TEST RIGS; TOTAL KNEE REPLACEMENTS;

EID: 62749110675     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2009.01.006     Document Type: Article
Times cited : (11)

References (20)
  • 2
    • 0030175447 scopus 로고    scopus 로고
    • Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    • Banks S.A., and Hodge W.A. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans. Biomed. Eng. 43 (1996) 638-649
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , pp. 638-649
    • Banks, S.A.1    Hodge, W.A.2
  • 3
    • 0031543693 scopus 로고    scopus 로고
    • In-vivo kinematics of cruciate-retaining and substituting knee arthroplasties
    • Banks S.A., Markovich G.D., and Hodge W.A. In-vivo kinematics of cruciate-retaining and substituting knee arthroplasties. J. Arthroplasty 12 (1997) 297-304
    • (1997) J. Arthroplasty , vol.12 , pp. 297-304
    • Banks, S.A.1    Markovich, G.D.2    Hodge, W.A.3
  • 4
    • 33748304160 scopus 로고    scopus 로고
    • Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo
    • Benoit D.L., Ramsey D.K., Lamontagne M., Xu L., Wretenberg P., and Renström P. Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo. Gait Posture 24 (2006) 152-164
    • (2006) Gait Posture , vol.24 , pp. 152-164
    • Benoit, D.L.1    Ramsey, D.K.2    Lamontagne, M.3    Xu, L.4    Wretenberg, P.5    Renström, P.6
  • 5
    • 0032418168 scopus 로고    scopus 로고
    • Malrotation causing patellofemoral complications after total knee arthroplasty
    • Berger R.A., Crossett L.S., Jacobs J.J., and Rubash H.E. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin. Orthop. 356 (1998) 144-153
    • (1998) Clin. Orthop. , vol.356 , pp. 144-153
    • Berger, R.A.1    Crossett, L.S.2    Jacobs, J.J.3    Rubash, H.E.4
  • 6
    • 0027400765 scopus 로고
    • Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis
    • Berger R.A., Rubash H.E., Seel M.J., Thompson W.H., and Crossett L.S. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin. Orthop. 286 (1993) 40-47
    • (1993) Clin. Orthop. , vol.286 , pp. 40-47
    • Berger, R.A.1    Rubash, H.E.2    Seel, M.J.3    Thompson, W.H.4    Crossett, L.S.5
  • 8
    • 0022537079 scopus 로고
    • Technical considerations in total knee arthroplasty
    • Dorr L.D., and Boiardo R.A. Technical considerations in total knee arthroplasty. Clin. Orthop. Relat. Res. 205 (1986) 5-11
    • (1986) Clin. Orthop. Relat. Res. , vol.205 , pp. 5-11
    • Dorr, L.D.1    Boiardo, R.A.2
  • 9
    • 0023837479 scopus 로고
    • Limits of movement in the human knee. Effect of sectioning the posterior cruciate ligament and posterolateral structures
    • Grood E.S., Stowers S.F., and Noyes F.R. Limits of movement in the human knee. Effect of sectioning the posterior cruciate ligament and posterolateral structures. J. Bone Joint Surg. Am. 70-A (1988) 88-97
    • (1988) J. Bone Joint Surg. Am. , vol.70 -A , pp. 88-97
    • Grood, E.S.1    Stowers, S.F.2    Noyes, F.R.3
  • 10
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: application to the knee
    • Grood E.S., and Suntay W.J. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. Trans. ASME J. Biomed. Eng. 105 (1983) 133-144
    • (1983) Trans. ASME J. Biomed. Eng. , vol.105 , pp. 133-144
    • Grood, E.S.1    Suntay, W.J.2
  • 11
    • 33845750506 scopus 로고    scopus 로고
    • Sagittal curvature of total knee replacements predicts in vivo kinematics
    • Kessler O., Durselen L., Banks S., Mannel H., and Marin F. Sagittal curvature of total knee replacements predicts in vivo kinematics. Clin. Biomech. 22 (2007) 52-58
    • (2007) Clin. Biomech. , vol.22 , pp. 52-58
    • Kessler, O.1    Durselen, L.2    Banks, S.3    Mannel, H.4    Marin, F.5
  • 12
    • 33750627923 scopus 로고    scopus 로고
    • Computer-assisted navigation in TKA: where we are and where we are going
    • Laskin R.S., and Beksac B. Computer-assisted navigation in TKA: where we are and where we are going. Clin. Orthop. Relat. Res. 452 (2006) 127-131
    • (2006) Clin. Orthop. Relat. Res. , vol.452 , pp. 127-131
    • Laskin, R.S.1    Beksac, B.2
  • 13
    • 62749114877 scopus 로고    scopus 로고
    • Effect of internal-external rotation position of the femoral component on kinematics of the knee post TKR
    • Lucas D.J., Alam M., Bull A.M.J., Kessler O., and Amis A.A. Effect of internal-external rotation position of the femoral component on kinematics of the knee post TKR. J. Bone Joint Surg. Br. Proc. 88-B (2006) 444
    • (2006) J. Bone Joint Surg. Br. Proc. , vol.88 -B , pp. 444
    • Lucas, D.J.1    Alam, M.2    Bull, A.M.J.3    Kessler, O.4    Amis, A.A.5
  • 17
    • 0342804263 scopus 로고    scopus 로고
    • In vivo kinematics of total knee arthroplasty. Concave versus posterior-stabilised tibial joint surface
    • Uvehammer J., Kärrholm J., and Brandsson S. In vivo kinematics of total knee arthroplasty. Concave versus posterior-stabilised tibial joint surface. J. Bone Joint Surg. Br. 82-B (2000) 499-505
    • (2000) J. Bone Joint Surg. Br. , vol.82 -B , pp. 499-505
    • Uvehammer, J.1    Kärrholm, J.2    Brandsson, S.3
  • 18
    • 0035046841 scopus 로고    scopus 로고
    • Knee Joint kinematics, fixation and function related to joint area design in total knee arthroplasty
    • (Thesis)
    • Uvehammer J. Knee Joint kinematics, fixation and function related to joint area design in total knee arthroplasty. Acta Orthop. Scand. Suppl. 72 (2001) 1-52 (Thesis)
    • (2001) Acta Orthop. Scand. Suppl. , vol.72 , pp. 1-52
    • Uvehammer, J.1
  • 19
    • 0028826025 scopus 로고
    • The anteroposterior axis for femoral rotational alignment in valgus total knee arthroplasty
    • Whiteside L.A., and Arima J. The anteroposterior axis for femoral rotational alignment in valgus total knee arthroplasty. Clin. Orthop. Relat. Res. 321 (1995) 168-172
    • (1995) Clin. Orthop. Relat. Res. , vol.321 , pp. 168-172
    • Whiteside, L.A.1    Arima, J.2
  • 20
    • 33750373843 scopus 로고    scopus 로고
    • Three-dimensional kinematics and kinetics of total knee arthroplasty during level walking using single plane video-fluoroscopy and force plates: a pilot study
    • Zihlmann M.S., Gerber H., Stacoff A., Burckhardt K., Szekely G., and Stussi E. Three-dimensional kinematics and kinetics of total knee arthroplasty during level walking using single plane video-fluoroscopy and force plates: a pilot study. Gait Posture 24 (2006) 475-481
    • (2006) Gait Posture , vol.24 , pp. 475-481
    • Zihlmann, M.S.1    Gerber, H.2    Stacoff, A.3    Burckhardt, K.4    Szekely, G.5    Stussi, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.