메뉴 건너뛰기




Volumn 4, Issue 1, 2009, Pages 106-110

Electrochemical detection of self-assembled viologen modified electrode as mediator of glucose sensor

Author keywords

Detection limit; Glucose biosensor; Glucose oxidase; Mediator; Viologen

Indexed keywords

BIOSENSORS; CHARGE TRANSFER; CHEMICAL DETECTION; CHEMICAL SENSORS; ELECTRODES; GLUCOSE; GLUCOSE OXIDASE; GLUCOSE SENSORS; GOLD; QUARTZ CRYSTAL MICROBALANCES; SELF ASSEMBLED MONOLAYERS;

EID: 62649105232     PISSN: 19750102     EISSN: None     Source Type: Journal    
DOI: 10.5370/JEET.2009.4.1.106     Document Type: Article
Times cited : (5)

References (12)
  • 1
    • 10244223555 scopus 로고
    • Electrode systems for continuous monitoring cardiovascular surgery
    • L. Clark and C. Lyons, "Electrode systems for continuous monitoring cardiovascular surgery", Ann. NY Acad. Sci., 102 (1962) 29.
    • (1962) Ann. NY Acad. Sci , vol.102 , pp. 29
    • Clark, L.1    Lyons, C.2
  • 2
    • 0014191637 scopus 로고
    • The enzyme electrode
    • S. J. Updike and J. P. Hicks, "The enzyme electrode", Nature, 214 (1967) 986.
    • (1967) Nature , vol.214 , pp. 986
    • Updike, S.J.1    Hicks, J.P.2
  • 3
    • 0037162586 scopus 로고    scopus 로고
    • Quartz Crystal Microbalance and Electrochemical Studies on a Viologen Thiol Incorporated in Phospholipid Self-Assembled Monolayers
    • N. Nakamura, H.-X. Huang, D.-J. Qian and J. Miyake, "Quartz Crystal Microbalance and Electrochemical Studies on a Viologen Thiol Incorporated in Phospholipid Self-Assembled Monolayers", Langmuir, 18 (2002) 5804.
    • (2002) Langmuir , vol.18 , pp. 5804
    • Nakamura, N.1    Huang, H.-X.2    Qian, D.-J.3    Miyake, J.4
  • 4
    • 33646939547 scopus 로고    scopus 로고
    • D.-Y. Lee, A.K.M. Kafi, S.-H. Park, D.-J. Qian, Y.-S. Kwon, Influence of Anions on Electrochemical Redox Reaction and Electrical Property using Viologen Derivative, Jpn. J. Appl. Phys., 45 (4B) (2006) 3772.
    • D.-Y. Lee, A.K.M. Kafi, S.-H. Park, D.-J. Qian, Y.-S. Kwon, "Influence of Anions on Electrochemical Redox Reaction and Electrical Property using Viologen Derivative", Jpn. J. Appl. Phys., 45 (4B) (2006) 3772.
  • 5
    • 33845770387 scopus 로고    scopus 로고
    • Charge Transfer Property of Self-Assembled Viologen Derivative by Electrochemical Quartz Crystal Microbalance Response
    • D.-Y. Lee, A.K.M. Kafi, S.-H. Park, Y.-S. Kwon, "Charge Transfer Property of Self-Assembled Viologen Derivative by Electrochemical Quartz Crystal Microbalance Response", J. Nanosci. Nanotechnol., 6 (2006) 3657.
    • (2006) J. Nanosci. Nanotechnol , vol.6 , pp. 3657
    • Lee, D.-Y.1    Kafi, A.K.M.2    Park, S.-H.3    Kwon, Y.-S.4
  • 6
    • 33847152559 scopus 로고    scopus 로고
    • Development of a peroxide biosensor made of a thiolated-viologen and hemoglobin-modified gold electrode
    • A.K.M. Kafi, D.-Y. Lee, S.-H. Park, Y.-S. Kwon, "Development of a peroxide biosensor made of a thiolated-viologen and hemoglobin-modified gold electrode", Microchem. J., 85 (2007) 308.
    • (2007) Microchem. J , vol.85 , pp. 308
    • Kafi, A.K.M.1    Lee, D.-Y.2    Park, S.-H.3    Kwon, Y.-S.4
  • 7
    • 15044358725 scopus 로고    scopus 로고
    • Study on the electrochemical behavior of the viologen monolayers by different chemical structure
    • J.-Y. Ock, H.-K. Shin, Y.-S. Kwon, J. Miyake, "Study on the electrochemical behavior of the viologen monolayers by different chemical structure", Colloid. Surface. A, 257 (2005) 351.
    • (2005) Colloid. Surface. A , vol.257 , pp. 351
    • Ock, J.-Y.1    Shin, H.-K.2    Kwon, Y.-S.3    Miyake, J.4
  • 8
    • 55849113019 scopus 로고    scopus 로고
    • Immobilization, Hybridization and Amperometric Detection of DNA Sensor Using Quartz Crystal Microbalance
    • D.-Y. Lee, W.-S. Choi, A.K.M. Kafi, S.-H. Park, Y.-S. Kwon, "Immobilization, Hybridization and Amperometric Detection of DNA Sensor Using Quartz Crystal Microbalance", J. Nanosci. Nanotechnol., 8 (2008) 4553.
    • (2008) J. Nanosci. Nanotechnol , vol.8 , pp. 4553
    • Lee, D.-Y.1    Choi, W.-S.2    Kafi, A.K.M.3    Park, S.-H.4    Kwon, Y.-S.5
  • 9
    • 0000034324 scopus 로고    scopus 로고
    • Development of a hypoxanthine biosensor based on immobilized xanthine oxidase chemically modified electrode
    • S. Hu, C.-C. Liu, "Development of a hypoxanthine biosensor based on immobilized xanthine oxidase chemically modified electrode", Electroanal., 9 (1997) 372.
    • (1997) Electroanal , vol.9 , pp. 372
    • Hu, S.1    Liu, C.-C.2
  • 10
    • 14744278404 scopus 로고    scopus 로고
    • A glucose biosensor using methyl viologen redox mediator on carbon film electrodes
    • M. E. Ghica, Christopher M. A. Brett, "A glucose biosensor using methyl viologen redox mediator on carbon film electrodes", Anal. Chim. Acta, 532 (2005) 145.
    • (2005) Anal. Chim. Acta , vol.532 , pp. 145
    • Ghica, M.E.1    Christopher, M.2    Brett, A.3
  • 11
    • 31544440975 scopus 로고    scopus 로고
    • Hydrogen peroxide biosensor based on DNA-Hb modified gold electrode
    • A.K.M. Kafi, F. Yin, H.-K. Shin, Y.-S. Kwon, "Hydrogen peroxide biosensor based on DNA-Hb modified gold electrode", Thin Solid Films, 499 (2006) 420.
    • (2006) Thin Solid Films , vol.499 , pp. 420
    • Kafi, A.K.M.1    Yin, F.2    Shin, H.-K.3    Kwon, Y.-S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.