-
1
-
-
51249112320
-
Hemostats, sealants, and adhesives: components of the surgical toolbox
-
Spotnitz W.D., and Burks S. Hemostats, sealants, and adhesives: components of the surgical toolbox. Transfusion 48 (2008) 1502-1516
-
(2008)
Transfusion
, vol.48
, pp. 1502-1516
-
-
Spotnitz, W.D.1
Burks, S.2
-
2
-
-
0142227999
-
Surgical tissue adhesives: new additions to the surgical armamentarium
-
Spotnitz W.D. Surgical tissue adhesives: new additions to the surgical armamentarium. J Long Term Eff Med Implants 13 (2003) 385-387
-
(2003)
J Long Term Eff Med Implants
, vol.13
, pp. 385-387
-
-
Spotnitz, W.D.1
-
3
-
-
0027579855
-
Fibrin sealant adhesive systems: a review of their chemistry, material properties and clinical applications
-
Sierra D.H. Fibrin sealant adhesive systems: a review of their chemistry, material properties and clinical applications. J Biomater Appl 7 (1993) 309-352
-
(1993)
J Biomater Appl
, vol.7
, pp. 309-352
-
-
Sierra, D.H.1
-
4
-
-
0026457873
-
Effects of antifibrinolytic agents on the life span of fibrin sealant
-
Pipan C.M., Glasheen W.P., Matthew T.L., et al. Effects of antifibrinolytic agents on the life span of fibrin sealant. J Surg Res 53 (1992) 402-407
-
(1992)
J Surg Res
, vol.53
, pp. 402-407
-
-
Pipan, C.M.1
Glasheen, W.P.2
Matthew, T.L.3
-
5
-
-
0034801735
-
A tissue sealant based on reactive multifunctional polyethylene glycol
-
Wallace D.G., Cruise G.M., Rhee W.M., et al. A tissue sealant based on reactive multifunctional polyethylene glycol. J Biomed Mater Res 58 (2001) 545-555
-
(2001)
J Biomed Mater Res
, vol.58
, pp. 545-555
-
-
Wallace, D.G.1
Cruise, G.M.2
Rhee, W.M.3
-
6
-
-
0345688633
-
BioGlue: albumin/glutaraldehyde sealant in cardiac surgery
-
Chao H.H., and Torchiana D.F. BioGlue: albumin/glutaraldehyde sealant in cardiac surgery. J Card Surg 18 (2003) 500-503
-
(2003)
J Card Surg
, vol.18
, pp. 500-503
-
-
Chao, H.H.1
Torchiana, D.F.2
-
7
-
-
40849133925
-
On the mechanical properties of bovine serum albumin (BSA) adhesives
-
Berchane N.S., Andrews M.J., Kerr S., Slater N.K., and Jebrail F.F. On the mechanical properties of bovine serum albumin (BSA) adhesives. J Mater Sci Mater Med 19 (2008) 1831-1838
-
(2008)
J Mater Sci Mater Med
, vol.19
, pp. 1831-1838
-
-
Berchane, N.S.1
Andrews, M.J.2
Kerr, S.3
Slater, N.K.4
Jebrail, F.F.5
-
8
-
-
0442313595
-
Comparative study of the mechanical behaviour of a cyanoacrylate and a bioadhesive
-
García Páez J.M., Jorge Herrero E., Rocha A., et al. Comparative study of the mechanical behaviour of a cyanoacrylate and a bioadhesive. J Mater Sci Mater Med 15 (2004) 109-115
-
(2004)
J Mater Sci Mater Med
, vol.15
, pp. 109-115
-
-
García Páez, J.M.1
Jorge Herrero, E.2
Rocha, A.3
-
9
-
-
43049168710
-
Asymmetric mechanical properties of porcine aortic sinuses
-
Gundiah N., Kam K., Matthews P.B., et al. Asymmetric mechanical properties of porcine aortic sinuses. Ann Thorac Surg 85 (2008) 1631-1638
-
(2008)
Ann Thorac Surg
, vol.85
, pp. 1631-1638
-
-
Gundiah, N.1
Kam, K.2
Matthews, P.B.3
-
10
-
-
29444450110
-
Cerebrospinal fluid leak rate after the use of BioGlue in translabyrinthine vestibular schwannoma surgery: a prospective study
-
Sen A., Green K.M., Khan M.I., Saeed S.R., and Ramsden R.T. Cerebrospinal fluid leak rate after the use of BioGlue in translabyrinthine vestibular schwannoma surgery: a prospective study. Otol Neurotol 27 (2006) 102-105
-
(2006)
Otol Neurotol
, vol.27
, pp. 102-105
-
-
Sen, A.1
Green, K.M.2
Khan, M.I.3
Saeed, S.R.4
Ramsden, R.T.5
-
11
-
-
36049010055
-
Mechanical properties and microscopic findings of a Dacron graft explanted 27 years after coarctation repair
-
Nagano N., Cartier R., Zigras T., Mongrain R., and Leask R.L. Mechanical properties and microscopic findings of a Dacron graft explanted 27 years after coarctation repair. J Thorac Cardiovasc Surg 134 (2007) 1577-1578
-
(2007)
J Thorac Cardiovasc Surg
, vol.134
, pp. 1577-1578
-
-
Nagano, N.1
Cartier, R.2
Zigras, T.3
Mongrain, R.4
Leask, R.L.5
-
12
-
-
0031239687
-
Porcine aortic wall flexibility. Fresh vs Denacol fixed vs glutaraldehyde fixed
-
Zhou J., Quintero L.J., Helmus M.N., Lee C., and Kafesjian R. Porcine aortic wall flexibility. Fresh vs Denacol fixed vs glutaraldehyde fixed. ASAIO J 43 (1997) M470-M475
-
(1997)
ASAIO J
, vol.43
-
-
Zhou, J.1
Quintero, L.J.2
Helmus, M.N.3
Lee, C.4
Kafesjian, R.5
-
13
-
-
62649093562
-
Local mechanical and structural properties of healthy and diseased human ascending aorta tissue
-
Mar 3 [Epub ahead of print]
-
Choudhury N., Bouchot O., Rouleau L., et al. Local mechanical and structural properties of healthy and diseased human ascending aorta tissue. Cardiovasc Pathol (2008) Mar 3 [Epub ahead of print]
-
(2008)
Cardiovasc Pathol
-
-
Choudhury, N.1
Bouchot, O.2
Rouleau, L.3
-
14
-
-
0442292380
-
Application of biological glue in repair of intracardiac structural defects
-
Fink D., Klein J.J., Kang H., and Ergin M.A. Application of biological glue in repair of intracardiac structural defects. Ann Thorac Surg 77 (2004) 506-511
-
(2004)
Ann Thorac Surg
, vol.77
, pp. 506-511
-
-
Fink, D.1
Klein, J.J.2
Kang, H.3
Ergin, M.A.4
-
15
-
-
0030341759
-
Controlled clinical studies of fibrin sealant in cardiothoracic surgery-a review
-
Kjaergard H.K., and Fairbrother J.E. Controlled clinical studies of fibrin sealant in cardiothoracic surgery-a review. Eur J Cardiothorac Surg 10 (1996) 727-733
-
(1996)
Eur J Cardiothorac Surg
, vol.10
, pp. 727-733
-
-
Kjaergard, H.K.1
Fairbrother, J.E.2
-
16
-
-
0034909220
-
Use of "BioGlue" in aortic surgical repair
-
Raanani E., Latter D.A., Errett L.E., Bonneau D.B., Leclerc Y., and Salasidis G.C. Use of "BioGlue" in aortic surgical repair. Ann Thorac Surg 72 (2001) 638-640
-
(2001)
Ann Thorac Surg
, vol.72
, pp. 638-640
-
-
Raanani, E.1
Latter, D.A.2
Errett, L.E.3
Bonneau, D.B.4
Leclerc, Y.5
Salasidis, G.C.6
-
17
-
-
0028805322
-
Comparative study of biological glues: cryoprecipitate glue, two-component fibrin sealant, and "French" glue
-
Basu S., Marini C.P., Bauman F.G., et al. Comparative study of biological glues: cryoprecipitate glue, two-component fibrin sealant, and "French" glue. Ann Thorac Surg 60 (1995) 1255-1262
-
(1995)
Ann Thorac Surg
, vol.60
, pp. 1255-1262
-
-
Basu, S.1
Marini, C.P.2
Bauman, F.G.3
-
18
-
-
34548132114
-
Use of bovine albumin-glutaraldehyde glue in cardiovascular surgery
-
Zehr K.J. Use of bovine albumin-glutaraldehyde glue in cardiovascular surgery. Ann Thorac Surg 84 (2007) 1048-1052
-
(2007)
Ann Thorac Surg
, vol.84
, pp. 1048-1052
-
-
Zehr, K.J.1
-
19
-
-
24644486014
-
Pre-emptive placement of a presealant for amniotic access
-
Cortes R.A., Wagner A.J., Lee H., et al. Pre-emptive placement of a presealant for amniotic access. Am J Obstet Gynecol 193 3 Pt 2 (2005) 1197-1203
-
(2005)
Am J Obstet Gynecol
, vol.193
, Issue.3 PART 2
, pp. 1197-1203
-
-
Cortes, R.A.1
Wagner, A.J.2
Lee, H.3
-
20
-
-
0043167983
-
Prospective randomized study of a protein-based tissue adhesive used as a hemostatic and structural adjunct in cardiac and vascular anastomotic repair procedures
-
Coselli J.S., Bavaria J.E., Fehrenbacher J., Stowe C.L., Macheers S.K., and Gundry S.R. Prospective randomized study of a protein-based tissue adhesive used as a hemostatic and structural adjunct in cardiac and vascular anastomotic repair procedures. J Am Coll Surg 197 (2003) 243-253
-
(2003)
J Am Coll Surg
, vol.197
, pp. 243-253
-
-
Coselli, J.S.1
Bavaria, J.E.2
Fehrenbacher, J.3
Stowe, C.L.4
Macheers, S.K.5
Gundry, S.R.6
-
21
-
-
0036192268
-
A polymeric sealant inhibits anastomotic suture hole bleeding more rapidly than gelfoam/thrombin: results of a randomized controlled trial
-
CoSeal Multicenter Vascular Surgery Study Group
-
Glickman M., Gheissari A., Money S., Martin J., Ballard J.L., and CoSeal Multicenter Vascular Surgery Study Group. A polymeric sealant inhibits anastomotic suture hole bleeding more rapidly than gelfoam/thrombin: results of a randomized controlled trial. Arch Surg 137 (2002) 326-332
-
(2002)
Arch Surg
, vol.137
, pp. 326-332
-
-
Glickman, M.1
Gheissari, A.2
Money, S.3
Martin, J.4
Ballard, J.L.5
-
22
-
-
0036266279
-
BioGlue surgical adhesive impairs aortic growth and causes anastomotic strictures
-
LeMaire S.A., Schmittling Z.C., Coselli J.S., et al. BioGlue surgical adhesive impairs aortic growth and causes anastomotic strictures. Ann Thorac Surg 73 (2002) 1500-1506
-
(2002)
Ann Thorac Surg
, vol.73
, pp. 1500-1506
-
-
LeMaire, S.A.1
Schmittling, Z.C.2
Coselli, J.S.3
-
23
-
-
0036839842
-
Advances in the treatment of acute type A dissection: an integrated approach
-
Bavaria J.E., Brinster D.R., Gorman R.C., Woo Y.J., Gleason T., and Pochettino A. Advances in the treatment of acute type A dissection: an integrated approach. Ann Thorac Surg 74 (2002) S1848-S1863
-
(2002)
Ann Thorac Surg
, vol.74
-
-
Bavaria, J.E.1
Brinster, D.R.2
Gorman, R.C.3
Woo, Y.J.4
Gleason, T.5
Pochettino, A.6
-
24
-
-
0036212190
-
Cause of degenerative disease of the trileaflet aortic valve: review of subject and presentation of a new theory
-
Robicsek F., Thubrikar M.J., and Fokin A.A. Cause of degenerative disease of the trileaflet aortic valve: review of subject and presentation of a new theory. Ann Thorac Surg 73 (2002) 1346-1354
-
(2002)
Ann Thorac Surg
, vol.73
, pp. 1346-1354
-
-
Robicsek, F.1
Thubrikar, M.J.2
Fokin, A.A.3
-
25
-
-
18144392645
-
Effective use of fibrin glue for acute aortic dissection
-
Nakajima T., Kawazoe K., Izumoto H., Kataoka T., and Kazui T. Effective use of fibrin glue for acute aortic dissection. Ann Thorac Surg 79 (2005) 1793-1794
-
(2005)
Ann Thorac Surg
, vol.79
, pp. 1793-1794
-
-
Nakajima, T.1
Kawazoe, K.2
Izumoto, H.3
Kataoka, T.4
Kazui, T.5
-
26
-
-
34247271872
-
Midterm results of aortic repair using a fabric neomedia and fibrin glue for type A acute aortic dissection
-
Nakajima T., Kawazoe K., Kataoka T., et al. Midterm results of aortic repair using a fabric neomedia and fibrin glue for type A acute aortic dissection. Ann Thorac Surg 83 (2007) 1615-1620
-
(2007)
Ann Thorac Surg
, vol.83
, pp. 1615-1620
-
-
Nakajima, T.1
Kawazoe, K.2
Kataoka, T.3
-
27
-
-
0028145080
-
Aortic valve repair with fibrin glue for type A acute aortic dissection
-
Séguin J.R., Picard E., Frapier J.M., and Chaptal P.A. Aortic valve repair with fibrin glue for type A acute aortic dissection. Ann Thorac Surg 58 (1994) 304-307
-
(1994)
Ann Thorac Surg
, vol.58
, pp. 304-307
-
-
Séguin, J.R.1
Picard, E.2
Frapier, J.M.3
Chaptal, P.A.4
-
28
-
-
0028020659
-
Repair of the aortic arch with fibrin glue in type A aortic dissection
-
Séguin J.R., Picard E., Frapier J.M., and Chaptal P.A. Repair of the aortic arch with fibrin glue in type A aortic dissection. J Card Surg 9 (1994) 734-739
-
(1994)
J Card Surg
, vol.9
, pp. 734-739
-
-
Séguin, J.R.1
Picard, E.2
Frapier, J.M.3
Chaptal, P.A.4
-
29
-
-
0034907366
-
Role of biologic glue repair of proximal aortic dissection in the development of early and midterm redissection of the aortic root
-
Kazui T., Washiyama N., Bashar A.H., et al. Role of biologic glue repair of proximal aortic dissection in the development of early and midterm redissection of the aortic root. Ann Thorac Surg 72 (2001) 509-514
-
(2001)
Ann Thorac Surg
, vol.72
, pp. 509-514
-
-
Kazui, T.1
Washiyama, N.2
Bashar, A.H.3
-
31
-
-
18144423828
-
Release of glutaraldehyde from an albumin-glutaraldehyde tissue adhesive causes significant in vitro and in vivo toxicity
-
Fürst W., and Banerjee A. Release of glutaraldehyde from an albumin-glutaraldehyde tissue adhesive causes significant in vitro and in vivo toxicity. Ann Thorac Surg 79 (2005) 1522-1529
-
(2005)
Ann Thorac Surg
, vol.79
, pp. 1522-1529
-
-
Fürst, W.1
Banerjee, A.2
-
32
-
-
0034815918
-
Commercial fibrin sealants in surgical care
-
Spotnitz W.D. Commercial fibrin sealants in surgical care. Am J Surg 182 suppl 2 (2001) 8S-14S
-
(2001)
Am J Surg
, vol.182
, Issue.SUPPL. 2
-
-
Spotnitz, W.D.1
-
33
-
-
85047697608
-
Treatment of suture line bleeding with a novel synthetic surgical sealant in a canine iliac PTFE graft model
-
Hill A., Estridge T.D., Maroney M., et al. Treatment of suture line bleeding with a novel synthetic surgical sealant in a canine iliac PTFE graft model. J Biomed Mater Res 58 (2001) 308-312
-
(2001)
J Biomed Mater Res
, vol.58
, pp. 308-312
-
-
Hill, A.1
Estridge, T.D.2
Maroney, M.3
-
34
-
-
0033858145
-
Sutureless coronary artery bypass with biologic glued anastomoses: preliminary in vivo and in vitro results
-
Gundry S.R., Black K., and Izutani H. Sutureless coronary artery bypass with biologic glued anastomoses: preliminary in vivo and in vitro results. J Thorac Cardiovasc Surg 120 (2000) 473-477
-
(2000)
J Thorac Cardiovasc Surg
, vol.120
, pp. 473-477
-
-
Gundry, S.R.1
Black, K.2
Izutani, H.3
|