메뉴 건너뛰기




Volumn 15, Issue 1, 2009, Pages 49-53

Delayed insertion of blood culture bottles into automated continuously monitoring blood culture systems increases the time from blood sample collection to the detection of microorganisms in bacteremic patients

Author keywords

Bacteremia; Blood culture; Detection time

Indexed keywords

ACHROMOBACTER XYLOSOXIDANS; ACINETOBACTER; AEROMONAS; ARTICLE; BACILLUS; BACTEREMIA; BACTERIUM DETECTION; BACTEROIDES; BIFIDOBACTERIUM; BLOOD CULTURE; BLOOD SAMPLING; BURKHOLDERIA CEPACIA; CAMPYLOBACTER; CANDIDA; CITROBACTER; CLOSTRIDIUM PERFRINGENS; CORYNEBACTERIUM; CRYPTOCOCCUS NEOFORMANS; ENTEROBACTER; ENTEROCOCCUS; ESCHERICHIA COLI; EUBACTERIUM LIMOSUM; FUSOBACTERIUM VARIUM; GRAM POSITIVE BACTERIUM; KLEBSIELLA; LACTOBACILLUS; MICROORGANISM DETECTION; MORGANELLA; NONHUMAN; PANTOEA AGGLOMERANS; PEDIOCOCCUS; PORPHYROMONAS; PREVOTELLA LOESCHEII; PROPIONIBACTERIUM ACNES; PROTEUS MIRABILIS; PSEUDOMONAS; SALMONELLA; SERRATIA MARCESCENS; SPHINGOMONAS PAUCIMOBILIS; STAPHYLOCOCCUS; STENOTROPHOMONAS MALTOPHILIA; STREPTOCOCCUS;

EID: 62449323045     PISSN: 1341321X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10156-008-0664-6     Document Type: Article
Times cited : (23)

References (15)
  • 1
    • 0029941108 scopus 로고    scopus 로고
    • Clinical evaluation of the BacT/Alert and isolator aerobic blood culture systems
    • H.D. Engler G.A. Fahle V.J. Gill 1996 Clinical evaluation of the BacT/Alert and isolator aerobic blood culture systems Am J Clin Pathol 105 774 781
    • (1996) Am J Clin Pathol , vol.105 , pp. 774-781
    • Engler, H.D.1    Fahle, G.A.2    Gill, V.J.3
  • 2
    • 0032953466 scopus 로고    scopus 로고
    • Times to detection of bacteria and yeasts in BACTEC 9240 blood culture bottles
    • B.S. Reisner G.L. Woods 1999 Times to detection of bacteria and yeasts in BACTEC 9240 blood culture bottles J Clin Microbiol 37 2024 2026
    • (1999) J Clin Microbiol , vol.37 , pp. 2024-2026
    • Reisner, B.S.1    Woods, G.L.2
  • 3
    • 0029759347 scopus 로고    scopus 로고
    • Clinical importance of increased sensitivity of BacT/Alert FAN aerobic and anaerobic blood culture bottles
    • L.C. McDonald J. Fune L.B. Gaido M.P. Weinstein L.G. Reimer T.M. Flynn 1996 Clinical importance of increased sensitivity of BacT/Alert FAN aerobic and anaerobic blood culture bottles J Clin Microbiol 34 2180 2184
    • (1996) J Clin Microbiol , vol.34 , pp. 2180-2184
    • McDonald, L.C.1    Fune, J.2    Gaido, L.B.3    Weinstein, M.P.4    Reimer, L.G.5    Flynn, T.M.6
  • 4
    • 0033779706 scopus 로고    scopus 로고
    • Clinical comparison of nonvented aerobic BacT/Alert blood culture bottle and standard aerobic bottle for detection of microorganisms in blood
    • J.W. Snyder K.S. Benzing G.K. Munier G.D. Bostic P.S. Bozigar R. Hanna 2000 Clinical comparison of nonvented aerobic BacT/Alert blood culture bottle and standard aerobic bottle for detection of microorganisms in blood J Clin Microbiol 38 3864 3866
    • (2000) J Clin Microbiol , vol.38 , pp. 3864-3866
    • Snyder, J.W.1    Benzing, K.S.2    Munier, G.K.3    Bostic, G.D.4    Bozigar, P.S.5    Hanna, R.6
  • 5
    • 0028940908 scopus 로고
    • Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia
    • M.P. Weinstein S. Mirrett L.G. Reimer M.L. Wilson S. Smith-Elekes C.R. Chuard 1995 Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia J Clin Microbiol 33 978 981
    • (1995) J Clin Microbiol , vol.33 , pp. 978-981
    • Weinstein, M.P.1    Mirrett, S.2    Reimer, L.G.3    Wilson, M.L.4    Smith-Elekes, S.5    Chuard, C.R.6
  • 6
    • 0029154485 scopus 로고
    • Controlled evaluation of BacT/alert standard anaerobic and FAN anaerobic blood culture bottles for the detection of bacteremia and fungemia
    • M.L. Wilson M.P. Weinstein S. Mirrett L.G. Reimer R.J. Feldman C.R. Chuard 1995 Controlled evaluation of BacT/alert standard anaerobic and FAN anaerobic blood culture bottles for the detection of bacteremia and fungemia J Clin Microbiol 33 2265 2270
    • (1995) J Clin Microbiol , vol.33 , pp. 2265-2270
    • Wilson, M.L.1    Weinstein, M.P.2    Mirrett, S.3    Reimer, L.G.4    Feldman, R.J.5    Chuard, C.R.6
  • 7
    • 33644620821 scopus 로고    scopus 로고
    • Comparison of the effect of delayed entry into 2 different blood culture systems (BACTEC 9240 and BacT/ALERT 3D) on culture positivity
    • A. Akan E. YIldIz 2006 Comparison of the effect of delayed entry into 2 different blood culture systems (BACTEC 9240 and BacT/ALERT 3D) on culture positivity Diagn Microbiol Infect Dis 54 193 196
    • (2006) Diagn Microbiol Infect Dis , vol.54 , pp. 193-196
    • Akan, A.1    Yildiz, E.2
  • 8
    • 4544383984 scopus 로고    scopus 로고
    • Sensitivity of the BacT/ALERT FA-medium for detection of Pseudomonas aeruginosa in pre-incubated blood cultures and its temperature-dependence
    • I. Seegmüller U. Eschenbach K. Kamereck T. Miethke 2004 Sensitivity of the BacT/ALERT FA-medium for detection of Pseudomonas aeruginosa in pre-incubated blood cultures and its temperature-dependence J Med Microbiol 53 869 874
    • (2004) J Med Microbiol , vol.53 , pp. 869-874
    • Seegmüller, I.1    Eschenbach, U.2    Kamereck, K.3    Miethke, T.4
  • 9
    • 13744255992 scopus 로고    scopus 로고
    • Effect of delay of blood cultures on positive detection by automated blood culture systems (in Japanese)
    • I. Kobayashi M. Yamamoto M. Hasegawa Y. Sato U. Uchino A. Kaneko 2004 Effect of delay of blood cultures on positive detection by automated blood culture systems (in Japanese) Kansenshogaku Zasshi 78 959 966
    • (2004) Kansenshogaku Zasshi , vol.78 , pp. 959-966
    • Kobayashi, I.1    Yamamoto, M.2    Hasegawa, M.3    Sato, Y.4    Uchino, U.5    Kaneko, A.6
  • 10
    • 33645907524 scopus 로고    scopus 로고
    • Effects of delayed-entry conditions on the recovery and detection of microorganisms from BacT/ALERT and BACTEC blood culture bottles
    • R.L. Sautter A.R. Bills D.L. Lang G. Ruschell B.J. Heiter P.P. Bourbeau 2006 Effects of delayed-entry conditions on the recovery and detection of microorganisms from BacT/ALERT and BACTEC blood culture bottles J Clin Microbiol 44 1245 1249
    • (2006) J Clin Microbiol , vol.44 , pp. 1245-1249
    • Sautter, R.L.1    Bills, A.R.2    Lang, D.L.3    Ruschell, G.4    Heiter, B.J.5    Bourbeau, P.P.6
  • 11
    • 62449111543 scopus 로고    scopus 로고
    • Effect of delayed vial entry on recovery of blood culture isolates in automated blood culture systems (in Japanese)
    • S. Kawakami Y. Ono Y. Miyazawa 2002 Effect of delayed vial entry on recovery of blood culture isolates in automated blood culture systems (in Japanese) JJCM 12 86 92
    • (2002) JJCM , vol.12 , pp. 86-92
    • Kawakami, S.1    Ono, Y.2    Miyazawa, Y.3
  • 12
  • 13
    • 15244356278 scopus 로고    scopus 로고
    • Blood culture Gram-stain and clinical categorization based empirical antimicrobial therapy of bloodstream infection
    • T. Hautala H. Syrjala V. Lehtinen H. Kauma J. Kauppila P. Kujala 2005 Blood culture Gram-stain and clinical categorization based empirical antimicrobial therapy of bloodstream infection Int J Antimicrob Agents 25 329 333
    • (2005) Int J Antimicrob Agents , vol.25 , pp. 329-333
    • Hautala, T.1    Syrjala, H.2    Lehtinen, V.3    Kauma, H.4    Kauppila, J.5    Kujala, P.6
  • 14
    • 0035015998 scopus 로고    scopus 로고
    • Controlled comparison of original vented aerobic FAN medium with new nonvented BacT/ALERT FA medium for culturing blood
    • S. Mirrett R.J. Everts L.B. Reller 2001 Controlled comparison of original vented aerobic FAN medium with new nonvented BacT/ALERT FA medium for culturing blood J Clin Microbiol 39 2098 2101
    • (2001) J Clin Microbiol , vol.39 , pp. 2098-2101
    • Mirrett, S.1    Everts, R.J.2    Reller, L.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.