메뉴 건너뛰기




Volumn 13, Issue 6, 2008, Pages

Pinhole shifting lifetime imaging microscopy

Author keywords

Confocal microscope; Europium; Lifetime imaging; Luminescence; Twophoton excitation

Indexed keywords

BIOLOGICAL PHENOMENA; CONFOCAL MICROSCOPES; DELAYED LUMINESCENCE; FLUOROPHORE CONCENTRATION; INDEPENDENT MEASUREMENT; LASER SCANNING; LIFETIME IMAGING; LUMINESCENCE INTENSITY; ORTHOGONAL DIRECTIONS; PROOF OF PRINCIPLES; TIME RESOLVED IMAGING; TWO-PHOTON EXCITATIONS;

EID: 62449303768     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.3027503     Document Type: Article
Times cited : (16)

References (28)
  • 1
    • 33645456918 scopus 로고    scopus 로고
    • Multiphoton fluorescence lifetime contrast in deep tissue imaging: Prospects in redox imaging and disease diagnosis
    • V. K. Ramanujan, J.-H. Zhang, E. Biener, and B. Herman, "Multiphoton fluorescence lifetime contrast in deep tissue imaging: prospects in redox imaging and disease diagnosis", J. Biomed. Opt. 10, 1-11 (2005).
    • (2005) J. Biomed. Opt. , vol.10 , pp. 1-11
    • Ramanujan, V.K.1    Zhang, J.-H.2    Biener, E.3    Herman, B.4
  • 2
    • 33750880053 scopus 로고    scopus 로고
    • A superfusion system to study border zones in confluent cultures of neonatal rat heart cells
    • C. J. Hyatt, J. J. Lemasters, B. J. Muller-Borer, T. A. Johnson, and W. E. Cascio, "A superfusion system to study border zones in confluent cultures of neonatal rat heart cells", Am. J. Physiol. 274, H2001-H2008 (1998).
    • (1998) Am. J. Physiol. , vol.274
    • Hyatt, C.J.1    Lemasters, J.J.2    Muller-Borer, B.J.3    Johnson, T.A.4    Cascio, W.E.5
  • 3
    • 24944581712 scopus 로고    scopus 로고
    • 2+] in cellular organelles by SEER, shifted excitation and emission ratioing of fluorescence
    • DOI 10.1113/jphysiol.2005.087973
    • B. S. Launikonis, J. Zhou, L. Royer, T. R. Shannon, G. Brum, and E. Ríos, "Confocal imaging of [Ca2 +] in cellular organelles by SEER, shifted excitation and emission ratioing of fluorescence", J. Physiology 567, 523-543 (2005). (Pubitemid 41301049)
    • (2005) Journal of Physiology , vol.567 , Issue.2 , pp. 523-543
    • Launikonis, B.S.1    Zhou, J.2    Royer, L.3    Shannon, T.R.4    Brum, G.5    Rios, E.6
  • 6
    • 0000678524 scopus 로고    scopus 로고
    • Time-resolved fluorescence lifetime imaging microscopy using a picosecond pulsed tunable dye laser system
    • A. Periasamy, P. Wodnicki, X. F. Wang, S. Kwon, G. W. Gordon, and B. Herman, "Time-resolved fluorescence lifetime imaging microscopy using a picosecond tunable dye laser system", Rev. Sci. Instrum. 67, 3722-3731 (1996). (Pubitemid 126569402)
    • (1996) Review of Scientific Instruments , vol.67 , Issue.10 , pp. 3722-3731
    • Periasamy, A.1    Wodnicki, P.2    Wang, X.F.3    Kwon, S.4    Gordon, G.W.5    Herman, B.6
  • 7
    • 0002804044 scopus 로고
    • Fluorescence lifetime imaging, a new tool in confocal microscopy
    • 2nd ed., J. B. Pawley, Ed., Plenum Press, New York
    • A. Draaijer, R. Sanders, and H. C. Gerritsen, "Fluorescence lifetime imaging, a new tool in confocal microscopy", in Handbook of Biological Confocal Microscopy, 2nd ed., J. B. Pawley, Ed., pp. 491-505, Plenum Press, New York (1995).
    • (1995) Handbook of Biological Confocal Microscopy , pp. 491-505
    • Draaijer, A.1    Sanders, R.2    Gerritsen, H.C.3
  • 10
    • 0036016786 scopus 로고    scopus 로고
    • Fluorescence lifetime imaging in scanning microscopes: Acquisition speed, photon economy and lifetime resolution
    • DOI 10.1046/j.1365-2818.2002.01031.x
    • H. C. Gerritsen, M. A. H. Asselbergs, A. V. Agronskaia, and W. G. Van Sark, "Fluorescence lifetime imaging in scanning microscopes: acquisition speed, photon economy and lifetime resolution", J. Microsc. 206, 218-224 (2002). (Pubitemid 34639419)
    • (2002) Journal of Microscopy , vol.206 , Issue.3 , pp. 218-224
    • Gerritsen, H.C.1    Asselbergs, M.A.H.2    Agronskaia, A.V.3    Van Sark, W.G.J.H.M.4
  • 12
    • 33751544960 scopus 로고
    • Lifetime-sensitive fluorescence imaging using an rf phase sensitive camera
    • J. Lakowicz and K. Berndt, "Lifetime-sensitive fluorescence imaging using an rf phase sensitive camera", Rev. Sci. Instrum. 62, 1727-1734 (1991).
    • (1991) Rev. Sci. Instrum. , vol.62 , pp. 1727-1734
    • Lakowicz, J.1    Berndt, K.2
  • 13
    • 0020997959 scopus 로고
    • A continuosly variable frequency cross-correlation phase fluorometer with picosecond resolution
    • E. Gratton and M. Limkeman, "A continuosly variable frequency cross-correlation phase fluorometer with picosecond resolution", Biophys. J. 44, 315-324 (1983).
    • (1983) Biophys. J. , vol.44 , pp. 315-324
    • Gratton, E.1    Limkeman, M.2
  • 14
    • 0141644218 scopus 로고    scopus 로고
    • Fluorescence lifetime imaging for two-photon microscope: Time-domain and frequency-domain methods
    • E. Gratton, S. Breusegmen, J. Sutin, Q. Ruan, and N. Barry, "Fluorescence lifetime imaging for two-photon microscope: time-domain and frequency-domain methods", J. Biomed. Opt. 8, 381-390 (2003).
    • (2003) J. Biomed. Opt. , vol.8 , pp. 381-390
    • Gratton, E.1    Breusegmen, S.2    Sutin, J.3    Ruan, Q.4    Barry, N.5
  • 15
    • 51649093566 scopus 로고    scopus 로고
    • Rapid frequency-domain FLIM spinning disk confocal microscope: Lifetime resolution, image improvement and wavelet analysis
    • C. Buranachai, D. Kamiyama, A. Chiba, B. D. Williams, and R. M. Clegg, "Rapid frequency-domain FLIM spinning disk confocal microscope: lifetime resolution, image improvement and wavelet analysis", J. Fluoresc. 18(5), 929-942 (2008).
    • (2008) J. Fluoresc. , vol.18 , Issue.5 , pp. 929-942
    • Buranachai, C.1    Kamiyama, D.2    Chiba, A.3    Williams, B.D.4    Clegg, R.M.5
  • 17
    • 0043201291 scopus 로고    scopus 로고
    • Lifetime modulation of a ruthenium-based dye in living cells: The potential for oxygen sensing
    • W. Zhong, P. Urayama, and M.-A. Mycek, "Lifetime modulation of a ruthenium-based dye in living cells: the potential for oxygen sensing", J. Phys. D 36, 1689-1695 (2003).
    • (2003) J. Phys. D , vol.36 , pp. 1689-1695
    • Zhong, W.1    Urayama, P.2    Mycek, M.-A.3
  • 19
    • 0036049484 scopus 로고    scopus 로고
    • High resolution detection of fluorescently labeled microorganisms in environmental samples using time-resolved fluorescence microscopy
    • R. Connally, D. Veal, and J. Piper, "High resolution detection of fluorescently labeled microorganisms in environmental samples using time-resolved fluorescence microscopy", FEMS Microbiol. Ecol. 41, 2390245 (2002).
    • (2002) FEMS Microbiol. Ecol. , vol.41 , pp. 2390245
    • Connally, R.1    Veal, D.2    Piper, J.3
  • 20
    • 4444274845 scopus 로고    scopus 로고
    • Flash lamp-excited time-resolved fluorescence microscope suppresses autofluorescence in water concentrates to deliver an 11-fold increase in signal-to-noise ratio
    • R. Connally, D. Veal, and J. Piper, "Flash lamp-excited time-resolved fluorescence microscope suppresses autofluorescence in water concentrates to deliver an 11-fold increase in signal-to-noise ratio", J. Biomed. Opt. 9, 725-734 (2004).
    • (2004) J. Biomed. Opt. , vol.9 , pp. 725-734
    • Connally, R.1    Veal, D.2    Piper, J.3
  • 21
    • 7544240208 scopus 로고    scopus 로고
    • Time-resolved fluorescence microscopy using an improved europium chelate BHHST for the in situ detection of Cryptosporidium and Giardia
    • DOI 10.1002/jemt.20087
    • R. Connally, D. Veal, and J. Piper, "Time-resolved fluorescence microscopy using an improved europium chelate BHHST for the in-situ detection of cryptosporidium and giardia", Microsc. Res. Tech. 64, 312-322 (2004). (Pubitemid 39453320)
    • (2004) Microscopy Research and Technique , vol.64 , Issue.4 , pp. 312-322
    • Connally, R.1    Veal, D.2    Piper, J.3
  • 22
    • 0002700296 scopus 로고
    • An error analysis of the rapid lifetime determination method for the evaluation of single exponential decays
    • R. M. Ballew and J. N. Demas, "An error analysis of the rapid lifetime determination method for the evaluation of single exponential decays", Anal. Chem. 61, 30-33 (1989).
    • (1989) Anal. Chem. , vol.61 , pp. 30-33
    • Ballew, R.M.1    Demas, J.N.2
  • 23
    • 0033104283 scopus 로고    scopus 로고
    • Error analysis of the rapid lifetime determination method for double-exponential decays and new windowing schemes
    • K. K. Sharman, A. Periasamy, H. Ashworth, J. N. Demas, and N. H. Snow, "Error analysis of the rapid lifetime determination method for double-exponential decays and new windowing schemes", Anal. Chem. 71, 947-952 (1999).
    • (1999) Anal. Chem. , vol.71 , pp. 947-952
    • Sharman, K.K.1    Periasamy, A.2    Ashworth, H.3    Demas, J.N.4    Snow, N.H.5
  • 25
    • 0035359486 scopus 로고    scopus 로고
    • Multiple time-gate module for fluorescence lifetime imaging
    • DOI 10.1366/0003702011952587
    • C. J. D. Grauw and H. C. Gerritsen, "Multiple time-gated module for fluorescence lifetime imaging", Appl. Spectrosc. 55, 670-678 (2001). (Pubitemid 32672273)
    • (2001) Applied Spectroscopy , vol.55 , Issue.6 , pp. 670-678
    • De Grauw, C.J.1    Gerritsen, H.C.2
  • 27
    • 34147196585 scopus 로고    scopus 로고
    • Combination of a spinning disc confocal unit with frequency-domain fluorescence lifetime imaging microscopy
    • DOI 10.1002/cyto.a.20379
    • E. B. Van Munster, J. Goedhart, G. J. Kremers, E. M. M. Manders, and T. W. J. Gadella Jr., "Combination of a spinning disc confocal unit with frequency-domain fluorescence lifetime imaging microscopy", Cytometry, Part A 71 A, 207-214 (2007). (Pubitemid 46581282)
    • (2007) Cytometry Part A , vol.71 , Issue.4 , pp. 207-214
    • Van Munster, E.B.1    Goedhart, J.2    Kremers, G.J.3    Manders, E.M.M.4    Gadella Jr., T.W.J.5
  • 28
    • 0141509840 scopus 로고    scopus 로고
    • Quantitative imaging of protein-protein interactions by multiphoton fluorescence lifetime imaging microscopy using a streak camera
    • R. Krishnan, A. Masuda, V. Centonze, and B. Herman, "Quantitative imaging of protein-protein interactions by multiphoton fluorescence lifetime imaging microscopy using a streak camera", J. Biomed. Opt. 8, 362-367 (2003).
    • (2003) J. Biomed. Opt. , vol.8 , pp. 362-367
    • Krishnan, R.1    Masuda, A.2    Centonze, V.3    Herman, B.4