메뉴 건너뛰기




Volumn 35, Issue 5, 2009, Pages 906-911

Intraocular lens calculation in extreme myopia

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CALCULATION; EYE AXIS LENGTH; LENS IMPLANT; LENS POWER; MYOPIA; PRIORITY JOURNAL; REFRACTION ERROR;

EID: 62349107069     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2008.12.035     Document Type: Article
Times cited : (83)

References (10)
  • 1
    • 0014983938 scopus 로고
    • Axial length measurements and fundus changes of the myopic eye
    • Curtin B.J., and Karlin D.B. Axial length measurements and fundus changes of the myopic eye. Am J Ophthalmol 71 (1971) 42-53
    • (1971) Am J Ophthalmol , vol.71 , pp. 42-53
    • Curtin, B.J.1    Karlin, D.B.2
  • 2
    • 64849116180 scopus 로고    scopus 로고
    • Haigis W. IOL calculation in long and short eyes. In: Garg A, Hoyos JE, Dementiev D, eds, Mastering the Techniques of IOL Power Calculations. New Delhi, India, Jaypee Brothers, 2005; 75-85. Also in: Garg A, Lin JT, eds, Mastering Intraocular Lenses (IOLs); Principles, Techniques and Innovations. New Delhi, India, Jaypee Brothers, 2007; 92-99
    • Haigis W. IOL calculation in long and short eyes. In: Garg A, Hoyos JE, Dementiev D, eds, Mastering the Techniques of IOL Power Calculations. New Delhi, India, Jaypee Brothers, 2005; 75-85. Also in: Garg A, Lin JT, eds, Mastering Intraocular Lenses (IOLs); Principles, Techniques and Innovations. New Delhi, India, Jaypee Brothers, 2007; 92-99
  • 3
    • 0007834155 scopus 로고    scopus 로고
    • Einfluß der Optikform auf die individuelle Anpassung von Linsenkonstanten zur IOL-Berechnung
    • Rochels R., Duncker G., and Hartmann C. (Eds), Springer-Verlag, Berlin
    • Haigis W. Einfluß der Optikform auf die individuelle Anpassung von Linsenkonstanten zur IOL-Berechnung. In: Rochels R., Duncker G., and Hartmann C. (Eds). 9. Kongress der Deutschprachigen Gesellschaft für Intraokularlinsen Implantation, Kiel 1995 (1996), Springer-Verlag, Berlin 183-189
    • (1996) 9. Kongress der Deutschprachigen Gesellschaft für Intraokularlinsen Implantation, Kiel 1995 , pp. 183-189
    • Haigis, W.1
  • 4
    • 0033805274 scopus 로고    scopus 로고
    • Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis
    • Haigis W., Lege B., Miller N., and Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol 238 (2000) 765-773
    • (2000) Graefes Arch Clin Exp Ophthalmol , vol.238 , pp. 765-773
    • Haigis, W.1    Lege, B.2    Miller, N.3    Schneider, B.4
  • 5
    • 0030817812 scopus 로고    scopus 로고
    • Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculation
    • Holladay J.T. Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculation. J Cataract Refract Surg 23 (1997) 1356-1370
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1356-1370
    • Holladay, J.T.1
  • 6
    • 60849090212 scopus 로고    scopus 로고
    • Matrix-optical representation of currently used IOL power formulas
    • In press
    • Haigis W. Matrix-optical representation of currently used IOL power formulas. In press. J Refract Surg (2009)
    • (2009) J Refract Surg
    • Haigis, W.1
  • 7
    • 0006282932 scopus 로고
    • Strahldurchrechnung in Gaußscher Optik zur Beschreibung des Linsensystems Brille-Kontaktlinse-Hornhaut-Augenlinse (IOL)
    • Schott K., Jakobi K.W., and Freyler H. (Eds), Springer-Verlag, Berlin
    • Haigis W. Strahldurchrechnung in Gaußscher Optik zur Beschreibung des Linsensystems Brille-Kontaktlinse-Hornhaut-Augenlinse (IOL). In: Schott K., Jakobi K.W., and Freyler H. (Eds). 4. Kongreß der Deutschen Gesellschaft für Intraokularlinsen Implantation, Essen 1990 (1991), Springer-Verlag, Berlin 233-246
    • (1991) 4. Kongreß der Deutschen Gesellschaft für Intraokularlinsen Implantation, Essen 1990 , pp. 233-246
    • Haigis, W.1
  • 9
    • 77349095607 scopus 로고    scopus 로고
    • User Group for Laser Interference Biometry, Available at:, Accessed December 31, 2008
    • User Group for Laser Interference Biometry. Optimized constants for the Zeiss IOLMaster. Available at: http://www.augenklinik.uni-wuerzburg.de/eulib/. Accessed December 31, 2008
    • Optimized constants for the Zeiss IOLMaster
  • 10
    • 2342604390 scopus 로고    scopus 로고
    • Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power
    • Norrby S. Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power. J Cataract Refract Surg 30 (2004) 1000-1005
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1000-1005
    • Norrby, S.1