메뉴 건너뛰기




Volumn , Issue , 2008, Pages 3479-3482

Detection of obstructive sleep apnea in children using decreases in the amplitude fluctuations of PPG signal and HRV

Author keywords

[No Author keywords available]

Indexed keywords

DISCRIMINANT ANALYSIS; WIGNER-VILLE DISTRIBUTION;

EID: 61849185749     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iembs.2008.4649955     Document Type: Conference Paper
Times cited : (2)

References (13)
  • 1
    • 1142306684 scopus 로고    scopus 로고
    • Clinical practice guideline: Diagnosis and management of childhood obstructive sleep apnea syndrome
    • American Academy of Pediatrics
    • American Academy of Pediatrics, "Clinical practice guideline: Diagnosis and management of childhood obstructive sleep apnea syndrome," Pediatrics, vol. 109, pp. 704-712, 2002.
    • (2002) Pediatrics , vol.109 , pp. 704-712
  • 4
    • 52049090570 scopus 로고    scopus 로고
    • Detection of decreases in the amplitude fluctuation of pulse photoplethysmography signal as indication of obstructive sleep apnea syndrome in children
    • doi:10.1016/j.bspc.2007.12.002
    • E. Gil, J. M. Vergara, and P. Laguna, "Detection of decreases in the amplitude fluctuation of pulse photoplethysmography signal as indication of obstructive sleep apnea syndrome in children," Biomed. Signal Process. Control, 2008, doi:10.1016/j.bspc.2007.12.002.
    • Biomed. Signal Process. Control , vol.2008
    • Gil, E.1    Vergara, J.M.2    Laguna, P.3
  • 5
    • 0037662724 scopus 로고    scopus 로고
    • An automatic ambulatory device for detection of aasm defined arousals from sleep: The wp100
    • G. Pillar, A. Bar, M. Betito, R. P. Schnall, I. Dvir, J. Sheffy, and P. Lavie, "An automatic ambulatory device for detection of aasm defined arousals from sleep: the wp100," Sleep Medicine, vol. 4, pp. 207-212, 2003.
    • (2003) Sleep Medicine , vol.4 , pp. 207-212
    • Pillar, G.1    Bar, A.2    Betito, M.3    Schnall, R.P.4    Dvir, I.5    Sheffy, J.6    Lavie, P.7
  • 6
    • 34247467602 scopus 로고    scopus 로고
    • Photoplethysmography and its application in clinical physiological measurement
    • doi:10.1088/0967-3334/28/3/R01
    • J. Allen, "Photoplethysmography and its application in clinical physiological measurement," Physiol. Meas., vol. 28, 2007, doi:10.1088/0967-3334/28/3/R01.
    • Physiol. Meas , vol.28 , pp. 2007
    • Allen, J.1
  • 8
    • 0030068472 scopus 로고    scopus 로고
    • Standards and indications for cardiopulmonary sleep studies in children
    • American Thoracic Society
    • American Thoracic Society, "Standards and indications for cardiopulmonary sleep studies in children," Am. J. Respir. Crit. Care Med., vol. 153, pp. 866-878, 1996.
    • (1996) Am. J. Respir. Crit. Care Med , vol.153 , pp. 866-878
  • 9
    • 0017730850 scopus 로고
    • Digital filters for ecg signals
    • D. Mortara, "Digital filters for ecg signals," in IEEE Computer Society Press, 1977, pp. 511-514.
    • (1977) IEEE Computer Society Press , pp. 511-514
    • Mortara, D.1
  • 11
    • 0037342571 scopus 로고    scopus 로고
    • Analysis of heart rate variability in the presence of ectopic beats using the heart timing signal
    • J. Mateo and P. Laguna, "Analysis of heart rate variability in the presence of ectopic beats using the heart timing signal," IEEE Transactions on Biomedical Engineering, vol. 50, no. 3, pp. 334-343, 2003.
    • (2003) IEEE Transactions on Biomedical Engineering , vol.50 , Issue.3 , pp. 334-343
    • Mateo, J.1    Laguna, P.2
  • 12
    • 0028789504 scopus 로고
    • Use of the pulse time as a measure of inspiratoy effort in patients with obstructive sleep apnea
    • D. Pitson, A. Sandell, R. van den Hout, and J. Stradling, "Use of the pulse time as a measure of inspiratoy effort in patients with obstructive sleep apnea," Eur. Respir. J., vol. 8, pp. 1669-1674, 1995.
    • (1995) Eur. Respir. J , vol.8 , pp. 1669-1674
    • Pitson, D.1    Sandell, A.2    van den Hout, R.3    Stradling, J.4
  • 13
    • 0036813658 scopus 로고    scopus 로고
    • Age-realted changes in peripheral pulse timing characteristics at the ears, thumbs and toes
    • J. Allen and A. Murray, "Age-realted changes in peripheral pulse timing characteristics at the ears, thumbs and toes," Journal of Human Hypertension, vol. 16, pp. 711-717, 2002.
    • (2002) Journal of Human Hypertension , vol.16 , pp. 711-717
    • Allen, J.1    Murray, A.2