메뉴 건너뛰기




Volumn , Issue , 2008, Pages 715-718

An electronic implant for hydrocephalus therapy assistance

Author keywords

[No Author keywords available]

Indexed keywords

ENGINEERING; INDUSTRIAL ENGINEERING;

EID: 61849164428     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iembs.2008.4649252     Document Type: Conference Paper
Times cited : (4)

References (10)
  • 2
    • 0030984266 scopus 로고    scopus 로고
    • A simple mathematical model of the interaction between intracranial pressure and cerebral hemodynamics
    • M. Ursino, C. A. Lodi, A simple mathematical model of the interaction between intracranial pressure and cerebral hemodynamics. J Appl Physiol 82, pp. 1256-1269, 1997.
    • (1997) J Appl Physiol , vol.82 , pp. 1256-1269
    • Ursino, M.1    Lodi, C.A.2
  • 3
    • 33846905233 scopus 로고    scopus 로고
    • M. Walter, S. Jetzki, S. Leonhardt, A Model for Intracranial Hydrodynamics. Conf Proc IEEE Eng Med Biol Soc. 2005, 6 pp. 5603-6, 2005.
    • M. Walter, S. Jetzki, S. Leonhardt, A Model for Intracranial Hydrodynamics. Conf Proc IEEE Eng Med Biol Soc. 2005, 6 pp. 5603-6, 2005.
  • 4
    • 28544435010 scopus 로고    scopus 로고
    • Analysis of intracranial pressure during and after the infusion test in patients with communicating hydrocephalus
    • H. Juniewicz, M. Kasprowicz, M. Czosnyka, Z. Czosnyka, S. Gizewski, M. Dzik, J.D. Pickard, Analysis of intracranial pressure during and after the infusion test in patients with communicating hydrocephalus. Physiol. Meas. 26, pp. 1039-1048, 2005.
    • (2005) Physiol. Meas , vol.26 , pp. 1039-1048
    • Juniewicz, H.1    Kasprowicz, M.2    Czosnyka, M.3    Czosnyka, Z.4    Gizewski, S.5    Dzik, M.6    Pickard, J.D.7
  • 8
    • 34547434637 scopus 로고    scopus 로고
    • Continuous intracranial pressure monitoring via the shunt reservoir to assess suspected shunt malfunction in adults with hydrocephalus
    • R.G. Geocadin, P.N. Varelas, D. Rigamonti, M.A. Williams, Continuous intracranial pressure monitoring via the shunt reservoir to assess suspected shunt malfunction in adults with hydrocephalus. Neurosurg Focus 22 (4), E10, 2007.
    • (2007) Neurosurg Focus , vol.22 , Issue.4
    • Geocadin, R.G.1    Varelas, P.N.2    Rigamonti, D.3    Williams, M.A.4
  • 9
    • 8744295791 scopus 로고    scopus 로고
    • G. Citero, I. Piper, M. Cormio, D. Galli, S. Cazzaniga, P. Enblad, P. Nilsson, C. Contant, I. Chambers on behalf of the BrainIT Group, Bench test assessment of the new Raumedic Neurovent-P ICP sensor: a technical report by BrainIT group. Acta Neurochir (Wien) Nov; 146 (11), pp. 1221-6, 2004.
    • G. Citero, I. Piper, M. Cormio, D. Galli, S. Cazzaniga, P. Enblad, P. Nilsson, C. Contant, I. Chambers on behalf of the BrainIT Group, Bench test assessment of the new Raumedic Neurovent-P ICP sensor: a technical report by BrainIT group. Acta Neurochir (Wien) Nov; 146 (11), pp. 1221-6, 2004.
  • 10
    • 61849131498 scopus 로고    scopus 로고
    • http://www.sophysa.com/en/?id=C3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.