메뉴 건너뛰기




Volumn 8, Issue 3, 2009, Pages 373-376

Brief communication - Cardiopulmonary bypass Retrograde autologous priming and allogeneic blood transfusions: A meta-analysis

Author keywords

Blood conservation; Blood transfusions; Cardiopulmonary bypass; On pump

Indexed keywords

ARTICLE; BLOOD AUTOTRANSFUSION; CARDIOPULMONARY BYPASS; CLINICAL TRIAL; CORONARY ARTERY BYPASS GRAFT; ERYTHROCYTE TRANSFUSION; HUMAN; INTRAOPERATIVE PERIOD; META ANALYSIS; PRIORITY JOURNAL; SYSTEMATIC REVIEW; BLEEDING; BLOOD TRANSFUSION; EVIDENCE BASED MEDICINE; METHODOLOGY; POSTOPERATIVE HEMORRHAGE; RANDOMIZED CONTROLLED TRIAL; REVIEW;

EID: 61849110259     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2008.195354     Document Type: Article
Times cited : (48)

References (9)
  • 4
    • 0036263548 scopus 로고    scopus 로고
    • Retrograde autologous priming of the cardiopulmonary bypass circuit reduces blood transfusion after coronary artery surgery
    • Balachandran S, Cross MH, Karthikeyan S, Mulpur A, Hansbro SD, Hobson P. Retrograde autologous priming of the cardiopulmonary bypass circuit reduces blood transfusion after coronary artery surgery. Ann Thorac Surg 2002;73:1912-1918.
    • (2002) Ann Thorac Surg , vol.73 , pp. 1912-1918
    • Balachandran, S.1    Cross, M.H.2    Karthikeyan, S.3    Mulpur, A.4    Hansbro, S.D.5    Hobson, P.6
  • 6
    • 14544305501 scopus 로고    scopus 로고
    • Prospective study on cardiopulmonary bypass prime reduction and its effects on intraoperative blood product and hemoconcentrator use
    • Sobieski MA, Slaughter MS, Hart DE, Pappas PS, Tatooles AJ. Prospective study on cardiopulmonary bypass prime reduction and its effects on intraoperative blood product and hemoconcentrator use. Perfusion 2005;20:31-37.
    • (2005) Perfusion , vol.20 , pp. 31-37
    • Sobieski, M.A.1    Slaughter, M.S.2    Hart, D.E.3    Pappas, P.S.4    Tatooles, A.J.5
  • 8
    • 1942501214 scopus 로고    scopus 로고
    • The failure of retrograde autologous priming of the cardiopulmonary bypass circuit to reduce blood use after cardiac surgical procedures
    • Murphy GS, Szokol JW, Nitsun M, Alspach DA, Avarum MJ, Vender JS, Votapka TV, Rosengart TK. The failure of retrograde autologous priming of the cardiopulmonary bypass circuit to reduce blood use after cardiac surgical procedures. Anesth Analg 2004;98:1201-1207.
    • (2004) Anesth Analg , vol.98 , pp. 1201-1207
    • Murphy, G.S.1    Szokol, J.W.2    Nitsun, M.3    Alspach, D.A.4    Avarum, M.J.5    Vender, J.S.6    Votapka, T.V.7    Rosengart, T.K.8
  • 9
    • 61849097589 scopus 로고    scopus 로고
    • Basha J, Dewitt RG, Cable D, Jones GP. Transfusions and their costs: managing patients needs and hospitals economics. Internet J Emerg Intens Care Med 2006;9.
    • Basha J, Dewitt RG, Cable D, Jones GP. Transfusions and their costs: managing patients needs and hospitals economics. Internet J Emerg Intens Care Med 2006;9.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.