메뉴 건너뛰기




Volumn , Issue , 2008, Pages 1250-1253

Radiation characteristics of ingested wireless device at frequencies from 430 MHz to 3 GHz

Author keywords

[No Author keywords available]

Indexed keywords

FINITE DIFFERENCE TIME DOMAIN METHOD; METHOD OF MOMENTS; RADIATION EFFECTS;

EID: 61849087771     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (8)

References (20)
  • 1
    • 61849109589 scopus 로고    scopus 로고
    • IEEE Std 1528, IEEE recommended practice for determining the peak spatial-average specific absorption rate (SAR) in the human head from wireless communications devices: measurement techniques IEEE, 2003.
    • IEEE Std 1528, IEEE recommended practice for determining the peak spatial-average specific absorption rate (SAR) in the human head from wireless communications devices: measurement techniques IEEE, 2003.
  • 2
    • 0037035398 scopus 로고    scopus 로고
    • Some present problems and a proposed experimental phantom for SAR compliance testing of cellular telephones at 835 and 1900 MHz
    • O.P. Gandhi, and G. Kang, "Some present problems and a proposed experimental phantom for SAR compliance testing of cellular telephones at 835 and 1900 MHz," Physics in Medicine and Biology, vol. 47, 2002, pp. 1501-1518.
    • (2002) Physics in Medicine and Biology , vol.47 , pp. 1501-1518
    • Gandhi, O.P.1    Kang, G.2
  • 3
    • 0942288055 scopus 로고    scopus 로고
    • Comparison of FDTD-calculated specific absorption rate in adults and children when using a mobile phone at 900 and 1800 MHz
    • M. Martinez-Burdalo, A. Martin, M. Anguiano, R. Villar, "Comparison of FDTD-calculated specific absorption rate in adults and children when using a mobile phone at 900 and 1800 MHz," Physics in Medicine and Biology 2004, 49(2): 345-354.
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.2 , pp. 345-354
    • Martinez-Burdalo, M.1    Martin, A.2    Anguiano, M.3    Villar, R.4
  • 5
    • 0034713363 scopus 로고    scopus 로고
    • Wireless capsule endoscopy
    • G. Iddan, G. Meron, A. Glukhovsky et al., "Wireless capsule endoscopy," Nature, vol. 405, 2000, pp. 417-420.
    • (2000) Nature , vol.405 , pp. 417-420
    • Iddan, G.1    Meron, G.2    Glukhovsky, A.3
  • 6
    • 33748545568 scopus 로고    scopus 로고
    • Investigation of RF transmission properties of human tissues
    • D. Werber, A. Schwentner, and E.M. Biebl, "Investigation of RF transmission properties of human tissues," Advance in Radio Science, vol. 4, 2006, pp. 357-360.
    • (2006) Advance in Radio Science , vol.4 , pp. 357-360
    • Werber, D.1    Schwentner, A.2    Biebl, E.M.3
  • 7
    • 33751360637 scopus 로고    scopus 로고
    • Implanted antennas in medical wireless communications
    • R.S. Yahya, J.H. Kim, "Implanted antennas in medical wireless communications," Synthesis Lectures on Antennas, vol. 1, no. 1, pp. 1-82, 2006.
    • (2006) Synthesis Lectures on Antennas , vol.1 , Issue.1 , pp. 1-82
    • Yahya, R.S.1    Kim, J.H.2
  • 9
    • 0021913358 scopus 로고
    • Specific absorption rate in rats exposed to 2,450-MHz microwaves under seven exposure conditions
    • C.K. Chou, A.W. Guy, J.A. McDougall, and H. Lai, "Specific absorption rate in rats exposed to 2,450-MHz microwaves under seven exposure conditions," Bioelectromagnetics, vol. 6, 1985, pp. 73-88.
    • (1985) Bioelectromagnetics , vol.6 , pp. 73-88
    • Chou, C.K.1    Guy, A.W.2    McDougall, J.A.3    Lai, H.4
  • 10
    • 0034576886 scopus 로고    scopus 로고
    • The development of the swallowable video capsule (M2A)
    • December
    • G.D. Meron, "The development of the swallowable video capsule (M2A)," Gastrointestinal Endoscopy, vol. 52, December 2000, pp. 817-819.
    • (2000) Gastrointestinal Endoscopy , vol.52 , pp. 817-819
    • Meron, G.D.1
  • 12
    • 33750916342 scopus 로고    scopus 로고
    • Small spiral antenna for wideband capsule endoscope system
    • 9th November
    • S.I. Kwak, K. Chang and Y.J. Yoon, "Small spiral antenna for wideband capsule endoscope system," Electronics Letters, 9th November 2006, 42(23): 1328-1329.
    • (2006) Electronics Letters , vol.42 , Issue.23 , pp. 1328-1329
    • Kwak, S.I.1    Chang, K.2    Yoon, Y.J.3
  • 13
    • 33747858738 scopus 로고    scopus 로고
    • A 2.4 GHz low power ASK transmitter for wireless capsule endoscope applications
    • S.G. Han, B.Y. Chi, and Z.H. Wang, "A 2.4 GHz low power ASK transmitter for wireless capsule endoscope applications," Chinese Journal of Semiconductors, 27 (6): 988-993, 2006.
    • (2006) Chinese Journal of Semiconductors , vol.27 , Issue.6 , pp. 988-993
    • Han, S.G.1    Chi, B.Y.2    Wang, Z.H.3
  • 14
    • 0142028048 scopus 로고    scopus 로고
    • Consideration of the local SAR and radiation characteristics of a helical antenna using a cylindroid whole body phantom at 150 MHz
    • Yoshio Koyangi, Hiroki Kawai, Koichi Ogawa, and Koichi Ito, "Consideration of the local SAR and radiation characteristics of a helical antenna using a cylindroid whole body phantom at 150 MHz," Electronics and Communications in Japan, Part 1, 87 (1): 48-59, 2004.
    • (2004) Electronics and Communications in Japan, Part 1 , vol.87 , Issue.1 , pp. 48-59
    • Koyangi, Y.1    Kawai, H.2    Ogawa, K.3    Ito, K.4
  • 15
    • 0037389515 scopus 로고    scopus 로고
    • Electromagnetic radiation from ingested sources in the human intestine between 150 MHz and 1.2 GHz
    • April
    • L.C. Chirwa, P.A. Hammond, S. Roy, and D.R.S. Cumming, "Electromagnetic radiation from ingested sources in the human intestine between 150 MHz and 1.2 GHz," IEEE Transactions on Biomedical Engineering, vol. 50 (4): 484-492, April 2003.
    • (2003) IEEE Transactions on Biomedical Engineering , vol.50 , Issue.4 , pp. 484-492
    • Chirwa, L.C.1    Hammond, P.A.2    Roy, S.3    Cumming, D.R.S.4
  • 16
    • 33846896683 scopus 로고    scopus 로고
    • Experimental study of radiation efficiency from an ingested source inside a human body model
    • Engineering in Medicine and Biology Society
    • Y.W. Chan, Q.H. Meng, K.L. Wu, X.N. Wang, "Experimental study of radiation efficiency from an ingested source inside a human body model," Proceedings of 27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2005, pp. 7754-7757.
    • (2005) Proceedings of 27th Annual International Conference of the IEEE , pp. 7754-7757
    • Chan, Y.W.1    Meng, Q.H.2    Wu, K.L.3    Wang, X.N.4
  • 17
    • 0029957193 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: III parametric models for the dielectric spectrum of tissues
    • S. Gabriel, R.W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: III parametric models for the dielectric spectrum of tissues," Physics in Medicine and Biology, 1996, 41: 2271-2293.
    • (1996) Physics in Medicine and Biology , vol.41 , pp. 2271-2293
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 18
    • 61849129867 scopus 로고    scopus 로고
    • XFDTD Reference Manual, REMCOM Inc, 2005
    • XFDTD Reference Manual, REMCOM Inc, 2005
  • 19
    • 0033717343 scopus 로고    scopus 로고
    • Signal-processing techniques to reduce the sinusoidal steady-state error in the FDTD method
    • L. Gurel, U. Oguz, "Signal-processing techniques to reduce the sinusoidal steady-state error in the FDTD method," IEEE transactions on Antennas and Propagation, 48(4): 585-593, 2000.
    • (2000) IEEE transactions on Antennas and Propagation , vol.48 , Issue.4 , pp. 585-593
    • Gurel, L.1    Oguz, U.2
  • 20