1
-
-
0037022212
-
Importance of continuous chest compressions during cardiopulmonary resuscitation: improved outcome during a simulated single lay-rescuer scenario
-
Kern K.B., Hilwig R.W., Berg R.A., Sanders A.B., and Ewy G.A. Importance of continuous chest compressions during cardiopulmonary resuscitation: improved outcome during a simulated single lay-rescuer scenario. Circulation 105 (2002) 645-649
-
(2002)
Circulation
, vol.105
, pp. 645-649
-
-
Kern, K.B.1
Hilwig, R.W.2
Berg, R.A.3
Sanders, A.B.4
Ewy, G.A.5
-
2
-
-
0030989271
-
Adverse effects of interrupting precordial compression during cardiopulmonary resuscitation
-
Sato Y., Weil M.H., Sun S., et al. Adverse effects of interrupting precordial compression during cardiopulmonary resuscitation. Crit Care Med 25 (1997) 733-736
-
(1997)
Crit Care Med
, vol.25
, pp. 733-736
-
-
Sato, Y.1
Weil, M.H.2
Sun, S.3
-
3
-
-
0037118665
-
Adverse outcomes of interrupted precordial compression during automated defibrillation
-
Yu T., Weil M.H., Tang W., et al. Adverse outcomes of interrupted precordial compression during automated defibrillation. Circulation 106 (2002) 368-372
-
(2002)
Circulation
, vol.106
, pp. 368-372
-
-
Yu, T.1
Weil, M.H.2
Tang, W.3
-
4
-
-
28544432407
-
European Resuscitation Council guidelines for resuscitation 2005 Section 2. Adult basic life support and use of automated external defibrillators
-
Handley A.J., Koster R., Monsieurs K., Perkins G.D., Davies S., and Bossaert L. European Resuscitation Council guidelines for resuscitation 2005 Section 2. Adult basic life support and use of automated external defibrillators. Resuscitation 67 Suppl. 1 (2005) S7-23
-
(2005)
Resuscitation
, vol.67
, Issue.SUPPL. 1
-
-
Handley, A.J.1
Koster, R.2
Monsieurs, K.3
Perkins, G.D.4
Davies, S.5
Bossaert, L.6
-
5
-
-
33745101183
-
Manual chest compression vs use of an automated chest compression device during resuscitation following out-of hospital cardiac arrest: a randomized trial
-
Hallstrom A., Rea T.D., Sayre M.R., et al. Manual chest compression vs use of an automated chest compression device during resuscitation following out-of hospital cardiac arrest: a randomized trial. JAMA 295 (2006) 2620-2628
-
(2006)
JAMA
, vol.295
, pp. 2620-2628
-
-
Hallstrom, A.1
Rea, T.D.2
Sayre, M.R.3
-
6
-
-
0026673588
-
High-dose epinephrine in adult cardiac arrest
-
Stiell I.G., Hebert P.C., Weitzman B.N., et al. High-dose epinephrine in adult cardiac arrest. N Engl J Med 327 (1992) 1045-1050
-
(1992)
N Engl J Med
, vol.327
, pp. 1045-1050
-
-
Stiell, I.G.1
Hebert, P.C.2
Weitzman, B.N.3
-
7
-
-
0347086145
-
A comparison of vasopressin and epinephrine for out-of-hospital cardiopulmonary resuscitation
-
Wenzel V., Krismer A.C., Arntz H.R., Sitter H., Stadlbauer K.H., and Lindner K.H. A comparison of vasopressin and epinephrine for out-of-hospital cardiopulmonary resuscitation. N Engl J Med 350 (2004) 105-113
-
(2004)
N Engl J Med
, vol.350
, pp. 105-113
-
-
Wenzel, V.1
Krismer, A.C.2
Arntz, H.R.3
Sitter, H.4
Stadlbauer, K.H.5
Lindner, K.H.6
-
8
-
-
33751228447
-
Haemodynamic effects of adrenaline (epinephrine) depend on chest compression quality during cardiopulmonary resuscitation in pigs
-
Pytte M., Kramer-Johansen J., Eilevstjonn J., et al. Haemodynamic effects of adrenaline (epinephrine) depend on chest compression quality during cardiopulmonary resuscitation in pigs. Resuscitation 71 (2006) 369-378
-
(2006)
Resuscitation
, vol.71
, pp. 369-378
-
-
Pytte, M.1
Kramer-Johansen, J.2
Eilevstjonn, J.3
-
9
-
-
34848914317
-
A failed attempt to improve quality of out-of-hospital CPR through performance evaluation
-
Olasveengen T.M., Tomlinson A.E., Wik L., et al. A failed attempt to improve quality of out-of-hospital CPR through performance evaluation. Prehosp Emerg Care 11 (2007) 427-433
-
(2007)
Prehosp Emerg Care
, vol.11
, pp. 427-433
-
-
Olasveengen, T.M.1
Tomlinson, A.E.2
Wik, L.3
-
10
-
-
0034705961
-
-
Part 3: adult basic life support. European Resuscitation Council. Resuscitation 2000; 46:29-71.
-
Part 3: adult basic life support. European Resuscitation Council. Resuscitation 2000; 46:29-71.
-
-
-
-
11
-
-
33847259354
-
Compression force-depth relationship during out-of-hospital cardiopulmonary resuscitation
-
Tomlinson A.E., Nysaether J., Kramer-Johansen J., Steen P.A., and Dorph E. Compression force-depth relationship during out-of-hospital cardiopulmonary resuscitation. Resuscitation 72 (2007) 364-370
-
(2007)
Resuscitation
, vol.72
, pp. 364-370
-
-
Tomlinson, A.E.1
Nysaether, J.2
Kramer-Johansen, J.3
Steen, P.A.4
Dorph, E.5
-
12
-
-
12244295495
-
Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest
-
Wik L., Kramer-Johansen J., Myklebust H., et al. Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. JAMA 293 (2005) 299-304
-
(2005)
JAMA
, vol.293
, pp. 299-304
-
-
Wik, L.1
Kramer-Johansen, J.2
Myklebust, H.3
-
13
-
-
0036172471
-
Compression depth estimation for CPR quality assessment using DSP on accelerometer signals
-
Aase S.O., and Myklebust H. Compression depth estimation for CPR quality assessment using DSP on accelerometer signals. IEEE Trans Biomed Eng 49 (2002) 263-268
-
(2002)
IEEE Trans Biomed Eng
, vol.49
, pp. 263-268
-
-
Aase, S.O.1
Myklebust, H.2
-
14
-
-
0026210223
-
the 'Utstein style'. Prepared by a Task Force of Representatives from the European Resuscitation Council, American Heart Association, Heart and Stroke Foundation of Canada, Australian Resuscitation Council
-
Recommended guidelines for uniform reporting of data from out-of-hospital cardiac arrest
-
Recommended guidelines for uniform reporting of data from out-of-hospital cardiac arrest: the 'Utstein style'. Prepared by a Task Force of Representatives from the European Resuscitation Council, American Heart Association, Heart and Stroke Foundation of Canada, Australian Resuscitation Council. Resuscitation 1991;22:1-26.
-
(1991)
Resuscitation
, vol.22
, pp. 1-26
-
-
-
15
-
-
61649094270
-
Effects of simulated stomach inflation on hemodynamic and pulmonary function during cardiopulmonary resuscitation in pigs
-
Orlando
-
Paal P., Neurauter A., Loedl M., et al. Effects of simulated stomach inflation on hemodynamic and pulmonary function during cardiopulmonary resuscitation in pigs. AHA Resuscitation Science Symposium: 2007. Orlando (2007)
-
(2007)
AHA Resuscitation Science Symposium: 2007
-
-
Paal, P.1
Neurauter, A.2
Loedl, M.3
-
16
-
-
0027590961
-
Sternal force-displacement relationship during cardiopulmonary resuscitation
-
Gruben K.G., Guerci A.D., Halperin H.R., Popel A.S., and Tsitlik J.E. Sternal force-displacement relationship during cardiopulmonary resuscitation. J Biomech Eng 115 (1993) 195-201
-
(1993)
J Biomech Eng
, vol.115
, pp. 195-201
-
-
Gruben, K.G.1
Guerci, A.D.2
Halperin, H.R.3
Popel, A.S.4
Tsitlik, J.E.5
-
17
-
-
0033013157
-
Canine sternal force-displacement relationship during cardiopulmonary resuscitation
-
Gruben K.G., Halperin H.R., Popel A.S., and Tsitlik J.E. Canine sternal force-displacement relationship during cardiopulmonary resuscitation. IEEE Trans Biomed Eng 46 (1999) 788-796
-
(1999)
IEEE Trans Biomed Eng
, vol.46
, pp. 788-796
-
-
Gruben, K.G.1
Halperin, H.R.2
Popel, A.S.3
Tsitlik, J.E.4
-
18
-
-
33947523520
-
Anterior-posterior thoracic force-deflection characteristics measured during cardiopulmonary resuscitation: comparison to post-mortem human subject data
-
Arbogast K.B., Maltese M.R., Nadkarni V.M., Steen P.A., and Nysaether J.B. Anterior-posterior thoracic force-deflection characteristics measured during cardiopulmonary resuscitation: comparison to post-mortem human subject data. Stapp Car Crash J 50 (2006) 131-145
-
(2006)
Stapp Car Crash J
, vol.50
, pp. 131-145
-
-
Arbogast, K.B.1
Maltese, M.R.2
Nadkarni, V.M.3
Steen, P.A.4
Nysaether, J.B.5
-
19
-
-
0026071160
-
Dynamic behavior of excised dog rib cage: dependence on muscle
-
Kikuchi Y., Stamenovic D., and Loring S.H. Dynamic behavior of excised dog rib cage: dependence on muscle. J Appl Physiol 70 (1991) 1059-1067
-
(1991)
J Appl Physiol
, vol.70
, pp. 1059-1067
-
-
Kikuchi, Y.1
Stamenovic, D.2
Loring, S.H.3
-
20
-
-
9644264150
-
Cardiopulmonary resuscitation with a novel chest compression device in a porcine model of cardiac arrest: improved hemodynamics and mechanisms
-
Halperin H.R., Paradis N., Ornato J.P., et al. Cardiopulmonary resuscitation with a novel chest compression device in a porcine model of cardiac arrest: improved hemodynamics and mechanisms. J Am Coll Cardiol 44 (2004) 2214-2220
-
(2004)
J Am Coll Cardiol
, vol.44
, pp. 2214-2220
-
-
Halperin, H.R.1
Paradis, N.2
Ornato, J.P.3
-
21
-
-
0036890677
-
Evaluation of LUCAS, a new device for automatic mechanical compression and active decompression resuscitation
-
Steen S., Liao Q., Pierre L., Paskevicius A., and Sjoberg T. Evaluation of LUCAS, a new device for automatic mechanical compression and active decompression resuscitation. Resuscitation 55 (2002) 285-299
-
(2002)
Resuscitation
, vol.55
, pp. 285-299
-
-
Steen, S.1
Liao, Q.2
Pierre, L.3
Paskevicius, A.4
Sjoberg, T.5
-
22
-
-
9944234930
-
Chest wall injuries following cardiopulmonary resuscitation
-
Black C.J., Busuttil A., and Robertson C. Chest wall injuries following cardiopulmonary resuscitation. Resuscitation 63 (2004) 339-343
-
(2004)
Resuscitation
, vol.63
, pp. 339-343
-
-
Black, C.J.1
Busuttil, A.2
Robertson, C.3
-
23
-
-
33751241755
-
Radiological assessment of the adult chest: implications for chest compressions
-
Pickard A., Darby M., and Soar J. Radiological assessment of the adult chest: implications for chest compressions. Resuscitation 71 (2006) 387-390
-
(2006)
Resuscitation
, vol.71
, pp. 387-390
-
-
Pickard, A.1
Darby, M.2
Soar, J.3
|