메뉴 건너뛰기




Volumn 17, Issue 5, 2009, Pages 4221-4235

Ultrahigh-resolution versus speckle noise-reduction in spectral-domain optical coherence tomography

Author keywords

[No Author keywords available]

Indexed keywords

ALDEHYDES; COHERENT LIGHT; NOISE ABATEMENT; OPHTHALMOLOGY; PATHOLOGY; SPECKLE; STRAIN MEASUREMENT; TOMOGRAPHY;

EID: 61549085559     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.17.004221     Document Type: Article
Times cited : (57)

References (25)
  • 2
    • 0038618462 scopus 로고    scopus 로고
    • Performance of fourier domain vs. time domain optical coherence tomography
    • R. Leitgeb, C. K. Hitzenberger, A. F. Fercher, "Performance of fourier domain vs. time domain optical coherence tomography," Opt. Express 11, 889-894 (2003).
    • (2003) Opt. Express , vol.11 , pp. 889-894
    • Leitgeb, R.1    Hitzenberger, C.K.2    Fercher, A.F.3
  • 3
    • 0242301675 scopus 로고    scopus 로고
    • Signal to noise gain of spectral domain over time domain optical coherence tomography
    • J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, B. E. Bouma, "Signal to noise gain of spectral domain over time domain optical coherence tomography," Opt. Lett. 28, 2067-2069 (2003).
    • (2003) Opt. Lett , vol.28 , pp. 2067-2069
    • de Boer, J.F.1    Cense, B.2    Park, B.H.3    Pierce, M.C.4    Tearney, G.J.5    Bouma, B.E.6
  • 4
    • 2942703878 scopus 로고    scopus 로고
    • Sensitivity advantage of swept source and fourier domain optical coherence tomography
    • M. A. Choma, M. V. Sarunic, C. Yang, J. A. Izatt, "Sensitivity advantage of swept source and fourier domain optical coherence tomography," Opt. Express 11, 2183-2189 (2003).
    • (2003) Opt. Express , vol.11 , pp. 2183-2189
    • Choma, M.A.1    Sarunic, M.V.2    Yang, C.3    Izatt, J.A.4
  • 7
    • 0141928808 scopus 로고    scopus 로고
    • Real-time in vivo imaging by high-speed spectral optical coherence tomography
    • M. Wojtkowski, T. Bajraszewski, P. Targowski, A. Kowalczyk, "Real-time in vivo imaging by high-speed spectral optical coherence tomography," Opt. Lett. 28, 1745-1747 (2003).
    • (2003) Opt. Lett , vol.28 , pp. 1745-1747
    • Wojtkowski, M.1    Bajraszewski, T.2    Targowski, P.3    Kowalczyk, A.4
  • 14
    • 33644556796 scopus 로고    scopus 로고
    • Redefining lamellar holes and the vitreomacular interface: An ultrahigh-resolution optical coherence tomography study
    • A. J. Witkin, T. H. Ko, J. G. Fujimoto, J. S. Schuman, C. R. Baumal, A. H. Rogers, E. Reichel, J. S. Duker, "Redefining lamellar holes and the vitreomacular interface: an ultrahigh-resolution optical coherence tomography study," Ophthalmology 113, 388-397 (2006).
    • (2006) Ophthalmology , vol.113 , pp. 388-397
    • Witkin, A.J.1    Ko, T.H.2    Fujimoto, J.G.3    Schuman, J.S.4    Baumal, C.R.5    Rogers, A.H.6    Reichel, E.7    Duker, J.S.8
  • 19
    • 33750285060 scopus 로고    scopus 로고
    • V. J. Srinivasan, M. Wojtkowski, A. J. Witkin, J. S. Duker, T. H. Ko, M. Carvalho, J. S. Schuman, A. Kowalczyk, J. G. Fujimoto, High-definition and 3-dimensional imaging of macular pathologies with high-speed ultrahigh-resolution optical coherence tomography, Ophthalmology 113, 2054-2065.e3 (2006).
    • V. J. Srinivasan, M. Wojtkowski, A. J. Witkin, J. S. Duker, T. H. Ko, M. Carvalho, J. S. Schuman, A. Kowalczyk, J. G. Fujimoto, "High-definition and 3-dimensional imaging of macular pathologies with high-speed ultrahigh-resolution optical coherence tomography," Ophthalmology 113, 2054-2065.e3 (2006).
  • 20
    • 2942726534 scopus 로고    scopus 로고
    • Ultrahigh resolution optical coherence tomography imaging with a broadband superluminescent diode light source
    • T.H. Ko, D.C. Adler, JG. Fujimoto, D. Mamedov, V. Prokhorov, V. Shidlovski, S. Yakubovich, "Ultrahigh resolution optical coherence tomography imaging with a broadband superluminescent diode light source," Optics Express 12, 2112-2119 (2004).
    • (2004) Optics Express , vol.12 , pp. 2112-2119
    • Ko, T.H.1    Adler, D.C.2    Fujimoto, J.G.3    Mamedov, D.4    Prokhorov, V.5    Shidlovski, V.6    Yakubovich, S.7
  • 22
    • 12944337032 scopus 로고    scopus 로고
    • B. Sander, M. Larsen, L. Thrane L, J. L. Hougaard, T. M. Jorgensen, Enhanced optical coherence tomography imaging by multiple scan averaging, Br. J. Ophthalmol. 89, 207-212 (2005).
    • B. Sander, M. Larsen, L. Thrane L, J. L. Hougaard, T. M. Jorgensen, "Enhanced optical coherence tomography imaging by multiple scan averaging," Br. J. Ophthalmol. 89, 207-212 (2005).
  • 23
    • 44349083487 scopus 로고    scopus 로고
    • Spectral-domain optical coherence tomography with multiple B-scan averaging for enhanced imaging of retinal diseases
    • Ophthalmology 115, 1071-1078.e7
    • A. Sakamoto, M. Hangai, N. Yoshimura, "Spectral-domain optical coherence tomography with multiple B-scan averaging for enhanced imaging of retinal diseases," Ophthalmology 115, 1071-1078.e7 (2008).
    • (2008)
    • Sakamoto, A.1    Hangai, M.2    Yoshimura, N.3
  • 25
    • 61549099899 scopus 로고    scopus 로고
    • Improved visualization of polypoidal choroidal vasculopathy lesions using spectral-domain optical coherence tomography
    • Y. Ojima, M. Hangai, A. Sakamoto, A. Tsujikawa, A. Otani, H. Tamura, N. Yoshimura, "Improved visualization of polypoidal choroidal vasculopathy lesions using spectral-domain optical coherence tomography," Retina 29, 52-59 (2009).
    • (2009) Retina , vol.29 , pp. 52-59
    • Ojima, Y.1    Hangai, M.2    Sakamoto, A.3    Tsujikawa, A.4    Otani, A.5    Tamura, H.6    Yoshimura, N.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.