메뉴 건너뛰기




Volumn 50, Issue 2, 2009, Pages 170-173

Effect of radiation monitoring method and formula differences on estimated physician dose during percutaneous coronary intervention

Author keywords

Angioplasty; Catheterization; Coronary intervention; Interventional; Radiation exposure; Radiation safety

Indexed keywords

BLOOD PRESSURE; DOSIMETERS; DOSIMETRY; MONITORING; NUCLEAR REACTORS; RADIATION SHIELDING;

EID: 61449217205     PISSN: 02841851     EISSN: 16000455     Source Type: Journal    
DOI: 10.1080/02841850802616745     Document Type: Article
Times cited : (30)

References (15)
  • 1
    • 0003203252 scopus 로고    scopus 로고
    • Radiationinduced skin injury after percutaneous transluminal coronary angioplasty. Case report
    • Sovik E, Klow NE, Hellesnes J, Lykke J. Radiationinduced skin injury after percutaneous transluminal coronary angioplasty. Case report. Acta Radiol 1996; 37:305-6.
    • (1996) Acta Radiol , vol.37 , pp. 305-306
    • Sovik, E.1    Klow, N.E.2    Hellesnes, J.3    Lykke, J.4
  • 2
    • 0034146244 scopus 로고    scopus 로고
    • Patient radiation exposure during coronary angiography and intervention
    • Fransson S-G, Persliden AJ. Patient radiation exposure during coronary angiography and intervention. Acta Radiol 2000;41:142-4.
    • (2000) Acta Radiol , vol.41 , pp. 142-144
    • Fransson, S.-G.1    Persliden, A.J.2
  • 3
    • 85008998546 scopus 로고    scopus 로고
    • ICRP publication 85: Avoidance of radiation injuries from medical interventional procedures
    • International Commission on Radiological Protection, /:Publication 85
    • International Commission on Radiological Protection. ICRP publication 85: avoidance of radiation injuries from medical interventional procedures. Ann ICRP 2001;30/2:Publication 85.
    • (2001) Ann ICRP , pp. 30-32
  • 4
    • 7944234005 scopus 로고    scopus 로고
    • Does digital acquisition reduce patients' skin dose in cardiac interventional procedures? An experimental study
    • Chida K, Saito H, Zuguchi M, Shirotori K, Kumagai S, Nakayama H, et al. Does digital acquisition reduce patients' skin dose in cardiac interventional procedures? An experimental study. Am J Roentgenol 2004; 183: 1111-4.
    • (2004) Am J Roentgenol , vol.183 , pp. 1111-1114
    • Chida, K.1    Saito, H.2    Zuguchi, M.3    Shirotori, K.4    Kumagai, S.5    Nakayama, H.6
  • 5
    • 13444270562 scopus 로고    scopus 로고
    • ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular procedures: A report of the American College of Cardiology Foundation/American Heart Association American. College of Physicians Task Force on Clinical Competence and Training
    • Hirshfeld JW, Baiter S, Brinker JA, Kern MJ, Klein LW, Lindsay BD, et al. ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular procedures: a report of the American College of Cardiology Foundation/American Heart Association American. College of Physicians Task Force on Clinical Competence and Training. Circulation 2005;111:511-32.
    • (2005) Circulation , vol.111 , pp. 511-532
    • Hirshfeld, J.W.1    Baiter, S.2    Brinker, J.A.3    Kern, M.J.4    Klein, L.W.5    Lindsay, B.D.6
  • 6
    • 35148845489 scopus 로고    scopus 로고
    • Influence of the target vessel on the location and area of maximum skin dose during percutaneous coronary intervention
    • Chida K, Fuda K, Kagaya Y, Saito H, Takai Y, Kohzuki M, et al. Influence of the target vessel on the location and area of maximum skin dose during percutaneous coronary intervention. Acta Radiol 2007; 48:846-50.
    • (2007) Acta Radiol , vol.48 , pp. 846-850
    • Chida, K.1    Fuda, K.2    Kagaya, Y.3    Saito, H.4    Takai, Y.5    Kohzuki, M.6
  • 7
    • 33846026723 scopus 로고    scopus 로고
    • Patient skin dose in cardiac interventional procedures: Conventional fluoroscopy versus pulsed fluoroscopy
    • Chida K, Fuda K, Saito H, Takai Y, Takahashi S, Yamada S, et al. Patient skin dose in cardiac interventional procedures: conventional fluoroscopy versus pulsed fluoroscopy. Catheter Cardiovasc Interv 2007; 69:115-21.
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 115-121
    • Chida, K.1    Fuda, K.2    Saito, H.3    Takai, Y.4    Takahashi, S.5    Yamada, S.6
  • 8
    • 35348835424 scopus 로고    scopus 로고
    • Total entrance skin dose: An effective indicator of maximum radiation dose to the skin during percutaneous coronary intervention
    • Chida K, Kagaya Y, Saito H, Takai Y, Takahashi S, Yamada S, et al. Total entrance skin dose: an effective indicator of maximum radiation dose to the skin during percutaneous coronary intervention. Am J Roentgenol 2007;189:W224-7.
    • (2007) Am J Roentgenol , vol.189
    • Chida, K.1    Kagaya, Y.2    Saito, H.3    Takai, Y.4    Takahashi, S.5    Yamada, S.6
  • 9
    • 2642682425 scopus 로고    scopus 로고
    • Lens injuries induced by occupational exposure in nonoptimized interventional radiology laboratories
    • Vano E, Gonzalez L, Beneytez F, Moreno F. Lens injuries induced by occupational exposure in nonoptimized interventional radiology laboratories. Br J Radiol 1998;71:728-33.
    • (1998) Br J Radiol , vol.71 , pp. 728-733
    • Vano, E.1    Gonzalez, L.2    Beneytez, F.3    Moreno, F.4
  • 10
    • 0035031264 scopus 로고    scopus 로고
    • Stray radiation in the cardiac catheterisation laboratory
    • Baiter S. Stray radiation in the cardiac catheterisation laboratory. Radiat Prot Dosim 2001;94:183-8.
    • (2001) Radiat Prot Dosim , vol.94 , pp. 183-188
    • Baiter, S.1
  • 11
    • 0036147427 scopus 로고    scopus 로고
    • Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding
    • Kuon E, Schmitt M, Dahm JB. Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding. Am J Cardiol 2002;89:44-9.
    • (2002) Am J Cardiol , vol.89 , pp. 44-49
    • Kuon, E.1    Schmitt, M.2    Dahm, J.B.3
  • 12
    • 33746895109 scopus 로고    scopus 로고
    • Proper use of cineangiographic equipment and contrast agents
    • Bairn DS, Grossman W, editors, 6th edition. Philadelphia, PA: Lippincott Williams & Wilkins;
    • Bairn DS. Proper use of cineangiographic equipment and contrast agents. In: Bairn DS, Grossman W, editors. Grossman's cardiac catheterization, angiography, and intervention. 6th edition. Philadelphia, PA: Lippincott Williams & Wilkins; 2000. p. 15-34.
    • (2000) Grossman's cardiac catheterization, angiography, and intervention , pp. 15-34
    • Bairn, D.S.1
  • 13
    • 0032520325 scopus 로고    scopus 로고
    • ACC expert consensus document. Radiation safety in the practice of cardiology
    • American College of Cardiology
    • American College of Cardiology: ACC expert consensus document. Radiation safety in the practice of cardiology. J Am Coll Cardiol 1998;31:892-913.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 892-913
  • 14
    • 0029522228 scopus 로고
    • Use of personal monitors to estimate effective dose equivalent and effective dose to workers for external exposure to low-LET radiation
    • National Council on Radiation Protection and Measurements, no. 122. Maryland: NCRP; 1995
    • National Council on Radiation Protection and Measurements, 1995. Use of personal monitors to estimate effective dose equivalent and effective dose to workers for external exposure to low-LET radiation. NCRP report no. 122. Maryland: NCRP; 1995.
    • (1995) NCRP report
  • 15
    • 61449124428 scopus 로고    scopus 로고
    • The Radiation Council, Ministry of Education, Culture, Sports, Science and Technology, Japan. August 21, 2001.
    • The Radiation Council, Ministry of Education, Culture, Sports, Science and Technology, Japan. August 21, 2001.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.