메뉴 건너뛰기




Volumn 35, Issue 3, 2009, Pages 547-555

Wavefront aberrometry: Comparing and profiling higher-order aberrations produced by intraocular lenses in vitro using a physical model eye system and Hartman-Shack aberrometry

Author keywords

[No Author keywords available]

Indexed keywords

ABERROMETER; ARTICLE; CONTROLLED STUDY; IN VITRO STUDY; LENS DISEASE; LENS IMPLANT; NEW ZEALAND; OPTICAL INSTRUMENTATION; PHYSICAL MODEL; PRIORITY JOURNAL; VISUAL SYSTEM EXAMINATION; WAVEFRONT ABERROMETRY;

EID: 61349154401     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2008.11.048     Document Type: Article
Times cited : (16)

References (27)
  • 1
    • 33750084170 scopus 로고    scopus 로고
    • Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: a randomized prospective study
    • Rocha K.M., Soriano E.S., Chalita M.R., Yamada A.C., Bottós K., Bottós J., Morimoto L., and Nosé W. Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: a randomized prospective study. Am J Ophthalmol 142 (2006) 750-756
    • (2006) Am J Ophthalmol , vol.142 , pp. 750-756
    • Rocha, K.M.1    Soriano, E.S.2    Chalita, M.R.3    Yamada, A.C.4    Bottós, K.5    Bottós, J.6    Morimoto, L.7    Nosé, W.8
  • 3
    • 33644501101 scopus 로고    scopus 로고
    • Monochromatic aberrations in eyes with different intraocular lens optic designs
    • Padmanabhan P., Rao S.K., Jayasree R., Chowdhry M., and Roy J. Monochromatic aberrations in eyes with different intraocular lens optic designs. J Refract Surg 22 (2006) 172-177
    • (2006) J Refract Surg , vol.22 , pp. 172-177
    • Padmanabhan, P.1    Rao, S.K.2    Jayasree, R.3    Chowdhry, M.4    Roy, J.5
  • 4
    • 3242772864 scopus 로고    scopus 로고
    • Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses
    • Bellucci R., Morselli S., and Piers P. Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses. J Refract Surg 20 (2004) 297-306
    • (2004) J Refract Surg , vol.20 , pp. 297-306
    • Bellucci, R.1    Morselli, S.2    Piers, P.3
  • 5
    • 33744942621 scopus 로고    scopus 로고
    • Corneal and total wavefront aberrations in phakic and pseudophakic eyes after implantation of monofocal foldable intraocular lenses
    • Iseli H.P., Jankov M., Bueeler M., Wimmersberger Y., Seiler T., and Mrochen M. Corneal and total wavefront aberrations in phakic and pseudophakic eyes after implantation of monofocal foldable intraocular lenses. J Cataract Refract Surg 32 (2006) 762-771
    • (2006) J Cataract Refract Surg , vol.32 , pp. 762-771
    • Iseli, H.P.1    Jankov, M.2    Bueeler, M.3    Wimmersberger, Y.4    Seiler, T.5    Mrochen, M.6
  • 6
    • 33751102622 scopus 로고    scopus 로고
    • Comparison of higher-order aberrations and contrast sensitivity between Tecnis Z9001 and CeeOn 911A intraocular lenses: a prospective randomized study
    • Accessed December 15, 2008
    • Chen W.-R., Ye H.-H., Qian Y.-Y., Yang W.-H., and Lin Z.-H. Comparison of higher-order aberrations and contrast sensitivity between Tecnis Z9001 and CeeOn 911A intraocular lenses: a prospective randomized study. Chin Med J 119 (2006) 1779-1784. http://www.cmj.org/Periodical/PDF/200611155786880.pdf Accessed December 15, 2008
    • (2006) Chin Med J , vol.119 , pp. 1779-1784
    • Chen, W.-R.1    Ye, H.-H.2    Qian, Y.-Y.3    Yang, W.-H.4    Lin, Z.-H.5
  • 7
    • 34548713585 scopus 로고    scopus 로고
    • Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes
    • Caporossi A., Martone G., Casprini F., and Rapisarda L. Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes. J Refract Surg 23 (2007) 639-648
    • (2007) J Refract Surg , vol.23 , pp. 639-648
    • Caporossi, A.1    Martone, G.2    Casprini, F.3    Rapisarda, L.4
  • 8
    • 33751409274 scopus 로고    scopus 로고
    • Visual performance of aspherical and spherical intraocular lenses: intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations
    • Kasper T., Bühren J., and Kohnen T. Visual performance of aspherical and spherical intraocular lenses: intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations. J Cataract Refract Surg 32 (2006) 2022-2029
    • (2006) J Cataract Refract Surg , vol.32 , pp. 2022-2029
    • Kasper, T.1    Bühren, J.2    Kohnen, T.3
  • 9
    • 33846644402 scopus 로고    scopus 로고
    • Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lenses
    • Marcos S., Rosales P., Llorente L., and Jiménez-Alfaro I. Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lenses. J Cataract Refract Surg 33 (2007) 217-226
    • (2007) J Cataract Refract Surg , vol.33 , pp. 217-226
    • Marcos, S.1    Rosales, P.2    Llorente, L.3    Jiménez-Alfaro, I.4
  • 10
    • 19344373262 scopus 로고    scopus 로고
    • Effect of cataract surgery incision location and intraocular lens type on ocular aberrations
    • Pesudovs K., Dietze H., Stewart O.G., Noble B.A., and Cox M.J. Effect of cataract surgery incision location and intraocular lens type on ocular aberrations. J Cataract Refract Surg 31 (2005) 725-734
    • (2005) J Cataract Refract Surg , vol.31 , pp. 725-734
    • Pesudovs, K.1    Dietze, H.2    Stewart, O.G.3    Noble, B.A.4    Cox, M.J.5
  • 11
    • 43049138747 scopus 로고    scopus 로고
    • Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study
    • Tzelikis P.F., Akaishi L., Trindade F.C., and Boteon J.E. Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study. Am J Ophthalmol 145 (2008) 827-833
    • (2008) Am J Ophthalmol , vol.145 , pp. 827-833
    • Tzelikis, P.F.1    Akaishi, L.2    Trindade, F.C.3    Boteon, J.E.4
  • 12
    • 26844537365 scopus 로고    scopus 로고
    • Ocular higher-order wavefront aberration caused by major tilting of intraocular lens
    • Oshika T., Kawana K., Hiraoka T., and Boteon J.E. Ocular higher-order wavefront aberration caused by major tilting of intraocular lens. Am J Ophthalmol 140 (2005) 744-746
    • (2005) Am J Ophthalmol , vol.140 , pp. 744-746
    • Oshika, T.1    Kawana, K.2    Hiraoka, T.3    Boteon, J.E.4
  • 13
    • 33846827211 scopus 로고    scopus 로고
    • Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration
    • Oshika T., Sugita G., Miyata K., Tokunaga T., Samejima T., Okamoto C., and Ishii Y. Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration. Br J Ophthalmol 91 (2007) 185-188
    • (2007) Br J Ophthalmol , vol.91 , pp. 185-188
    • Oshika, T.1    Sugita, G.2    Miyata, K.3    Tokunaga, T.4    Samejima, T.5    Okamoto, C.6    Ishii, Y.7
  • 14
    • 4944255688 scopus 로고    scopus 로고
    • Influence of intraocular lens tilt and decentration on wavefront aberrations
    • Taketani F., Matsuura T., Yukawa E., and Hara Y. Influence of intraocular lens tilt and decentration on wavefront aberrations. J Cataract Refract Surg 30 (2004) 2158-2162
    • (2004) J Cataract Refract Surg , vol.30 , pp. 2158-2162
    • Taketani, F.1    Matsuura, T.2    Yukawa, E.3    Hara, Y.4
  • 16
    • 0036743484 scopus 로고    scopus 로고
    • Standards for reporting the optical aberrations of eyes; VSIA Standards Taskforce Members
    • Thibos L.N., Applegate R.A., Schwiegerling J.T., and Webb R. Standards for reporting the optical aberrations of eyes; VSIA Standards Taskforce Members. J Refract Surg 18 (2002) S652-S660
    • (2002) J Refract Surg , vol.18
    • Thibos, L.N.1    Applegate, R.A.2    Schwiegerling, J.T.3    Webb, R.4
  • 17
    • 33748324384 scopus 로고    scopus 로고
    • R Development Core Team, R Foundation for Statistical Computing, Vienna, Austria Accessed December 15, 2008
    • R Development Core Team. R. A Language and Environment for Statistical Computing (2006), R Foundation for Statistical Computing, Vienna, Austria. http://cran.r-project.org/doc/manuals/refman.pdf Accessed December 15, 2008
    • (2006) R. A Language and Environment for Statistical Computing
  • 19
    • 33846608607 scopus 로고    scopus 로고
    • Spherical aberration and coma with an aspherical and a spherical intraocular lens in normal age-matched eyes
    • Bellucci R., Morselli S., and Pucci V. Spherical aberration and coma with an aspherical and a spherical intraocular lens in normal age-matched eyes. J Cataract Refract Surg 33 (2007) 203-209
    • (2007) J Cataract Refract Surg , vol.33 , pp. 203-209
    • Bellucci, R.1    Morselli, S.2    Pucci, V.3
  • 20
    • 33644669989 scopus 로고    scopus 로고
    • Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameter
    • Kasper T., Bühren J., and Kohnen T. Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameter. J Cataract Refract Surg 32 (2006) 78-84
    • (2006) J Cataract Refract Surg , vol.32 , pp. 78-84
    • Kasper, T.1    Bühren, J.2    Kohnen, T.3
  • 21
    • 33750598060 scopus 로고    scopus 로고
    • Predicting the optical performance of eyes implanted with IOLs to correct spherical aberration
    • Accessed December 15, 2008
    • Tabernero J., Piers P., Benito A., Redondo M., and Artal P. Predicting the optical performance of eyes implanted with IOLs to correct spherical aberration. Invest Ophthalmol Vis Sci 47 (2006) 4651-4658. http://www.iovs.org/cgi/reprint/47/10/4651 Accessed December 15, 2008
    • (2006) Invest Ophthalmol Vis Sci , vol.47 , pp. 4651-4658
    • Tabernero, J.1    Piers, P.2    Benito, A.3    Redondo, M.4    Artal, P.5
  • 22
    • 1842424447 scopus 로고    scopus 로고
    • High-order aberrations in pseudophakia with different intraocular lenses
    • Vilarrodona L., Barrett G.D., and Johnson B. High-order aberrations in pseudophakia with different intraocular lenses. J Cataract Refract Surg 30 (2004) 571-575
    • (2004) J Cataract Refract Surg , vol.30 , pp. 571-575
    • Vilarrodona, L.1    Barrett, G.D.2    Johnson, B.3
  • 23
    • 40949105235 scopus 로고    scopus 로고
    • Wavefront measurements of diffractive and refractive multifocal intraocular lenses in an artificial eye
    • Campbell C.E. Wavefront measurements of diffractive and refractive multifocal intraocular lenses in an artificial eye. J Refract Surg 24 (2008) 308-311
    • (2008) J Refract Surg , vol.24 , pp. 308-311
    • Campbell, C.E.1
  • 24
  • 26
    • 0037046566 scopus 로고    scopus 로고
    • Imperfect optics may be the eye's defense against chromatic blur
    • McLellan J.S., Marcos S., Prieto P.M., and Burns S.A. Imperfect optics may be the eye's defense against chromatic blur. Nature 417 (2002) 174-176
    • (2002) Nature , vol.417 , pp. 174-176
    • McLellan, J.S.1    Marcos, S.2    Prieto, P.M.3    Burns, S.A.4
  • 27
    • 45249108838 scopus 로고    scopus 로고
    • Contrast sensitivity and higher order aberrations in eyes implanted with AcrySof IQ SN60WF and AcrySof SN60AT intraocular lenses
    • Awwad S.T., Warmerdam D., Bowman R.W., Dwarakanathan S., Cavanagh H.D., and McCulley J.P. Contrast sensitivity and higher order aberrations in eyes implanted with AcrySof IQ SN60WF and AcrySof SN60AT intraocular lenses. J Refract Surg 24 (2008) 619-625
    • (2008) J Refract Surg , vol.24 , pp. 619-625
    • Awwad, S.T.1    Warmerdam, D.2    Bowman, R.W.3    Dwarakanathan, S.4    Cavanagh, H.D.5    McCulley, J.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.