메뉴 건너뛰기




Volumn 74, Issue 3, 2009, Pages 315-321

Doping control analysis of trenbolone and related compounds using liquid chromatography-tandem mass spectrometry

Author keywords

Anabolic steroid; Doping; Liquid chromatography; Mass spectrometry; Sport

Indexed keywords

17 KETOTRENBOLONE; 17ALPHA TRENBOLONE; ALTRENOGEST; ANABOLIC AGENT; ETHYLTRENBOLONE; ILLICIT DRUG; METHYLTRENBOLONE; PROPYLTRENBOLONE; PROTON; TRENBOLONE; UNCLASSIFIED DRUG;

EID: 61349147115     PISSN: 0039128X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.steroids.2008.10.004     Document Type: Article
Times cited : (29)

References (27)
  • 1
    • 19944374132 scopus 로고    scopus 로고
    • Mass spectrometry in doping control analysis
    • Thevis M., and Schänzer W. Mass spectrometry in doping control analysis. Curr Org Chem 9 (2005) 825-848
    • (2005) Curr Org Chem , vol.9 , pp. 825-848
    • Thevis, M.1    Schänzer, W.2
  • 2
    • 34547237752 scopus 로고    scopus 로고
    • Current role of LC-MS(/MS) in doping control
    • Thevis M., and Schänzer W. Current role of LC-MS(/MS) in doping control. Anal Bioanal Chem 388 (2007) 1351-1358
    • (2007) Anal Bioanal Chem , vol.388 , pp. 1351-1358
    • Thevis, M.1    Schänzer, W.2
  • 3
    • 33845980567 scopus 로고    scopus 로고
    • Mass spectrometry in sports drug testing: structure characterization and analytical assays
    • Thevis M., and Schänzer W. Mass spectrometry in sports drug testing: structure characterization and analytical assays. Mass Spectrom Rev 26 (2007) 79-107
    • (2007) Mass Spectrom Rev , vol.26 , pp. 79-107
    • Thevis, M.1    Schänzer, W.2
  • 4
    • 0026205056 scopus 로고
    • The analysis of trenbolone and the human urinary metabolites of trenbolone acetate by gas chromatography/mass spectrometry and gas chromatography/tandem mass spectrometry
    • de Boer D., Bernal M.E.G., van Ooyen R.D., and Maes R.A.A. The analysis of trenbolone and the human urinary metabolites of trenbolone acetate by gas chromatography/mass spectrometry and gas chromatography/tandem mass spectrometry. Biol Mass Spectrom 20 (1991) 459-466
    • (1991) Biol Mass Spectrom , vol.20 , pp. 459-466
    • de Boer, D.1    Bernal, M.E.G.2    van Ooyen, R.D.3    Maes, R.A.A.4
  • 6
    • 0036773324 scopus 로고    scopus 로고
    • Fast screening of anabolic steroids and other banned doping substances in human urine by gas chromatography/tandem mass spectrometry
    • Marcos J., Pascual J.A., de la Torre X., and Segura J. Fast screening of anabolic steroids and other banned doping substances in human urine by gas chromatography/tandem mass spectrometry. J Mass Spectrom 37 (2002) 1059-1073
    • (2002) J Mass Spectrom , vol.37 , pp. 1059-1073
    • Marcos, J.1    Pascual, J.A.2    de la Torre, X.3    Segura, J.4
  • 7
    • 34248225011 scopus 로고    scopus 로고
    • Analysis of synthetic 19-norsteroids trenbolone, tetrahydrogestrinone and gestrinone by gas chromatography-mass spectrometry
    • Marques M.A., Pereira H.M., Padilha M.C., and de Aquino Neto F.R. Analysis of synthetic 19-norsteroids trenbolone, tetrahydrogestrinone and gestrinone by gas chromatography-mass spectrometry. J Chromatogr A 1150 (2007) 215-225
    • (2007) J Chromatogr A , vol.1150 , pp. 215-225
    • Marques, M.A.1    Pereira, H.M.2    Padilha, M.C.3    de Aquino Neto, F.R.4
  • 8
    • 37649013598 scopus 로고    scopus 로고
    • Application of fast gas chromatography/mass spectrometry for the rapid screening of synthetic anabolic steroids and other drugs in anti-doping analysis
    • Mazzarino M., Orengia M., and Botre F. Application of fast gas chromatography/mass spectrometry for the rapid screening of synthetic anabolic steroids and other drugs in anti-doping analysis. Rapid Commun Mass Spectrom 21 (2007) 4117-4124
    • (2007) Rapid Commun Mass Spectrom , vol.21 , pp. 4117-4124
    • Mazzarino, M.1    Orengia, M.2    Botre, F.3
  • 9
    • 23244446577 scopus 로고    scopus 로고
    • Screening for unknown synthetic steroids in human urine by liquid chromatography-tandem mass spectrometry
    • Thevis M., Geyer H., Mareck U., and Schänzer W. Screening for unknown synthetic steroids in human urine by liquid chromatography-tandem mass spectrometry. J Mass Spectrom 40 (2005) 955-962
    • (2005) J Mass Spectrom , vol.40 , pp. 955-962
    • Thevis, M.1    Geyer, H.2    Mareck, U.3    Schänzer, W.4
  • 10
    • 61349143668 scopus 로고    scopus 로고
    • Schänzer W., Geyer H., Gotzmann A., and Mareck U. (Eds), Sport&Buch Strauß, Cologne
    • Guddat S., Schänzer W., Wachsmuth P., and Thevis M. In: Schänzer W., Geyer H., Gotzmann A., and Mareck U. (Eds). Recent advances in doping analysis vol. 15 (2007), Sport&Buch Strauß, Cologne 397-400
    • (2007) Recent advances in doping analysis , vol.15 , pp. 397-400
    • Guddat, S.1    Schänzer, W.2    Wachsmuth, P.3    Thevis, M.4
  • 11
    • 33646767075 scopus 로고    scopus 로고
    • Screening for anabolic steroids in doping analysis by liquid chromatography/electrospray ion trap mass spectrometry
    • Deventer K., Eenoo P.V., and Delbeke F.T. Screening for anabolic steroids in doping analysis by liquid chromatography/electrospray ion trap mass spectrometry. Biomed Chromatogr 20 (2006) 429-433
    • (2006) Biomed Chromatogr , vol.20 , pp. 429-433
    • Deventer, K.1    Eenoo, P.V.2    Delbeke, F.T.3
  • 12
    • 34748883693 scopus 로고    scopus 로고
    • Development and validation of a qualitative screening method for the detection of exogenous anabolic steroids in urine by liquid chromatography-tandem mass spectrometry
    • Pozo O.J., Van Eenoo P., Deventer K., and Delbeke F.T. Development and validation of a qualitative screening method for the detection of exogenous anabolic steroids in urine by liquid chromatography-tandem mass spectrometry. Anal Bioanal Chem 389 (2007) 1209-1224
    • (2007) Anal Bioanal Chem , vol.389 , pp. 1209-1224
    • Pozo, O.J.1    Van Eenoo, P.2    Deventer, K.3    Delbeke, F.T.4
  • 14
    • 18144423935 scopus 로고    scopus 로고
    • Screening of anabolic steroids in horse urine by liquid chromatography-tandem mass spectrometry
    • Yu N.H., Ho E.N., Leung D.K., and Wan T.S. Screening of anabolic steroids in horse urine by liquid chromatography-tandem mass spectrometry. J Pharm Biomed Anal 37 (2005) 1031-1038
    • (2005) J Pharm Biomed Anal , vol.37 , pp. 1031-1038
    • Yu, N.H.1    Ho, E.N.2    Leung, D.K.3    Wan, T.S.4
  • 16
    • 0017170098 scopus 로고
    • Assay of androgen binding sites by exchange with methyltrienolone (R 1881)
    • Bonne C., and Raynaud J.P. Assay of androgen binding sites by exchange with methyltrienolone (R 1881). Steroids 27 (1976) 497-507
    • (1976) Steroids , vol.27 , pp. 497-507
    • Bonne, C.1    Raynaud, J.P.2
  • 17
    • 0016774967 scopus 로고
    • Methyltrienolone, a specific ligand for cellular androgen receptors
    • Bonne C., and Raynaud J.P. Methyltrienolone, a specific ligand for cellular androgen receptors. Steroids 26 (1975) 227-232
    • (1975) Steroids , vol.26 , pp. 227-232
    • Bonne, C.1    Raynaud, J.P.2
  • 18
    • 0013925594 scopus 로고
    • Liver toxicity of a new anabolic agent: methyltrienolone (17-alpha-methyl-4,9, 11-estratriene-17 beta-ol-3-one)
    • Kruskemper H.L., and Noell G. Liver toxicity of a new anabolic agent: methyltrienolone (17-alpha-methyl-4,9, 11-estratriene-17 beta-ol-3-one). Steroids 8 (1966) 13-24
    • (1966) Steroids , vol.8 , pp. 13-24
    • Kruskemper, H.L.1    Noell, G.2
  • 19
    • 18344374877 scopus 로고    scopus 로고
    • Characterization of chemically modified steroids for doping control purposes by electrospray ionization tandem mass spectrometry
    • Thevis M., Opfermann G., Bommerich U., and Schänzer W. Characterization of chemically modified steroids for doping control purposes by electrospray ionization tandem mass spectrometry. J Mass Spectrom 40 (2005) 494-502
    • (2005) J Mass Spectrom , vol.40 , pp. 494-502
    • Thevis, M.1    Opfermann, G.2    Bommerich, U.3    Schänzer, W.4
  • 20
    • 39849109297 scopus 로고    scopus 로고
    • Schänzer W., Geyer H., Gotzmann A., and Mareck U. (Eds), Sport&Buch Strauß, Cologne
    • Thevis M., Geyer H., Mareck U., and Schänzer W. In: Schänzer W., Geyer H., Gotzmann A., and Mareck U. (Eds). Recent advances in doping analysis vol. 13 (2005), Sport&Buch Strauß, Cologne 147-155
    • (2005) Recent advances in doping analysis , vol.13 , pp. 147-155
    • Thevis, M.1    Geyer, H.2    Mareck, U.3    Schänzer, W.4
  • 24
    • 67649498509 scopus 로고    scopus 로고
    • World Anti-Doping Agency, 15.02
    • World Anti-Doping Agency. Laboratory statistics. ; 2008 [15.02.2008].
    • (2008) Laboratory statistics


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.