메뉴 건너뛰기




Volumn 36, Issue 3, 2009, Pages 904-907

Calculation of the biological effective dose for piecewise defined dose-rate fits

Author keywords

[No Author keywords available]

Indexed keywords

PATIENT MONITORING; PATIENT TREATMENT;

EID: 61349131278     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3070587     Document Type: Article
Times cited : (26)

References (8)
  • 1
    • 14844354088 scopus 로고    scopus 로고
    • Patient-specific dosimetry in predicting renal toxicity with (90)Y-DOTATOC: Relevance of kidney volume and dose rate in finding a dose-effect relationship
    • 0161-5505
    • R. Barone, F. Borson-Chazot, R. Valkema, S. Walrand, F. Chauvin, L. Gogou, L. K. Kvols, E. P. Krenning, F. Jamar, and S. Pauwels, " Patient-specific dosimetry in predicting renal toxicity with (90)Y-DOTATOC: relevance of kidney volume and dose rate in finding a dose-effect relationship.," J. Nucl. Med. 46, 99S-106S (2005). 0161-5505
    • (2005) J. Nucl. Med. , vol.46
    • Barone, R.1    Borson-Chazot, F.2    Valkema, R.3    Walrand, S.4    Chauvin, F.5    Gogou, L.6    Kvols, L.K.7    Krenning, E.P.8    Jamar, F.9    Pauwels, S.10
  • 2
    • 40049084212 scopus 로고    scopus 로고
    • Extension of the biological effective dose to the MIRD schema and possible implications in radionuclide therapy dosimetry
    • 0094-2405 10.1118/1.2836421.
    • S. Baechler, R. F. Hobbs, A. R. Prideaux, R. L. Wahl, and G. Sgouros, " Extension of the biological effective dose to the MIRD schema and possible implications in radionuclide therapy dosimetry.," Med. Phys. 0094-2405 10.1118/1.2836421 35, 1123-1134 (2008).
    • (2008) Med. Phys. , vol.35 , pp. 1123-1134
    • Baechler, S.1    Hobbs, R.F.2    Prideaux, A.R.3    Wahl, R.L.4    Sgouros, G.5
  • 3
    • 0028081071 scopus 로고
    • Application of the linear-quadratic model to radioimmunotherapy: Further support for the advantage of longer-lived radionuclides
    • 0161-5505
    • R. W. Howell, M. S. Goddu, and D. V. Rao, " Application of the linear-quadratic model to radioimmunotherapy: Further support for the advantage of longer-lived radionuclides.," J. Nucl. Med. 35, 1861-1869 (1994). 0161-5505
    • (1994) J. Nucl. Med. , vol.35 , pp. 1861-1869
    • Howell, R.W.1    Goddu, M.S.2    Rao, D.V.3
  • 4
    • 85092677650 scopus 로고    scopus 로고
    • Ph.D. thesis, University of Duisburg-Essen.
    • 124I-Quantifizierung.," Ph.D. thesis, University of Duisburg-Essen, 2009.
    • (2009) 124I-Quantifizierung
    • Jentzen, W.1
  • 5
    • 34250345988 scopus 로고    scopus 로고
    • Three-dimensional radiobiologic dosimetry: Application of radiobiologic modeling to patient-specific 3-dimensional imaging-based internal dosimetry
    • 0161-5505 10.2967/jnumed.106.038000.
    • A. R. Prideaux, H. Song, R. F. Hobbs, B. He, E. C. Frey, P. W. Ladenson, R. L. Wahl, and G. Sgouros, " Three-dimensional radiobiologic dosimetry: application of radiobiologic modeling to patient-specific 3-dimensional imaging-based internal dosimetry.," J. Nucl. Med. 0161-5505 10.2967/jnumed.106.038000 48, 1008-1016 (2007).
    • (2007) J. Nucl. Med. , vol.48 , pp. 1008-1016
    • Prideaux, A.R.1    Song, H.2    Hobbs, R.F.3    He, B.4    Frey, E.C.5    Ladenson, P.W.6    Wahl, R.L.7    Sgouros, G.8
  • 6
    • 0026065812 scopus 로고
    • Application of the linear-quadratic model with incomplete repair to radionuclide directed therapy
    • 0007-1285
    • W. T. Millar, " Application of the linear-quadratic model with incomplete repair to radionuclide directed therapy.," Br. J. Radiol. 64, 242-251 (1991). 0007-1285
    • (1991) Br. J. Radiol. , vol.64 , pp. 242-251
    • Millar, W.T.1
  • 7
    • 0031803003 scopus 로고    scopus 로고
    • The linear-quadratic model and most other common radiobiological models result in similar predictions of time-dose relationships
    • 0033-7587 10.2307/3579648.
    • D. J. Brenner, L. R. Hlatky, P. J. Hahnfeldt, Y. Huang, and R. K. Sachs, " The linear-quadratic model and most other common radiobiological models result in similar predictions of time-dose relationships.," Radiat. Res. 0033-7587 10.2307/3579648 150, 83-91 (1998).
    • (1998) Radiat. Res. , vol.150 , pp. 83-91
    • Brenner, D.J.1    Hlatky, L.R.2    Hahnfeldt, P.J.3    Huang, Y.4    Sachs, R.K.5
  • 8
    • 0021812109 scopus 로고
    • The application of the linear-quadratic dose-effect equation to fractionated and protracted radiotherapy
    • 0007-1285 10.1016/0167-8140(92)90244-O.
    • R. G. Dale, " The application of the linear-quadratic dose-effect equation to fractionated and protracted radiotherapy.," Br. J. Radiol. 0007-1285 10.1016/0167-8140(92)90244-O 58, 515-528 (1985).
    • (1985) Br. J. Radiol. , vol.58 , pp. 515-528
    • Dale, R.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.